Xin-Yan Guo

Dr. Xin-Yan Guo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2016 in International Journal of Polymer Science
Verified
Journal Article
Open access
PDF file
Xiaohong ZhengXiaohong Zheng
Xiaohong Zheng
PHPei-Yan Huang
Pei-Yan Huang
XGXin-Yan Guo
Xin-Yan Guo
JHJ. L. Huang
J. L. Huang
As the technique of fiber-reinforced polymer (FRP) composite material strengthened reinforced concrete structures is widely used in the field of civil engineering, durability of the strengthened structures has attracted more attention in recent years. Hygrothermal environment has an adverse effect on the bond behavior of the interface between FRP and concrete. This paper focuses on the bond durability of carbon fiber laminate- (CFL-) concrete interface in hygrothermal condition which simulates the climate characteristic in South China. Twenty 100 mm × 100 mm × 720 mm specimens were divided into 6 groups based on different temperature and humidity. After pretreatment in hygrothermal environment, the specimens were tested using double shear method. Strain gauges bonded along the CFL surface and linear variation displacement transducers (LVDTs) were used to measure longitudinal strains and slip of the interface. Failure mode, ultimate capacity, load-deflection relationship, and relative slip were analyzed. The bond behavior of FRP-concrete interface under hygrothermal environment was studied. Results show that the ultimate bearing capacity of the interface reduced after exposure to hygrothermal environments. The decreasing ranges were up to 27.9% after exposure at high temperature and humidity (60°C, 95% RH). The maximum strains (εmax) of the specimens pretreated decreased obviously which indicated decay of the bond behavior after exposure to the hygrothermal environment.

26 December 2023 in International Journal of Fatigue
Verified
Journal Article
Closed access
JBJiahao Bai
Jiahao Bai
YYYi Yang
Yi Yang
PHPeiyan Huang
Peiyan Huang
XGXin-Yan Guo
Xin-Yan Guo
ZCZhanbiao Chen
Zhanbiao Chen
WLWen Li
Wen Li

21 April 2020 in Polymers
Verified
Journal Article
Open access
PDF file
XGXin-Yan Guo
Xin-Yan Guo
SSShenyunhao Shu
Shenyunhao Shu
YWYilin Wang
Yilin Wang
PHPei-Yan Huang
Pei-Yan Huang
Jia-Xiang LinJia-Xiang Lin
Jia-Xiang Lin
Yong-Chang GuoYong-Chang Guo
Yong-Chang Guo
Subtropical natural exposure may significantly affect the bonding behavior of fiber reinforced polymer (FRP) externally bonded to concrete. To study the effect of subtropical natural climates on the FRP-concrete interface, natural exposure tests and an analytical approach were carried out on specimens externally bonded with carbon fiber reinforced polymer (CFRP) and basalt fiber reinforced polymer (BFRP). The bilinear bond stress-slip relationships for different exposure periods were derived from the experimental results of the strengthened reinforced concrete (RC) beams. Based on these bond-slip relationships, the full-range behavior of shear stress along the bond length and debonding load can be obtained through the analytical solution. The testing and numerical results showed that subtropical natural exposure can greatly affect the bond behavior of CFRP-concrete and BFRP-concrete interfaces in the early exposure period. In the late exposure period, the bond behavior was basically stable. With the increase of exposure time, the position of maximum shear stress tended to move backward, which indicated that the behavior of the FRP-concrete interface was weakened by natural exposure. Compared to the CFRP-concrete interface, subtropical natural exposure has greater influence on the bond behavior of the BFRP-concrete interface.

13 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
XGXin-Yan Guo
Xin-Yan Guo
ZWZuodong Wu
Zuodong Wu
YYYi Yang
Yi Yang
JBJiahao Bai
Jiahao Bai
QZQianziyang Zhou
Qianziyang Zhou
The bonding interface between the CFRP and the steel plate is the weak link of CFRP-strengthened steel structures. This paper studies the bond–slip relationship of the CFRP–steel interface by experiments and numerical tests. First, a series of double-strap experiments on a CFRP-strengthened steel plate are carried out. The results show that the maximum shear stress of the bonding interface of the Q345B specimen is larger than that of the X100 specimen. The initial slip and maximum slip become larger as the thickness of the bonding interface becomes larger. Finite element analysis of the above tests is carried out; we introduce the maximum stress criterion to simulate the bonding interface, which assumes that when the nominal stress of the material reaches the maximum nominal stress of damage, the material begins to damage. The FE model established has proved very effective for analyzing the bond characteristics of CFRP-strengthened steel plates. Finally, a verification test was carried out, using an FE analysis to verify the accuracy of the modified equations; the results prove that the results of the modified equations are in good agreement with the numerical results and experiment results, which verifies the effectiveness of the equations.

13 January 2019 in Polymers
Verified
Journal Article
Open access
PDF file
XGXin-Yan Guo
Xin-Yan Guo
YWYi-Lin Wang
Yi-Lin Wang
PHPei-Yan Huang
Pei-Yan Huang
Xiaohong ZhengXiaohong Zheng
Xiaohong Zheng
YYYi Yang
Yi Yang
With the prestressed carbon fiber reinforced polymer (CFRP) strengthening technique widely used in reinforced concrete (RC) structures, it is more and more important to study the fatigue performance of RC structures. Since the fracture of a tensile steel bar at the main cracked section is the leading reason for the failure of RC beams reinforced by prestressed CFRP, a fatigue life prediction model of RC beams reinforced by prestressed CFRP was developed based on an accumulative damage model. Moreover, gradual degradation of the performance of the concrete was considered in the fatigue life prediction model. An experimental study was also conducted to research the fatigue behavior of RC beams reinforced by prestressed or non-prestressed carbon fiber laminate (CFL). During the tests, fatigue crack patterns were captured using a digital image correlation (DIC) technique, and the fatigue lives of a total of 30 beams were recorded. The results showed that the predicted main crack propagation curves and the fatigue lives were close to the experimental data. This study also exhibited that the prestressed CFRP could reduce the stress of main steel bars in RC beams and effectively improve the fatigue performance of the RC beams.

20 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
BLBaojun Li
Baojun Li
LZLingkai Zeng
Lingkai Zeng
XGXin-Yan Guo
Xin-Yan Guo
YWYilin Wang
Yilin Wang
ZDZhiheng Deng
Zhiheng Deng
The advantages of using prestressed carbon fiber reinforced polymer (CFRP) for strengthening and retrofitting structures have been reported in recent years. In this regard, most of the studies on prestressed CFRP technique have been carried out in the laboratory test with small-scale and no damage (reinforced concrete) RC beam. However, the real structures that need to be retrofitted in service are often degraded or damaged due to early cracking. This paper aims at studying the effect of prestressed CFRP method on full-scale and damaged RC beams. The damaged levels of four full-scale damaged hollow RC beams taken from an old bridge were evaluated. One damaged beam was tested to check the residual capacity, and the other three were strengthened with prestressed composite strengthened CFRP and steel-carbon fiber reinforced polymer (SCFRP). The flexural behavior of non-strengthened and prestressed strengthened beams was investigated. During the experiments, the failure modes, deflection, yield and ultimate load, strains of concrete, steel reinforcements, and SCFRP were measured and analyzed. The results showed that the stiffness at the elastic stage was increased by 64.9%, 66.9%, and 67.1% after strengthened by SCFRP with 30%, 40%, and 60% prestressing level. Moreover, the ultimate load of damaged hollow RC beams were improved by 19.53%, 21.82%, and 31.9%, respectively. The flexural behavior of the severely damaged RC beam with strength reduction coefficient of 0.65 can be recovered after being strengthened by SCFRP with 40% prestressing levels. Meanwhile, SCFRP-concrete interface debonding failure occurred when the prestressing level exceed 60%, and the characteristics of brittle failure became more evident with increased prestressing level of the SCFRP.