Mohamed Taouzari

Prof. Dr. Mohamed Taouzari

Université Hassan 1er, Settat, Casablanca-Settat, Morocco
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
FZFatima-ezzahra zerrad
Fatima-ezzahra zerrad
MTMohamed Taouzari
Mohamed Taouzari
EMEL MOSTAFA MAKROUM
EL MOSTAFA MAKROUM
JAJamal El Aoufi
Jamal El Aoufi
SQSalah Qanadli
Salah Qanadli
ZAHRILADHA ZAKARIAZAHRILADHA ZAKARIA
ZAHRILADHA ZAKARIA
In this paper, a wideband antenna is proposed for ultra-wideband microwave imaging applications. The antenna is comprised of a tapered slot ground, a rectangular slotted patch and four star-shaped parasitic components. The added slotted patch is shown to be effective in improving the bandwidth and gain. The proposed antenna system provides a realized gain of 6 dBi, an efficiency of around 80% on the radiation bandwidth, and a wide impedance bandwidth (S11 < −10 dB) of 6.3 GHz (from 3.8 to 10.1 GHz). This supports a true wideband operation. Furthermore, the fidelity factor for face-to-face (FtF) direction is 91.6%, and for side by side (SbS) is 91.2%. This proves the excellent directionality and less signal distortion of the designed antenna. These high figures establish the potential use of the proposed antenna for imaging. A heterogeneous breast phantom with dielectric characteristics identical to actual breast tissue with the presence of tumors was constructed for experimental validation. An antenna array of the proposed antenna element was situated over an artificial breast to collect reflected and transmitted waves for tumor characterization. Finally, an imaging algorithm was used to process the retrieved data to recreate the image in order to detect the undesirable tumor object inside the breast phantom.

19 July 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
Yadgar I. AbdulkarimYadgar I. Abdulkarim
Yadgar I. Abdulkarim
FAFatih Alkurt
Fatih Alkurt
HNHalgurd Nawzad
Halgurd Nawzad
OAOLCAY ALTINTAS
OLCAY ALTINTAS
Fahmi F. MuhammadsharifFahmi F. Muhammadsharif
Fahmi F. Muhammadsharif
Jian DongJian Dong
Jian Dong
In this research work, a symmetrical four-capacitance loaded complementary circular split ring resonator is proposed, which uses an ultra-thin Zinc Selenide (ZnSe) substrate to realize a low-profile triple-band metamaterial (MTM) perfect absorber for application in the terahertz (THz) frequency range. The electromagnetic properties of the proposed structure were calculated and investigated using the Finite Integration Technique (FIT). The proposed structure exhibited three highly absorptive (nearly perfect) peaks at the resonance frequencies of 15.68 THz, 37.48 THz, and 39.55 THz. Furthermore, the absorber was found to be insensitive to the polarization and incident wave angles, due to its symmetrical design. The effects of the conductor type, substrate thickness, unit cell dimension, resonator gap, and substrate type on the reflection and absorption spectra were investigated. To validate the numerical results, the proposed design was analyzed using High-Frequency Simulation Software (HFSS) and Advanced Design System (ADS). The surface current, electric field, and magnetic field distributions at the three-resonance frequency were analyzed. It was concluded that the overall performance of the proposed MTM structure was superior compared to those reported in the literature. The proposed design could be a good candidate for application in stealth technology, imaging, and thermal energy harvesting.

8 September 2022 in IEEE Access
Verified
Journal Article
Open access
FZFatima-ezzahra zerrad
Fatima-ezzahra zerrad
MTMohamed Taouzari
Mohamed Taouzari
EMEl Mostafa Makroum
El Mostafa Makroum
Sarosh AhmadSarosh Ahmad
Sarosh Ahmad
FAFatih O. Alkurt
Fatih O. Alkurt
Mousa I HusseinMousa I Hussein
Mousa I Hussein
In this study, various breast phantom (BP) models for microwave breast imaging (MBI) are investigated and the creation and assessment of designed models are presented. Symmetrical and asymmetrical BP models have been constructed. based on 3D printed structures stuffed with various mixed material combinations that roles various breast tissue layers (skin, healthy fat tissue, glandular tissue, heterogeneous mix tissue, and tumor tissue) in terms of permittivity over the ultra-wide band frequency (3.1–10.6GHz) range. However, the main issue in making such phantoms is coming up with adequate material mixes that mimic those characteristics across the frequency band, as well as creating the phantom with realistic approach. The complex dielectric characteristics are tested after fabrication with a dielectric probe kit coupled to a VNA. Then, the measured complex dielectric properties are compared to the real human breast dielectric values. The symmetrical and asymmetrical phantoms’ integrated structure allows the tumor and BPs to be dynamically combined to provide a test setup based on MBI technologies. Once the breast phantom has been produced, antenna arrays are positioned around it to collect scattering parameter data for tumor characterization. Finally, the extracted feature data was used to reconstruct the image in order to find the undesirable tumor component within the breast phantom using an imaging algorithm.

15 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FZFatima-ezzahra zerrad
Fatima-ezzahra zerrad
MTMohamed Taouzari
Mohamed Taouzari
EAEqab Almajali
Eqab Almajali
Muharrem KaraaslanMuharrem Karaaslan
Muharrem Karaaslan
JAJamal El Aoufi
Jamal El Aoufi
AHAbir Jaafar Hussain
Abir Jaafar Hussain
In recent years, Ultrawideband (UWB) microwave detection technology has been widely utilized by various researchers to develop biosensors for breast cancer diagnosis. This work emphasizes on design, analysis, and integration of an improved antenna biosensor into an in-house developed breast cancer detection system. The proposed biosensor comprises of a slotted rectangular microstrip patch antenna that is topped with a metamaterial surface to form a compact size of 20×20×10 mm 3 . The slotted patch is considered to improve the -10 dB impedance bandwidth (-10 BW) while incorporating a metamaterial surface, which comprises of a 2×2 dual-circular ring element array, is utilized to enhance the biosensor focusing power achieving a maximum gain of 5.6 dBi with a wide -10 BW of 9.5 GHz (3.5 GHz-13 GHz). The time domain analysis of the antenna biosensor exhibited a minimal group delay of less than 1ns and fidelity factors of 70.94% for side-by-side (SbS) and 85.01% for face-to-face (FtF) arrangements. These results underscore the biosensor’s resistance to distortion and its suitability for real-time Microwave Imaging (MWI) in biomedical applications. Full-wave simulations as well as measured results obtained using a complete breast cancer detection system set up, which comprises two antenna biosensors (Tx Antenna and Rx Antenna), a fabricated breast phantoms with different tumor sizes and distribution, and an automated electromechanical imaging system, was successfully used to perform MWI of breast cancer tumors of different sizes and locations.