Blast waves generated by energetic materials involve very fast time variations in the pressure. One important issue for blast wave metrology is the accurate measurement (typical precision in the range of ±5% or better) of the static overpressure peak. For most near field configurations, this measurement requires ultra-fast sensors with response times lower than a few microseconds. In this paper, we design, model, fabricate and characterize a new ultra-fast sensor using piezo-resistive gauges at the center of a miniaturized and rectangular silicon membrane. When a pressure step of 10 bar is applied to the membrane, the signal delivered to the sensor output presents dampened oscillations, with a resonant frequency of 20.6 MHz and quality factor of 24,700 ns after the arrival of the shock wave. After removing undesirable drifts that appear after 700 ns, we may expect the sensor to have a response time (at ±5%) of 1.2 µs. Consequently, the proposed pressure sensor could be advantageously used for the accurate measurement of static overpressure peaks in blast wave experiments.
Dynamic measurements of shock and detonation velocities are performed using long chirped fiber Bragg gratings (CFBGs). Such thin probes, with a diameter of typically 125 µm or even 80 µm can be directly inserted into high-explosive (HE) samples or simply glued laterally. During the detonation, the width of the optical spectrum is continuously reduced by the propagation of the wave-front, which physically shortens the CFBG. The light power reflected back shows a ramp-down type signal, from which the wave-front position is obtained as a function of time, thus yielding a detonation velocity profile. A calibration procedure was developed, with the support of optical simulations, to cancel out the optical spectrum distortions from the different optical components and to determine the wavelength-position transfer function of the CFBG. The fitted slopes of the X–T diagram give steady detonation velocity values which are in very good agreement with the classical measurements obtained from discrete electrical shorting pins (ESP). The main parameters influencing the uncertainties on the steady detonation velocity value measured by CFBG are discussed. To conclude, different HE experimental configurations tested at CEA (Commissariat à l’Energie Atomique et aux Energies Alternatives) are presented: bare cylindrical sticks, wedges for shock-to-detonation transitions (SDT), spheres, a cast-cured stick around a CFBG, and a detonation wave-front profile configuration.
In this paper, a neural network approach is applied for solving an electromagnetic inverse problem involving solid dielectric materials subjected to shock impacts and interrogated by a millimeter-wave interferometer. Under mechanical impact, a shock wave is generated in the material and modifies the refractive index. It was recently demonstrated that the shock wavefront velocity and the particle velocity as well as the modified index in a shocked material can be remotely derived from measuring two characteristic Doppler frequencies in the waveform delivered by a millimeter-wave interferometer. We show here that a more accurate estimation of the shock wavefront and particle velocities can be obtained from training an appropriate convolutional neural network, especially in the important case of short-duration waveforms of few microseconds.
This paper proposes two ways to improve pressure measurement in air-blast experimentations, mostly for close-in detonations defined by a small-scaled distance below 0.4 m.kg−1/3. Firstly, a new kind of custom-made pressure probe sensor is presented. The transducer is a piezoelectric commercial, but the tip material has been modified. The dynamic response of this prototype is established in terms of time and frequency responses, both in a laboratory environment, on a shock tube, and in free-field experiments. The experimental results show that the modified probe can meet the measurement requirements of high-frequency pressure signals. Secondly, this paper presents the initial results of a deconvolution method, using the pencil probe transfer function determination with a shock tube. We demonstrate the method on experimental results and draw conclusions and prospects.
When a dielectric material undergoes mechanical impact, it generates a shock wave, causing changes in its refractive index. Recent demonstrations have proven that the modified refractive index can be determined remotely using a millimeter-wave interferometer. However, these demonstrations are based on the resolution of an inverse electromagnetic problem, which assumes that the losses in the material are negligible. This restrictive assumption is overcome in this article, in which a new approach is proposed to solve the inverse electromagnetic problem in lossy and shocked dielectric materials. Our methodology combines a one-dimensional convolutional neural network architecture, namely Inverse problem of Lossless or Lossy Shocked Wavefront Network (ILSW-Net), with a nonlinear optimization technique based on the Nelder–Mead algorithm to estimate losses within dielectric materials under a mechanical impact. Experimental results for both simulated and real signals show that our method can successfully predict the velocities and the refractive index while accurately estimating the shock wavefront.
In this study, we investigated the capacitive effect and the electromagnetic coupling on the measurement chain induced by impact experiments with a gas gun or powder gun. Reduced bandwidth and noise were noticed on experimental signals. Rogowski coil measurements were added on the cables to characterize the electromagnetic coupling. The perturbation currents on the cables were quantified depending on the configuration. The gauge, the transmission line and the conditioning system were modeled. The calculations reproduced the electrical wave arrival time, the transmission line transfer impedance and the conditioning system transfer impedance; and the bandwidth limitation has been displayed. A capacitive effect with the piezoresistive manganin gauge embedded into the sample was identified, depending on the experimental setup.