DC power systems are gaining an increasing interest in renewable energy applications because of the good matching with dc output type sources such as photovoltaic (PV) systems and secondary batteries. In this paper, several distributed generators (DGs) have been merged together with a pair of batteries and loads to form an autonomous dc microgrid (MG). To overcome the control challenge associated with coordination of multiple batteries within one stand-alone MG, a double-layer hierarchical control strategy was proposed. 1) The unit-level primary control layer was established by an adaptive voltage-droop method aimed to regulate the common bus voltage and to sustain the states of charge (SOCs) of batteries close to each other during moderate replenishment. The control of every unit was expanded with unit-specific algorithm, i.e., finish-of-charging for batteries and maximum power-point tracking (MPPT) for renewable energy sources, with which a smooth online overlap was designed and 2) the supervisory control layer was designed to use the low-bandwidth communication interface between the central controller and sources in order to collect data needed for adaptive calculation of virtual resistances (VRs) as well as transit criteria for changing unit-level operating modes. A small-signal stability for the whole range of VRs. The performance of developed control was assessed through experimental results.
Current trends indicate that worldwide electricity distribution networks are experiencing a transformation toward direct current (dc) at both the generation and consumption level. This tendency is powered by the outburst of various electronic loads and, at the same time, the struggle to meet the lofty goals for the sharing of renewable energy sources (RESs) in satisfying total demand. RESs operate either natively at dc or have a dc link in the heart of their power electronic interface, whereas the end-point connection of electronic loads, batteries, and fuel cells is exclusively dc. Therefore, merging these devices into dedicated dc distribution architectures through corresponding dc?dc converters is an attractive option not only in terms of enhancing efficiency because of reduction of conversion steps but also for realizing power quality independence from the utility mains. These kinds of systems generally provide improved reliability in comparison to their alternating current (ac) counterparts since the number of active elements in dc?dc power electronic devices is smaller than in dc-ac converters. Control design in dc systems is also significantly simpler since there are no reactive and harmonic power flows or problems with synchronization.
1 February 2016 in IET Generation, Transmission & Distribution
Changes in the electricity business environment, dictated mostly by the increasing integration of renewable energy sources characterised by variable and uncertain generation, create new challenges especially in the liberalised market environment. The role of energy storage systems (ESS) is recognised as a mean to provide additional system security, reliability and flexibility to respond to changes that are still difficult to accurately forecast. However, there are still open questions about benefits these units bring to the generation side, system operators and the consumers. This study provides a comprehensive overview of the current research on ESS allocation (ESS sizing and siting), giving a unique insight into issues and challenges of integrating ESS into distribution networks and thus giving framework guidelines for future ESS research.
6 May 2014 in IEEE Transactions on Sustainable Energy
This paper describes a robust optimization approach to minimize the total cost of supplying a remote telecommunication station exclusively by renewable energy sources (RES). Due to the intermittent nature of RES, such as photovoltaic (PV) panels and small wind turbines, they are normally supported by a central energy storage system (ESS), consisting of a battery and a fuel cell. The optimization is carried out as a robust mixed-integer linear program (RMILP), and results in different optimal solutions, depending on budgets of uncertainty, each of which yields different RES and storage capacities. These solutions are then tested against a set of possible outcomes, thus simulating the future operation of the system. Since battery cycling is inevitable in this application, an algorithm that counts the number of cycles and associated depths of discharges (DoD) is applied to the optimization results. The annual capacity reduction that results from these cycles is calculated for two types of battery technologies, i.e., valve-regulated lead-acid (VRLA) and lithium-ion (Li-ion), and treated as an additional cost. Finally, all associated costs are added up and the ideal configuration is proposed.
1 December 2013 in International Journal of Electrical Power & Energy Systems