Brian A Mazzeo

Prof. Brian A Mazzeo

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Batteries
Verified
Journal Article
Open access
PDF file
MNMojdeh Nikpour
Mojdeh Nikpour
BLBaichuan Liu
Baichuan Liu
PMPaul Minson
Paul Minson
ZHZachary Hillman
Zachary Hillman
BMBrian A Mazzeo
Brian A Mazzeo
DWDean Wheeler
Dean Wheeler
The drying process of electrodes might seem to be a simple operation, but it has profound effects on the microstructure. Some unexpected changes can happen depending on the drying conditions. In prior work, we developed the multiphase-smoothed-particle (MPSP) model, which predicted a relative increase in the carbon additive and binder adjacent to the current collector during drying. This motivated us to undertake the present experimental investigation of the relationship between the drying rate and microstructure and transport properties for a typical anode and cathode. Specifically, the drying rate was controlled by means of temperature for both an NMC532 cathode and graphite anode. The material distribution was analyzed using a combination of cross-section SEM images and the energy-dispersive X-ray spectroscopy elemental maps. The binder concentration gradients were developed in both the in- and through-plane directions. The through-plane gradient is evident at a temperature higher than 150 °C, whereas the in-plane variations resulted at all drying temperatures. The measurements identified an optimum temperature (80 °C) that results in high electronic conductivity and low ionic resistivity due to a more uniform binder distribution. Trends in transport properties are not significantly altered by calendering, which highlights the importance of the drying rate itself on the assembled cell properties.

5 March 2019 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
WGW. Spencer Guthrie
W. Spencer Guthrie
JLJacob L. Larsen
Jacob L. Larsen
JBJared S. Baxter
Jared S. Baxter
BMBrian A Mazzeo
Brian A Mazzeo

13 July 2020 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
LHLorin J. Hendricks
Lorin J. Hendricks
JBJared S. Baxter
Jared S. Baxter
YCYao Chou
Yao Chou
MTMavrik Thomas
Mavrik Thomas
EBEnoch Boekweg
Enoch Boekweg
BMBrian A Mazzeo
Brian A Mazzeo

1 August 2022 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
JVJohn E. Vogel
John E. Vogel
JSJarom G. Sederholm
Jarom G. Sederholm
ESEdmund M. Shumway
Edmund M. Shumway
GAGabriel J. Abello
Gabriel J. Abello
STStephen Trask
Stephen Trask
BMBrian A Mazzeo
Brian A Mazzeo
Li-ion battery electrode electronic properties, including bulk conductivity and contact resistance, are critical parameters affecting cell performance and fast-charge capability. Contact resistance between the coating and current collector is often the largest electronic resistance in an electrode and is affected by chemical, microstructural, and interfacial variations. Direct measurements of contact resistance and bulk conductivity have proven to be challenging. In their absence, a mechanical electrode peel test is often used to compare adhesion and electrical contact resistance. However, using a micro-flexible-surface probe, contact resistance can be directly determined. This work compares contact resistance and mechanical peel strength of multiple commercial-grade HE5050 and NCM523 cathodes and graphite and silicon anodes. It was found that peel strength correlates well with contact resistance in a carefully curated data set (p < 0.05) and in some situations may be a good metric to estimate electrical properties. However, there were distinct outliers in the data set, indicating that peel strength may not accurately reflect electrical properties when there is significant variation in electrode composition. These results illustrate the value of the micro-flexible-surface probe in quantifying contact resistance and bulk conductivity to better understand how battery composition and processing steps affect microstructure and resulting cell performance.

19 March 2007 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
BMBrian A Mazzeo
Brian A Mazzeo
AFAndrew J. Flewitt
Andrew J. Flewitt
Dielectric spectroscopy was used to measure the dielectric relaxation of bovine serum albumin, Protein A, and rabbit IgG in solution. Measurements were performed with an impedance analyzer and dielectric cell. Protein additions to bulk solution were measured by differential dielectric relaxation spectroscopy, presented as a method to measure the individual contributions of proteins to relaxation phenomena and reduce effects of electrode polarization. Relaxation characteristics of the proteins individually and as a complex were observed. Frequency shifts in the relaxation characteristics indicate binding. This illustrates the potential use of bulk solution dielectric relaxation as the principle of operation for a biosensor.

Verified
Journal Article
Open access
PDF file
JHJohnathon Bryce Hunt
Johnathon Bryce Hunt
BMBrian A Mazzeo
Brian A Mazzeo
CSCarl Sorensen
Carl Sorensen
YHYuri Hovanski
Yuri Hovanski
Friction stir welding (FSW) is an advantageous solid-state joining process that is suitable for many materials in multiple industries. In an industrial setting, manufacturers are actively seeking faster welding speeds to increase throughput. Increasing welding speed limits the size of defect-free parameter windows, which may increase the frequency of defects. The push for faster welding speeds emphasizes the need for economical non-destructive evaluation (NDE) for FSW, like any other type of welding. This work introduces a generalized defect detection method that recognizes the stochastic nature of the FSW process, and that can be generally applied to FSW of a material across a dynamic range of process parameters and welding conditions. When applied to aluminum friction stir-welded blanks at speeds ranging from 1500 to 3000 mm/min with varying ranges of tool tilts, the methodology proved 100% effective at positive detection when defects were present with zero scrap rate. Furthermore, additional development demonstrated the proposed stochastic approach can be used to detect the spatial location of a defect within a weld with 94% detection accuracy and a 4.2% scrap rate.