Rongrong Zhang

Ms. Rongrong Zhang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RZRongrong Zhang
Rongrong Zhang
SWSHUO WANG
SHUO WANG
TLTeng Long
Teng Long
Jian QiuJian Qiu
Jian Qiu
Kefu LiuKefu Liu
Kefu Liu
Hui ZhaoHui Zhao
Hui Zhao
The parasitic capacitance of magnetic components, i.e., inductors and transformers, are crucial, because it dominates the high-frequency impedance, causes voltage / current spikes, and arouses electromagnetic interference issues. The existing methods characterize capacitance from all five parts (turn-to-turn, layer-to-layer, winding-to-magnetic core, winding-to-electrostatic screen, and interwinding). However, the calculated results are always less than the measured capacitance, especially for the inductors with few winding turns. This article discovers another mechanism of the parasitic capacitance caused by d B /d t . It points out that a time-varying magnetic field also generates an electric field, which leads to parasitic capacitance, and proves that this capacitance dominates the first resonant frequency (denoted by fR ) of the inductors with few winding turns. The factors related to the capacitance and the fR are analyzed. The proposed theoretical analysis is validated by numerous simulations and experimental results. All the simulations are included in the multimedia folder.

1 October 2020 in Journal of Proteomics
Verified
Journal Article
Closed access
JHJing Han
Jing Han
YPYiqing Pan
Yiqing Pan
YGYong Gu
Yong Gu
XXXiaoyan Xu
Xiaoyan Xu
RZRan Zhao
Ran Zhao
SRShifang Ren
Shifang Ren

4 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RZRongrong Zhang
Rongrong Zhang
AIAtif Iqbal
Atif Iqbal
SWSHUO WANG
SHUO WANG
Chaoqiang JiangChaoqiang Jiang
Chaoqiang Jiang
TLTeng Long
Teng Long
Hui ZhaoHui Zhao
Hui Zhao
The first resonant frequency ( fR ) is usually believed to be mainly determined by material properties. Therefore, nanocrystalline common-mode inductors are typically used at frequencies below several tens of kilohertz. This letter proposes an inductor with a 2-D core and origami winding to increase the first fR without changing the material. Especially, for nanocrystalline, the proposed 2-D structure increases the first fR to over 10 MHz and preserves the high permeability of nanocrystalline. Furthermore, this proposed 2-D structure also sharply reduces near-field radiation and enhances heat dissipation. Applying the proposed inductor in an electromagnetic interference filter with a boost converter verifies the effectiveness of our proposed inductor.

27 August 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RZRongrong Zhang
Rongrong Zhang
Chaoqiang JiangChaoqiang Jiang
Chaoqiang Jiang
SWSHUO WANG
SHUO WANG
TLTeng Long
Teng Long
AIAtif Iqbal
Atif Iqbal
Hui ZhaoHui Zhao
Hui Zhao
Multilayer ceramic capacitors (MLCCs) are widely used in power electronics. Because paraelectric and ferroelectric material are nonmagnetic dielectrics, B-field effects are typically ignored in datasheets and design consideration. This letter reveals a significant, previously undocumented phenomenon: B-fields cause substantial high-frequency impedance variation in MLCCs, with observed changes exceeding 43% under B-fields up to 491 mT. Supplementary material includes all the design files for the measurement kit and all the raw data to ensure reproducibility. Raman spectroscopy and microstructure were employed to characterize the material composition and physical structure of the MLCCs.

27 May 2026 in Electronics
Verified
Journal Article
Open access
PDF file
DCDachuan Chen
Dachuan Chen
SSShiyi Shao
Shiyi Shao
SDShuai Ding
Shuai Ding
Hui ZhaoHui Zhao
Hui Zhao
YDYi Du
Yi Du
RZRongrong Zhang
Rongrong Zhang
SiC MOSFETs suffer from severe EMI issues due to their high dv/dt and di/dt values as well as the reduced coupling length resulting from their compact design. Conventional magnetic shielding suffers from three major limitations: susceptibility to magnetic saturation, restrictions at high frequencies, and extra parasitic inductance introduced by the shielding material itself. This paper proposes a method that uses eddy currents to mitigate the near-field magnetic radiation. By wrapping the system in an external copper layer without affecting system layout or wiring, external radiation is reduced by 10 times, removing the possibility of magnetic saturation, and reducing parasitic inductance by 10 percent. Compared to traditional magnetic shielding, this solution is cost-effective, and offers enhanced reliability and performance.

13 November 2026 in Electronics
Verified
Journal Article
Open access
PDF file
XLXiaobing Lao
Xiaobing Lao
ZJZhaohui Jin
Zhaohui Jin
JXJingying Xie
Jingying Xie
LYLiqin Yan
Liqin Yan
Cheng WangCheng Wang
Cheng Wang
Hui ZhaoHui Zhao
Hui Zhao
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.