In this paper, a wideband antenna is proposed for ultra-wideband microwave imaging applications. The antenna is comprised of a tapered slot ground, a rectangular slotted patch and four star-shaped parasitic components. The added slotted patch is shown to be effective in improving the bandwidth and gain. The proposed antenna system provides a realized gain of 6 dBi, an efficiency of around 80% on the radiation bandwidth, and a wide impedance bandwidth (S11 < −10 dB) of 6.3 GHz (from 3.8 to 10.1 GHz). This supports a true wideband operation. Furthermore, the fidelity factor for face-to-face (FtF) direction is 91.6%, and for side by side (SbS) is 91.2%. This proves the excellent directionality and less signal distortion of the designed antenna. These high figures establish the potential use of the proposed antenna for imaging. A heterogeneous breast phantom with dielectric characteristics identical to actual breast tissue with the presence of tumors was constructed for experimental validation. An antenna array of the proposed antenna element was situated over an artificial breast to collect reflected and transmitted waves for tumor characterization. Finally, an imaging algorithm was used to process the retrieved data to recreate the image in order to detect the undesirable tumor object inside the breast phantom.
In this research work, a symmetrical four-capacitance loaded complementary circular split ring resonator is proposed, which uses an ultra-thin Zinc Selenide (ZnSe) substrate to realize a low-profile triple-band metamaterial (MTM) perfect absorber for application in the terahertz (THz) frequency range. The electromagnetic properties of the proposed structure were calculated and investigated using the Finite Integration Technique (FIT). The proposed structure exhibited three highly absorptive (nearly perfect) peaks at the resonance frequencies of 15.68 THz, 37.48 THz, and 39.55 THz. Furthermore, the absorber was found to be insensitive to the polarization and incident wave angles, due to its symmetrical design. The effects of the conductor type, substrate thickness, unit cell dimension, resonator gap, and substrate type on the reflection and absorption spectra were investigated. To validate the numerical results, the proposed design was analyzed using High-Frequency Simulation Software (HFSS) and Advanced Design System (ADS). The surface current, electric field, and magnetic field distributions at the three-resonance frequency were analyzed. It was concluded that the overall performance of the proposed MTM structure was superior compared to those reported in the literature. The proposed design could be a good candidate for application in stealth technology, imaging, and thermal energy harvesting.
In this study, various breast phantom (BP) models for microwave breast imaging (MBI) are investigated and the creation and assessment of designed models are presented. Symmetrical and asymmetrical BP models have been constructed. based on 3D printed structures stuffed with various mixed material combinations that roles various breast tissue layers (skin, healthy fat tissue, glandular tissue, heterogeneous mix tissue, and tumor tissue) in terms of permittivity over the ultra-wide band frequency (3.1–10.6GHz) range. However, the main issue in making such phantoms is coming up with adequate material mixes that mimic those characteristics across the frequency band, as well as creating the phantom with realistic approach. The complex dielectric characteristics are tested after fabrication with a dielectric probe kit coupled to a VNA. Then, the measured complex dielectric properties are compared to the real human breast dielectric values. The symmetrical and asymmetrical phantoms’ integrated structure allows the tumor and BPs to be dynamically combined to provide a test setup based on MBI technologies. Once the breast phantom has been produced, antenna arrays are positioned around it to collect scattering parameter data for tumor characterization. Finally, the extracted feature data was used to reconstruct the image in order to find the undesirable tumor component within the breast phantom using an imaging algorithm.
In recent years, Ultrawideband (UWB) microwave detection technology has been widely utilized by various researchers to develop biosensors for breast cancer diagnosis. This work emphasizes on design, analysis, and integration of an improved antenna biosensor into an in-house developed breast cancer detection system. The proposed biosensor comprises of a slotted rectangular microstrip patch antenna that is topped with a metamaterial surface to form a compact size of 20×20×10 mm 3 . The slotted patch is considered to improve the -10 dB impedance bandwidth (-10 BW) while incorporating a metamaterial surface, which comprises of a 2×2 dual-circular ring element array, is utilized to enhance the biosensor focusing power achieving a maximum gain of 5.6 dBi with a wide -10 BW of 9.5 GHz (3.5 GHz-13 GHz). The time domain analysis of the antenna biosensor exhibited a minimal group delay of less than 1ns and fidelity factors of 70.94% for side-by-side (SbS) and 85.01% for face-to-face (FtF) arrangements. These results underscore the biosensor’s resistance to distortion and its suitability for real-time Microwave Imaging (MWI) in biomedical applications. Full-wave simulations as well as measured results obtained using a complete breast cancer detection system set up, which comprises two antenna biosensors (Tx Antenna and Rx Antenna), a fabricated breast phantoms with different tumor sizes and distribution, and an automated electromechanical imaging system, was successfully used to perform MWI of breast cancer tumors of different sizes and locations.