Jorge Antonio Gonzalez-Sanchez

Dr. Jorge Antonio Gonzalez-Sanchez

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2008 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
EGE. García-Ochoa
E. García-Ochoa
JGJorge Antonio Gonzalez-Sanchez
Jorge Antonio Gonzalez-Sanchez
NAN. Acuña
N. Acuña
JEJ. Euan
J. Euan

29 April 2008 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
EGE. García-Ochoa
E. García-Ochoa
JGJorge Antonio Gonzalez-Sanchez
Jorge Antonio Gonzalez-Sanchez
FCF. Corvo
F. Corvo
ZUZ. Usagawa
Z. Usagawa
LDL. Dzib-Pérez
L. Dzib-Pérez
AVAbel Castañeda Valdés
Abel Castañeda Valdés

1 January 2024 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
Carlos Poblano SalasCarlos Poblano Salas
Carlos Poblano Salas
JHJohn Henao
John Henao
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur
PFPaola Forero-Sossa
Paola Forero-Sossa
Diego G Espinosa-ArbelaezDiego G Espinosa-Arbelaez
Diego G Espinosa-Arbelaez
IPIdelfonso E. Pech-Pech
Idelfonso E. Pech-Pech

28 June 2022 in Metals
Verified
Journal Article
Open access
PDF file
HGHeriberto Granados
Heriberto Granados
VMVictor Hugo Morelos
Victor Hugo Morelos
Antonio ContrerasAntonio Contreras
Antonio Contreras
Francisco Fernando Curiel LopezFrancisco Fernando Curiel Lopez
Francisco Fernando Curiel Lopez
RGRafael García-Hernández
Rafael García-Hernández
ECEduardo Cortés
Eduardo Cortés
The stress corrosion cracking (SCC) behavior of aged plates of Inconel 600 welded to Inconel 600 plates in the as-received condition was studied using the slow strain rate test (SSRT) in two sodium containing electrolytes at 25 and 80 °C. The aged plate was used to simulate damage by the operation service. Electrochemical noise (EN) was used to monitor the SCC. The plates were gas metal arc welded (GMAW) employing ERNiCrMo-3 and ER310 filler wires along with 95% Ar + 3% N2 + 2% O2 and 97% Ar + 3% N2 as the shielding gas, respectively. The microstructure of the welded joints was characterized using optical and scanning electron microscopy. The results of the SCC revealed that when sodium thiosulfate was used, the loss in plasticity was higher in the NiCrMo-3 joint with around a 20 percent decrease. Conversely, in the 310 welds, the loss in plasticity was higher in the sodium hydroxide, which diminished by 12 percent. A few secondary microcracks were observed in the transversal section in specimens of both welds. The results of the EN showed an increase in the potential and current when the sample reached the tensile strength and then decreased when the neck was formed; these changes indicate that some events occurred during the SSRT. The EN data showed two types of corrosion: general corrosion for NiCrMo-3 and mixed corrosion for the 310 welded joint in both environments. Electrochemical polarization was also employed to understand the mechanism of SCC.

1 May 2023 in Materials Science
Verified
Journal Article
Closed access
PDF file
YMY. Martinez-Galvan
Y. Martinez-Galvan
LDL. Dzib-Perez
L. Dzib-Perez
MGM. Garcia-Renteria
M. Garcia-Renteria
OBO. Bilyy
O. Bilyy
VLV. Lopez-Morelos
V. Lopez-Morelos
JGJorge Antonio Gonzalez-Sanchez
Jorge Antonio Gonzalez-Sanchez

30 November 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MAMartín Aguirre-Pulido
Martín Aguirre-Pulido
JGJorge Antonio Gonzalez-Sanchez
Jorge Antonio Gonzalez-Sanchez
LPLuis Román Dzib Pérez
Luis Román Dzib Pérez
MSMontserrat Soria-Castro
Montserrat Soria-Castro
AAAlejandro Avila-Ortega
Alejandro Avila-Ortega
WTWilliam Talavera-Pech
William Talavera-Pech
In this paper, a controlled-release system of caffeine as a corrosion inhibitor was obtained by encapsulating it in MCM-41 silica nanoparticles coated with a poly(β-amino ester) (PbAE), a pH-sensible polymer. Encapsulation was verified using Fourier transform infrared spectroscopy (FTIR) and thermogravimetry (TGA). The release of caffeine from the nanocontainers was analyzed in electrolytes with pH values of 4, 5, and 7 using UV–Vis, showing a 21% higher release in acidic electrolytes than in neutral electrolytes, corroborating its pH sensitivity. Electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization were used to determine the inhibition mode and efficiency of the encapsulated and free caffeine. The caffeine released from the nanocontainers showed the highest efficiency, which was 85.19%. These results indicate that these nanocontainers could have potential use in smart anticorrosion coating applications.