Maylis Lavayssière

Dr. Maylis Lavayssière

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KSKevin Sanchez
Kevin Sanchez
BABilel Achour
Bilel Achour
ACAnthony Coustou
Anthony Coustou
ALAurélie Lecestre
Aurélie Lecestre
SCSamuel Charlot
Samuel Charlot
PPPatrick PONS
Patrick PONS
Blast waves generated by energetic materials involve very fast time variations in the pressure. One important issue for blast wave metrology is the accurate measurement (typical precision in the range of ±5% or better) of the static overpressure peak. For most near field configurations, this measurement requires ultra-fast sensors with response times lower than a few microseconds. In this paper, we design, model, fabricate and characterize a new ultra-fast sensor using piezo-resistive gauges at the center of a miniaturized and rectangular silicon membrane. When a pressure step of 10 bar is applied to the membrane, the signal delivered to the sensor output presents dampened oscillations, with a resonant frequency of 20.6 MHz and quality factor of 24,700 ns after the arrival of the shock wave. After removing undesirable drifts that appear after 700 ns, we may expect the sensor to have a response time (at ±5%) of 1.2 µs. Consequently, the proposed pressure sensor could be advantageously used for the accurate measurement of static overpressure peaks in blast wave experiments.

4 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SMSébastien Maqueda
Sébastien Maqueda
JPJulien Perchoux
Julien Perchoux
CTClément Tronche
Clément Tronche
JIJ. J. Imas
J. J. Imas
MGMarc Genetier
Marc Genetier
Yohan BarbarinYohan Barbarin
Yohan Barbarin
In this paper, we demonstrate that a compact and inexpensive interferometric sensor based on the self-mixing effect in the laser cavity can be used for the characterization of shock waves. The sensor measures the changes in the refractive index induced by the shock wave. It is based on the self-mixing interferometry scheme. We describe the architecture of the dynamic sensor and the design of the experimental setup used for the characterization that involves a shock tube. Thus, we detail the experimental measurements for shock wave pressure amplitude of 5 bar and address their interpretation with regard to the most admitted models for acousto-optics.

17 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JMJérémi MAPAS
Jérémi MAPAS
LALEFRANCOIS Alexandre
LEFRANCOIS Alexandre
HAHervé AUBERT
Hervé AUBERT
SCSacha Comte
Sacha Comte
Yohan BarbarinYohan Barbarin
Yohan Barbarin
ADAlexandre Dore
Alexandre Dore
In this paper, a neural network approach is applied for solving an electromagnetic inverse problem involving solid dielectric materials subjected to shock impacts and interrogated by a millimeter-wave interferometer. Under mechanical impact, a shock wave is generated in the material and modifies the refractive index. It was recently demonstrated that the shock wavefront velocity and the particle velocity as well as the modified index in a shocked material can be remotely derived from measuring two characteristic Doppler frequencies in the waveform delivered by a millimeter-wave interferometer. We show here that a more accurate estimation of the shock wavefront and particle velocities can be obtained from training an appropriate convolutional neural network, especially in the important case of short-duration waveforms of few microseconds.

16 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MLMaylis Lavayssière
Maylis Lavayssière
LALEFRANCOIS Alexandre
LEFRANCOIS Alexandre
BCBernard Crabos
Bernard Crabos
MGMarc Genetier
Marc Genetier
MDMaxime Daudy
Maxime Daudy
PPPatrick PONS
Patrick PONS
This paper proposes two ways to improve pressure measurement in air-blast experimentations, mostly for close-in detonations defined by a small-scaled distance below 0.4 m.kg−1/3. Firstly, a new kind of custom-made pressure probe sensor is presented. The transducer is a piezoelectric commercial, but the tip material has been modified. The dynamic response of this prototype is established in terms of time and frequency responses, both in a laboratory environment, on a shock tube, and in free-field experiments. The experimental results show that the modified probe can meet the measurement requirements of high-frequency pressure signals. Secondly, this paper presents the initial results of a deconvolution method, using the pencil probe transfer function determination with a shock tube. We demonstrate the method on experimental results and draw conclusions and prospects.

22 March 2019
Verified
Book Chapter
Closed access
PDF file
MLMaylis Lavayssière
Maylis Lavayssière
JLJ. Luc
J. Luc
ALA. Lefrançois
A. Lefrançois

18 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
JVJulien Veyrunes
Julien Veyrunes
JRJérôme Riondet
Jérôme Riondet
AFAndré Ferrand
André Ferrand
MLMaylis Lavayssière
Maylis Lavayssière
LALEFRANCOIS Alexandre
LEFRANCOIS Alexandre
PPPatrick PONS
Patrick PONS
The development of new ultra-fast sensors for pressure air blast monitoring requires taking into account the very short rise time of pressure occurring during explosion. Simulations show here that the dynamic mechanical behavior of membrane-based sensors depends significantly on this rise time when the fundamental mechanical resonant frequency of the membrane is higher than 10 MHz.