Cristina Tortolini

Dr. Cristina Tortolini

Department of Experimental Medicine, 'Sapienza', University of Rome, Rome, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
Cristina TortoliniCristina Tortolini
Cristina Tortolini
Paolo BollellaPaolo Bollella
Paolo Bollella
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
Gabriele FaveroGabriele Favero
Gabriele Favero
Franco MazzeiFranco Mazzei
Franco Mazzei
RARiccarda Antiochia
Riccarda Antiochia
A single-use electrochemical screen-printed electrode is reported based on biomimetic properties of nanoceria particles (CeNPs). The developed tool showed an easy approach compared to the classical spectrophotometric methods reported in literature in terms of ease of use, cost, portability, and unnecessary secondary reagents. The sensor allowed the detection of the total antioxidant capacity (TAC) in wine samples. The sensor has been optimized and characterized electrochemically and then tested with antioxidant compounds occurred in wine samples. The electrochemical CeNPs modified sensor has been used for detection of TAC in white and red commercial wines and the data compared to the 2,2′-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid (ABTS)-based spectrophotometric method. Finally, the obtained results have demonstrated that the proposed sensor was suitable for the simple and quick evaluation of TAC in beverage samples.

12 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
VGValeria Gigli
Valeria Gigli
Cristina TortoliniCristina Tortolini
Cristina Tortolini
Eliana CapecchiEliana Capecchi
Eliana Capecchi
AAAntonio Angeloni
Antonio Angeloni
ALAndrea Lenzi
Andrea Lenzi
RARiccarda Antiochia
Riccarda Antiochia
The regulation of nervous and cardiovascular systems and some brain-related behaviors, such as stress, panic, anxiety, and depression, are strictly dependent on the levels of the main catecholamines of clinical interest, dopamine (DA), epinephrine (EP), and norepinephrine (NEP). Therefore, there is an urgent need for a reliable sensing device able to accurately monitor them in biological fluids for early diagnosis of the diseases related to their abnormal levels. In this paper, we present the first tyrosinase (Tyr)-based biosensor based on chitosan nanoparticles (ChitNPs) for total catecholamine (CA) detection in human urine samples. ChitNPs were synthetized according to an ionic gelation process and successively characterized by SEM and EDX techniques. The screen-printed graphene electrode was prepared by a two-step drop-casting method of: (i) ChitNPS; and (ii) Tyr enzyme. Optimization of the electrochemical platform was performed in terms of the loading method of Tyr on ChitNPs (nanoprecipitation and layer-by-layer), enzyme concentration, and enzyme immobilization with and without 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as cross-linking agents. The Tyr/EDC-NHS/ChitNPs nanocomposite showed good conductivity and biocompatibility with Tyr enzyme, as evidenced by its high biocatalytic activity toward the oxidation of DA, EP, and NEP to the relative o-quinone derivatives electrochemically reduced at the modified electrode. The resulting Tyr/EDC-NHS/ChitNPs-based biosensor performs interference-free total catecholamine detection, expressed as a DA concentration, with a very low LOD of 0.17 μM, an excellent sensitivity of 0.583 μA μM−1 cm−2, good stability, and a fast response time (3 s). The performance of the biosensor was successively assessed in human urine samples, showing satisfactory results and, thus, demonstrating the feasibility of the proposed biosensor for analyzing total CA in physiological samples.

1 September 2018 in Microchemical Journal
Verified
Journal Article
Closed access
DZDaniele Zappi
Daniele Zappi
GMgiancarlo masci
giancarlo masci
CSClaudia Sadun
Claudia Sadun
Cristina TortoliniCristina Tortolini
Cristina Tortolini
MAMarta Letizia Antonelli
Marta Letizia Antonelli
Paolo BollellaPaolo Bollella
Paolo Bollella

12 March 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Cristina TortoliniCristina Tortolini
Cristina Tortolini
Eliana CapecchiEliana Capecchi
Eliana Capecchi
Federico TascaFederico Tasca
Federico Tasca
RPRiccardo Pofi
Riccardo Pofi
MARY ANNA VENNERIMARY ANNA VENNERI
MARY ANNA VENNERI
RARiccarda Antiochia
Riccarda Antiochia
Novel nanoarchitectures based on lignin nanoparticles (LNPs) were designed and realized for electrochemical eco-friendly biosensing development. Two types of lignin nanoparticles were utilized for the modification of a gold bare electrode, namely organosolv (OLNPs) and kraft lignin (KLNPs) nanoparticles, synthetized from a sulfur-free and a sulfur lignin, respectively. The electrochemical behavior of LNP-modified electrodes was studied using two electrochemical techniques, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Compared to the gold bare electrode, an evident decrease in the faradaic current and increase of the ΔEp were observed in cyclic voltammograms. In addition, larger semicircles were registered in Nyquist plots. These results suggest a strong inhibition effect of the electron transfer reaction by LNPs layer, especially in the case of KLNPs. The modified electrodes, properly assembled with concanavalin A (ConA) and glucose oxidase (GOx), were successively tested as biosensing platforms for glucose, showing a sensitivity of (4.53 ± 0.467) and (13.74 ± 1.84) μA mM−1 cm2 for Au/SAMCys/OLNPs/ConA/GOx and Au/KLNPs/ConA/GOx biosensors, respectively. Finally, different layers of the KNLPs/ConA/GOx-modified Au electrode were tested, and the three-layered Au(KNLPs/ConA/GOx)3 showed the best analytical performance.

18 December 2016 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
GFGiovanni Fusco
Giovanni Fusco
Paolo BollellaPaolo Bollella
Paolo Bollella
Franco MazzeiFranco Mazzei
Franco Mazzei
Gabriele FaveroGabriele Favero
Gabriele Favero
RARiccarda Antiochia
Riccarda Antiochia
Cristina TortoliniCristina Tortolini
Cristina Tortolini
A catalase-based (NAF/MWCNTs) nanocomposite film modified glassy carbon electrode for hydrogen peroxide (H2O2) detection was developed. The developed biosensor was characterized in terms of its bioelectrochemical properties. Cyclic voltammetry (CV) technique was employed to study the redox features of the enzyme in the absence and in the presence of nanomaterials dispersed in Nafion® polymeric solution. The electron transfer coefficient,α, and the electron transfer rate constant,ks, were found to be 0.42 and 1.71 s−1, at pH 7.0, respectively. Subsequently, the same modification steps were applied to mesoporous graphite screen-printed electrodes. Also, these electrodes were characterized in terms of their main electrochemical and kinetic parameters. The biosensor performances improved considerably after modification with nanomaterials. Moreover, the association of Nafion with carbon nanotubes retained the biological activity of the redox protein. The enzyme electrode response was linear in the range 2.5–1150 μmol L−1, with LOD of 0.83 μmol L−1. From the experimental data, we can assess the possibility of using the modified biosensor as a useful tool for H2O2determination in packaged beverages.

16 August 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Cristina TortoliniCristina Tortolini
Cristina Tortolini
Federico TascaFederico Tasca
Federico Tasca
MARY ANNA VENNERIMARY ANNA VENNERI
MARY ANNA VENNERI
Cinzia MarcheseCinzia Marchese
Cinzia Marchese
RARiccarda Antiochia
Riccarda Antiochia
Herein, the effects of nanostructured modifications of a gold electrode surface in the development of electrochemical sensors for L-ascorbic acid detection have been investigated. In particular, a bare gold electrode has been modified by electrodeposition of gold single-walled carbon nanotubes (Au/SWCNTs) and by the formation of a highly nanoporous gold (h-nPG) film. The procedure has been realized by sweeping the potential between +0.8 V and 0 V vs. Ag/AgCl for 25 scans in a suspension containing 5 mg/mL of SWCNTs in 10 mM HAuCl4 and 2.5 M NH4Cl solution for Au/SWCNTs modified gold electrode. A similar procedure was applied for a h-nPG electrode in a 10 mM HAuCl4 solution containing 2.5 M NH4Cl, followed by applying a fixed potential of −4 V vs. Ag/AgCl for 60 s. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the properties of the modified electrodes. The developed sensors showed strong electrocatalytic activity towards ascorbic acid oxidation with enhanced sensitivities of 1.7 × 10−2 μA μM−1cm−2 and 2.5 × 10−2 μA μM−1cm−2 for Au/SWCNTs and h-nPG modified electrode, respectively, compared to bare gold electrode (1.0 × 10−2 μA μM−1cm−2). The detection limits were estimated to be 3.1 and 1.8 μM, respectively. The h-nPG electrode was successfully used to determine ascorbic acid in human urine with no significant interference and with satisfactory recovery levels.