Giovanni F. Solitro

Dr. Giovanni F. Solitro

LSU Health Sciences Center - Shreveport, Shreveport, United States
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Spine Deformity
Verified
Journal Article
Closed access
FAFarid Amirouche
Farid Amirouche
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
BMBrenden P. Magnan
Brenden P. Magnan

12 April 2019 in International Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
KWKeith Whitlock
Keith Whitlock
FAFarid Amirouche
Farid Amirouche
AMAnkit I. Mehta
Ankit I. Mehta
AMAnnie Mcdonnell
Annie Mcdonnell
Background Transpedicular screw insertion has become widely accepted for the correction of spinal deformity as well as degenerative and traumatic injury, but adoption of this technique has remained less widespread in the thoracic compared to the lumbar spine. This is thought to be associated with the relative technical difficulty of screw insertion into the narrower widths of the thoracic pedicles and the neurologic and mechanical risks associated with breach of the pedicle wall. The surgical decision making involves determining the appropriate sized screw for maximum fixation strength while simultaneously respecting the structural integrity of the vertebral pedicles to prevent a breach and provide better fixation. This paper presents a systematic review of criteria for thoracic pedicle screw diameter (SD) selection in order to orient inexperienced surgeons on the impact of this selection on pedicle breaching and fixation strength. Methods We performed a systematic literature review focused on studies reporting SD selection in relation to pedicle dimensions, measures of fixation strength, and breach rate. Results Twenty-nine articles that measured fixation strength, breach rate, and/or provided SD in relation to pedicle width were selected for inclusion. Conclusions A commonly accepted criteria for pedicle SD selection has not yet been proposed. Screw diameters approximately 80% of the pedicle width have been adopted, but this proportion is rarely reported in the midthoracic vertebrae for which smaller pedicles and inadequate hardware specificity result in higher breach rates. Depending upon the insertion technique adopted, greater specificity in diameter selection by vertebral level should be pursued in order to maximally target cortical bone purchase. Clinical Relevance Based on this review of the literature, we believe that proper selection of the SD for individual vertebral level directly affects the insertion technique and the potential breach.

1 July 2020 in Clinical Biomechanics
Verified
Journal Article
Open access
Patrick A. MasseyPatrick A. Massey
Patrick A. Massey
DPDavid Parker
David Parker
KMKaylan McClary
Kaylan McClary
JRJames Robinson
James Robinson
RBR. Shane Barton
R. Shane Barton
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
Newer repair techniques of anterior cruciate ligament tears, including augmentation with internal brace, have shown promising clinical results. Few biomechanical studies exist comparing anterior cruciate ligament repair only versus repair with internal brace. The purpose of this study was to compare the load to failure and stiffness of anterior cruciate ligament repair with internal brace augmentation versus repair-only. Proximal femoral avulsion type anterior cruciate ligament injuries were created in 20 cadaver knees. Anterior cruciate ligament repair-only or repair with internal brace was performed using arthroscopic tools. Load to failure and failure modes were collected, with calculations of stiffness and energy to failure performed. The average load to failure for the internal brace group was higher than the repair-only group: 693 N (SD 248) versus 279 N (SD 91), P = .002. The stiffness and energy to failure values were higher for the internal brace group than the repair-only group: 83 N/mm versus 58 N/mm, P = .02 and 16.88 J (SD 12.44) versus 6.91 J (SD 2.49), P = .04, respectively. Failure modes differed between groups (P = .00097) with 80% failure in the repair-only due to suture pull through the anterior cruciate ligament and 90% failure in the internal brace group due to suture button pull through the femur. There was higher load to failure, stiffness, and energy to failure for the internal brace group compared to the repair-only group, and a high positive correlation between bone density and load to failure for the internal brace group. Anterior cruciate ligament repair with internal brace augmentation demonstrates significantly higher load to failure. It may be a useful adjunct to protect the anterior cruciate ligament repair from failure during the early stages of healing.

1 December 2014 in Clinical Biomechanics
Verified
Journal Article
Closed access
FAFarid Amirouche
Farid Amirouche
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
SBStefanie Broviak
Stefanie Broviak
MGMark Gonzalez
Mark Gonzalez
WGWayne Goldstein
Wayne Goldstein
RBRiad Barmada
Riad Barmada

23 December 2015 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
NCN. Cappetti
N. Cappetti
Alessandro NaddeoAlessandro Naddeo
Alessandro Naddeo
FNFrancesco Naddeo
Francesco Naddeo
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
The aim of this work is to show a quick and simple procedure able to identify the geometrical parameters of the intervertebral disc that strongly affect the behavior of the FEM model. First, we allocated a selection criterion for the minimum number of geometrical parameters that describe, with a good degree of approximation, a healthy human vertebra. Next, we carried out a sensitivity analysis using the ‘Taguchi orthogonal array’ to arrive at a quick identification of the parameters that strongly affect the behavior of the Fem model.

24 February 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Giovanni F. SolitroGiovanni F. Solitro
Giovanni F. Solitro
FAFarid Amirouche
Farid Amirouche
Pedicle screws are typically used for fusion, percutaneous fixation, and means of gripping a spinal segment. The screws act as a rigid and stable anchor points to bridge and connect with a rod as part of a construct. The foundation of the fusion is directly related to the placement of these screws. Malposition of pedicle screws causes intraoperative complications such as pedicle fractures and dural lesions and is a contributing factor to fusion failure. Computer assisted spine surgery (CASS) and patient-specific drill templates were developed to reduce this failure rate, but the trajectory of the screws remains a decision driven by anatomical landmarks often not easily defined. Current data shows the need of a robust and reliable technique that prevents screw misplacement. Furthermore, there is a need to enhance screw insertion guides to overcome the distortion of anatomical landmarks, which is viewed as a limiting factor by current techniques. The objective of this study is to develop a method and mathematical lemmas that are fundamental to the development of computer algorithms for pedicle screw placement. Using the proposed methodology, we show how we can generate automated optimal safe screw insertion trajectories based on the identification of a set of intrinsic parameters. The results, obtained from the validation of the proposed method on two full thoracic segments, are similar to previous morphological studies. The simplicity of the method, being pedicle arch based, is applicable to vertebrae where landmarks are either not well defined, altered or distorted.