Semih Isik

Mr. Semih Isik

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SISemih Isik
Semih Isik
MAMohammed Alharbi
Mohammed Alharbi
SBSubhashish Bhattacharya
Subhashish Bhattacharya
MMC is an excellent topology for medium-and high-voltage applications due to its advantages over other multi-level converters. However, the control algorithm design needs meticulous attention as each SM capacitor voltage is balanced around their reference. Any voltage inequality between the SM voltage causes the second harmonic-dominated circulating current inside the MMC. The circulating current increases the RMS value of the arm currents, component ratings, and the ripple in the capacitor voltages unless it is appropriately controlled. This paper proposes an optimized closed-loop circulating current control method based on PR and PI controllers in abc reference frame to prevent high circulating current inside an MMC. The proposed method suppresses the magnitude of circulating current while reducing the ripple in capacitor voltages. The ripple in the DC link voltage is also reduced without any supplementary controller under balanced and unbalanced AC grid conditions. Thus, the proposed circulating current control method reduces the conduction losses and component ratings while the converter's efficiency and reliability increase. The method's verification is tested on a point-to-point connected MMC-based HVDC system in a real-time simulator with Xilinx FPGA-based MMC emulator and arm controller.

24 February 2021 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
MAMohammed Alharbi
Mohammed Alharbi
SISemih Isik
Semih Isik
SBSubhashish Bhattacharya
Subhashish Bhattacharya
A submodule (SM) level fault-tolerant method for modular multilevel converters (MMCs) with a scalable control design for medium and high voltage applications is proposed in this paper. A large number of SMs, which is typically required in high-power applications, is divided into sets with a smaller number of SMs. A local controller is assigned to each set for the capacitor voltage balancing (CVB) and switching signal generations, and the SM level protection. A CVB control method is proposed to maintain SM voltages among sets within a pre-specified band under SM failures, in which an MMC arm can operate with unequal numbers of SMs among sets. The computational and communication burdens are reduced in each local controller. Most importantly, changing the number of SMs is achieved without significant modifications in the control system, which improves the expandability and flexibility of the MMC system to easily scale-up to higher voltage levels. A 320 kV/1000 MW MMC system has been studied in a real-time digital simulator (RTDS) and FPGA boards to validate the proposed fault-tolerant control method under SM failures.

1 September 2019
Verified
Conference Paper
Closed access
MAMohammed Alharbi
Mohammed Alharbi
SISemih Isik
Semih Isik
SBSubhashish Bhattacharya
Subhashish Bhattacharya
The circulating current is a negative sequence current at double the fundamental frequency in a Modular Multilevel Converter (MMC). Conventionally, many types of research are conducted to suppress the circulating current in an MMC to reduce the converter loading. However, this paper studies rather than suppressing the circulating current, decoupling control algorithm between circulating current and AC, DC sides of the converter improves the average and RMS current such that performance of the converter increases while rating of the devices minimize. The Sub-Module (SM) capacitor voltage ripple significantly reduces so that the cost of a large scale MMC application decrease. The proposed control algorithm uses AC power as a circulating current reference, so the amplitude and phase of the output currents need not to be calculated. The studies are performed in Real Time Digital Simulator (RTDS) with FPGA based MMC support unit.

1 June 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JSJahangeer Badar Soomro
Jahangeer Badar Soomro
DKDileep Kumar
Dileep Kumar
FAFaheem Akhtar
Faheem Akhtar
SISemih Isik
Semih Isik
MAMohammed Alharbi
Mohammed Alharbi
This study presents an improved, communication-free Fault Ride-Through (FRT) strategy for type-3 and type-4 wind turbine integrated modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems in offshore wind power plants (OWPPs). The research aims to enhance the reliability and resilience of OWPPs by ensuring their connection with AC grids remains intact during and after faults. Simulation results conducted on a 580 kV, 850 MW MMC-HVDC system using PSCAD/EMTDC software v.4.6.2 demonstrate quick post-fault recovery operation and the ability to effectively manage DC link and capacitor voltages within safe limits. Furthermore, the circulating current (CC) and capacitor voltage ripple (CVR) remain within acceptable limits, ensuring safe and reliable operation. The study’s major conclusion is that the proposed FRT strategy effectively mitigates the adverse effects of short circuit faults, such as a rapid rise in DC-link voltage, on the performance of the MMC-HVDC system. By promptly suppressing DC-link overvoltage, the proposed FRT scheme prevents compromising the safe operation of various power electronics equipment. These findings highlight the significance of FRT capability in OWPPs and emphasize the practical applicability of the proposed strategy in enhancing the reliability of offshore wind power generation.

4 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
RARao Atif
Rao Atif
MHMANNAN HASSAN
MANNAN HASSAN
MSMuhammad Bilal Shahid
Muhammad Bilal Shahid
Hafiz Mudassir MunirHafiz Mudassir Munir
Hafiz Mudassir Munir
MSMahmoud S. R. Saeed
Mahmoud S. R. Saeed
MAMohammed Alharbi
Mohammed Alharbi
Model predictive control (MPC) is an efficient and growing approach to power converter control. This paper proposes an improved and simplified model predictive current control (MPCC) technique for a four-level nested neutral point clamped (4L-NNPC) converter. Conventional MPCC exhibits better performances as compared to the conventional linear control system such as fast dynamic response, consideration of the system constraints, and nonlinearities. However, the application of the conventional model predictive current control (MPCC) approach on complex systems provokes a significant number of calculations, which is the main hurdle to its practical implementation. To fix this flaw, this paper proposes an effective algorithm to shorten the execution time of the conventional MPCC. In this proposed technique, 216 current predictions of the conventional MPCC are skipped and converted into one required voltage vector (RVV) prediction. With this equivalent reference voltage transformation, the calculation burden of MPCC is significantly reduced, while the output performance is not influenced. The results of the simplified MPCC for the 4L-NNPC converter are analyzed and compared with the conventional MPCC. The computational time is reduced by 19.56% using the simplified MPCC, while keeping an approximately similar error of output currents. The switching frequency and total harmonic distortion (THD) of the proposed method are reduced by 8.16% and 0.07%, respectively, as compared to the conventional technique. These results demonstrate the fact that that the performance of a conventional MPCC is enhanced with the proposed MPCC. The proposed algorithm can be applied to several inverter topologies.

12 July 2022 in IEEE Access
Verified
Journal Article
Open access
SISemih Isik
Semih Isik
SPSanket Parashar
Sanket Parashar
SBSubhashish Bhattacharya
Subhashish Bhattacharya
Power Conditioning Systems (PCS) based on three-level converters with series-connected 10kV SiC MOSFETs have gained popularity for medium voltage applications with the increase in distributed energy sources. With the use of Silicon Carbide (SiC), a wide bandgap semiconductor composed of Silicon (Si) and Carbon (C), MOSFET increases in power electronics application due to higher switching frequency operations. A high switching frequency such as 10 kHz or more leads to a reduction in magnetic components’ size and the PCS structure’s size. Therefore, the smaller, modular, and lightweight PCS can be attained for micro-grid integration, EV charging, or high inertia-dominated power grid applications. The three-level NPC (3L-NPC) inverter using series-connected 10kV SiC MOSFET is a suitable topology for coupling the PCS with the medium-voltage utility grid. The converter’s pole sustainability increases with the two series-connected switches, yet the switches are still sensitive and prone to malfunction under various environmental and mechanical causes. Therefore, a meticulous fault isolation and coordination design may be necessary for the front-end converter for possible switch faults in the converter poles. A well-designed fault-tolerant controller may sustain the converter operation under fault conditions while protecting the healthy parts of the converter. Besides, it minimizes the harmful effects of fault on the grid side and increases the system availability. This paper analyzes short and open circuit switch faults that might occur in the PCS. Accordingly, a fault-tolerant method and a fault isolation method are proposed. The proposed methods are verified with Saber™ and the Real-Time Digital Simulator simulation platforms.