Mohammed Alharbi

Dr. Mohammed Alharbi

King Saud University, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
JMJian Mei
Jian Mei
XMXuan Meng
Xuan Meng
XTXingwang Tang
Xingwang Tang
HLHeran Li
Heran Li
Hany M. HasanienHany M. Hasanien
Hany M. Hasanien
Kai SongKai Song
Kai Song
Accurate and reliable mathematical modeling is essential for the optimal control and performance analysis of polymer electrolyte membrane fuel cell (PEMFC) systems, which are mainly implemented based on accurate parameter estimation. In this paper, a multi-strategy tuna swarm optimization (MS-TSO) is proposed to estimate the parameters of PEMFC voltage models and compare them with other optimizers such as differential evolution, the whale optimization approach, the salp swarm algorithm, particle swarm optimization, Harris hawk optimization and the slime mould algorithm. In the optimizing routine, the unidentified factors of the PEMFCs are used as the decision variables, which are optimized to minimize the sum of square errors between the estimated and measured data. The optimizers are examined based on three PEMFC datasets including BCS500W, NedStackPS6 and harizon500W as well as a set of experimental data which are measured using the Greenlight G20 platform with a 25 cm2 single cell at 353 K. It is confirmed that MS-TSO gives better performance in terms of convergence speed and accuracy than the competing algorithms. Furthermore, the results achieved by MS-TSO are compared with other reported approaches in the literature. The advantages of MS-TSO in ascertaining the optimum factors of various PEMFCs have been comprehensively demonstrated.

28 June 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SISemih Isik
Semih Isik
MAMohammed Alharbi
Mohammed Alharbi
SBSubhashish Bhattacharya
Subhashish Bhattacharya
MMC is an excellent topology for medium-and high-voltage applications due to its advantages over other multi-level converters. However, the control algorithm design needs meticulous attention as each SM capacitor voltage is balanced around their reference. Any voltage inequality between the SM voltage causes the second harmonic-dominated circulating current inside the MMC. The circulating current increases the RMS value of the arm currents, component ratings, and the ripple in the capacitor voltages unless it is appropriately controlled. This paper proposes an optimized closed-loop circulating current control method based on PR and PI controllers in abc reference frame to prevent high circulating current inside an MMC. The proposed method suppresses the magnitude of circulating current while reducing the ripple in capacitor voltages. The ripple in the DC link voltage is also reduced without any supplementary controller under balanced and unbalanced AC grid conditions. Thus, the proposed circulating current control method reduces the conduction losses and component ratings while the converter's efficiency and reliability increase. The method's verification is tested on a point-to-point connected MMC-based HVDC system in a real-time simulator with Xilinx FPGA-based MMC emulator and arm controller.

1 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
MHMohamed Sayed Hashish
Mohamed Sayed Hashish
Hany M. HasanienHany M. Hasanien
Hany M. Hasanien
HAORAN JIHAORAN JI
HAORAN JI
AAAbdulaziz Alkuhayli
Abdulaziz Alkuhayli
MAMohammed Alharbi
Mohammed Alharbi
ABAhmed Badr
Ahmed Badr
This paper proposes a new, metaheuristic optimization technique, Artificial Gorilla Troops Optimization (GTO), for a hybrid power system with photovoltaic (PV) and wind energy (WE) sources, solving the probabilistic optimum power flow (POPF) issue. First, the selected algorithm is developed and evaluated such that it applies to solve the classical optimum power flow (OPF) approach with the total fuel cost as the objective function. Second, the proposed algorithm is used for solving the POPF, including the PV and WE sources, considering the uncertainty of these renewable energy sources (RESs). The performance of the suggested algorithm was confirmed using the standard test systems IEEE 30-bus and 118-bus. Different scenarios involving different sets of the PV and WE sources and fixed and variable loads were considered in this study. The comparison of the obtained results from the suggested algorithm with other algorithms mentioned in this literature has confirmed the efficiency and performance of the proposed algorithm for providing optimal solutions for a hybrid power system. Furthermore, the results showed that the penetration of the PV and WE sources in the system significantly reduces the total cost of the system.

23 May 2024 in IEEE Access
Verified
Journal Article
Open access
AAAyedh Alqahtani
Ayedh Alqahtani
Hany M. HasanienHany M. Hasanien
Hany M. Hasanien
MAMohammed Alharbi
Mohammed Alharbi
SCSun Chuanyu
Sun Chuanyu
Proton Exchange Membrane Fuel Cells (PEMFCs) play a crucial role in the advancement of clean hydrogen vehicles. Their ability to convert hydrogen into electricity makes them promising candidates to replace conventional engines. However, optimizing their performance and efficiency necessitates accurate modeling techniques capable of simulating their behavior. In this context, this paper proposes an advanced approach for precise parameter estimation in PEMFC models. Employing an Enhanced Walrus Optimization (EWO) algorithm integrated with Lévy flight exploration, the approach tackles the inherent nonlinearity of PEMFC systems. The technique aims to minimize the squared error between measured and simulated terminal voltage, thereby ensuring superior accuracy and robustness compared to established algorithms. The effectiveness of the proposed model is validated through comparisons between theoretical simulations and experimental measurements. The findings demonstrate the efficacy of the EWO algorithm, consistently outperforming previously published algorithms and achieving notably lower errors. Moreover, the incorporation of Lévy flights enhances the algorithm’s capabilities, leading to expedited convergence and more accurate parameter estimations. Beyond facilitating precise parameter estimation, this enhanced modeling strategy opens avenues for refining design and optimization strategies in fuel cell research and development. The major contributions of this paper include the enhancement of the WO algorithm, evaluation of theoretical model accuracy, and robustness assessment of the EWO in optimizing the PEMFC model. By furnishing accurate models validated through experimental evidence, this enhanced modeling strategy paves the way for refining design and optimization strategies in fuel cell research and development.

13 March 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
MAMohammed Alharbi
Mohammed Alharbi
Muhammad RagabMuhammad Ragab
Muhammad Ragab
Kareem AboRasKareem AboRas
Kareem AboRas
Hossam KotbHossam Kotb
Hossam Kotb
MDMasoud Dashtdar
Masoud Dashtdar
EEElmazeg Elgamli
Elmazeg Elgamli
In this article, the problem of voltage and frequency stability in a hybrid multi-area power system including renewable energy sources (RES) and electric vehicles has been investigated. Fractional order systems have been used to design innovative controllers for both load frequency control (LFC) and automatic voltage regulator (AVR) based on the combination of fractional order proportional-integral and proportional-integral-derivative plus double derivative (FOPI–PIDD2). Here, the dandelion optimizer (DO) algorithm is used to optimize the proposed FOPI–PIDD2 controller to stabilize the voltage and frequency of the system. Finally, the results of simulations performed on MATLAB/Simulink show fast, stable, and robust performance based on sensitivity analysis, as well as the superiority of the proposed optimal control strategy in damping frequency fluctuations and active power, exchanged between areas when faced with step changes in load, the changes in the generation rate of units, and the uncertainties caused by the wide changes of dynamic values.

25 September 2023 in International Journal of Energy Research
Verified
Journal Article
Open access
PDF file
AWAbdul Wajid
Abdul Wajid
ARAtiq Ur Rehman
Atiq Ur Rehman
SISheeraz Iqbal
Sheeraz Iqbal
MPMukesh Pushkarna
Mukesh Pushkarna
SHSyed Mudassir Hussain
Syed Mudassir Hussain
Ievgen ZaitsevIevgen Zaitsev
Ievgen Zaitsev
The power transformer is an essential component of the electrical network that can be used to step up and step down voltage. Dissolved gas analysis (DGA) is the most reliable method for the identification of incipient faults in power transformers. Various DGA methods are used to observe the generated key gases after oil decomposition. The main gases included are hydrogen (H2), ethylene (C2H4), acetylene (C2H2), methane (CH4), and ethane (C2H6). There is a lack of research that can compare the performance of various DGA methods in identification of faults in power transformer. In addition, it is also not clear which DGA method is optimal for identification of faults in power transformer. In this paper, the comparative performance study of seven DGA methods such as Rogers ratio, key gas, IEC ratio, the Doernenburg ratio, the Duval triangle, three-ratio method, and the relative percentage of four gases is carried out in order to identify the optimal technique for fault identification in transformer. The data of various power transformers installed in RAWAT NTDC grid station, Islamabad, and UCH-II power station, Balochistan, are considered for the comparative analysis. This analysis shows that the three-ratio method provides better performance than other DGA methods in accurately identifying the faults in power transformers. The three-ratio method has 90 accuracy in identifying the faults in power transformer.