David Alberto Ojeda

Dr. David Alberto Ojeda


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
CACristina Gabriela Ayala
Cristina Gabriela Ayala
FVFernando Vinicio Valencia
Fernando Vinicio Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
HSHugo Salazar
Hugo Salazar
DODavid Alberto Ojeda
David Alberto Ojeda
Background: The need to improve gait emulation in people with amputation has driven the development of customized prosthetic mechanisms. This study focuses on the design and validation of a mechanism for external knee joint prostheses, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. Objective: The objective is to design a mechanism that accurately reproduces the evolution of the ICR trajectory, thereby improving stability and reducing the user’s muscular effort. Methods: An exploratory methodology was employed, utilizing computer-aided design (CAD), kinematic simulations, and rapid prototyping through 3D printing. Multiple configurations of four- and six-bar mechanisms were evaluated to determine the ICR trajectory and compare it with a reference model obtained in the laboratory from a specific subject, using MATLAB-2023a and the Fréchet distance as an error metric. Results: The results indicated that the four-bar mechanism, with the incorporation of a simple gear train, achieved a more accurate emulation of the ICR trajectory, reaching a minimum error of 6.87 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during gait. It can be concluded that integrating the mechanism with the gear train significantly enhances its functionality, making it a viable alternative for the development of external knee prostheses for people with transfemoral amputation, based on the ICR of the contralateral leg.

29 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
CACristina Gabriela Ayala
Cristina Gabriela Ayala
FVFernando Valencia
Fernando Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
HSHugo Salazar
Hugo Salazar
DODavid Alberto Ojeda
David Alberto Ojeda
: The need to improve gait emulation in patients with transfemoral amputation has led to the development of customized prosthetic mechanisms. This study focuses on the design and validation of an external knee joint prosthesis mechanism, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. The goal is to design a mechanism that closely follows the evolution of the ICR path, improving stability and reducing the user's muscle effort. An exploratory methodology was applied, using computer-aided design (CAD), kinematic simulations, and rapid prototyping with 3D printing. Several four-bar and six-bar mechanism configurations were evaluated by determining their ICR trajectories and comparing them to a reference model obtained in the lab from a specific patient, using MATLAB and Fréchet distance as the error metric. The results showed that the optimized four-bar mechanism, with the addition of gears, achieved the highest accuracy in matching the ICR trajectory, with a minimum error of 5 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during walking. It is concluded that optimizing the mechanism design based on the ICR significantly improves functionality and supports its clinical implementation and impact on users’ quality of life.

7 January 2026 in Biomechanics
Verified
Journal Article
Open access
PDF file
FVFernando Vinicio Valencia
Fernando Vinicio Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
DODavid Alberto Ojeda
David Alberto Ojeda
HSHugo Salazar
Hugo Salazar
Objective: The purpose of this study is to develop a mechatronic device capable of characterizing the kinematics of the knee joint, based on the acquisition and analysis of data focused on the knee joint point. Methods: A mechatronic device was designed using dimensional data from a participant’s lower limb (1.59 m, 57 kg), obtained through 3D scanning. The device, based on a proportional mechanism aligned with anatomical reference points, allows the evolution of the knee joint pivot point (PPKJ) to be recorded. Ten healthy subjects (aged 22–26 years, height 1.50–1.63 m, body mass 48–59 kg) were selected for testing. The device was placed on each knee to record joint trajectories during squats. The trajectories were classified into two groups: extension to flexion and flexion to extension. For each group, the average trajectory was calculated. Results: Forty PPKJ trajectories were obtained, divided into two sets: extension to flexion with a range of 8° to 51.3° and flexion to extension with a range of 6.7° to 56.83°, which allowed the mean trajectory and cubic polynomial regression to be calculated as the best approximation for characterizing the trajectory of the instantaneous center of rotation of the knee joint. Conclusions: The developed mechatronic device offers an accessible and non-invasive solution for recording the trajectory of the knee joint pivot point in individuals with characteristics like those in the study. This alternative approach could improve the representation of knee kinematics in the design of customized prostheses, exoskeletons, and rehabilitation devices for lower limbs.

21 July 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
FVFernando Vinicio Valencia
Fernando Vinicio Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
DODavid Alberto Ojeda
David Alberto Ojeda
Background: The natural motion of the human knee involves a combination of rotation and translation, resulting in a variable Instantaneous Center of Rotation (ICR) throughout the gait cycle. Traditional prosthetic knee designs often fail to reproduce this complex kinematic behavior. Objectives: This study aims to propose a customized, biomimetic knee mechanism through the synthesis of a four-bar linkage capable of approximating the physiological ICR trajectory with high precision. Methods: A Genetic Algorithm (GA) was implemented to optimize the geometric parameters of the four-bar mechanism, specifically its link lengths and inter-link angles. The optimization process is based on Freudenstein’s equation, which analytically relates the input and output angles of the linkage to the lengths of its links. The desired ICR trajectory was derived from experimental data, and the objective function minimized the Euclidean error between the generated and target trajectories. Results: The proposed method yielded customized mechanisms that closely approximate the target ICR curves, achieving an overall mean Euclidean tracking error of 1.95% (±1.68%) across diverse patient profiles, with a best-case optimization error as low as 0.355%. Furthermore, the GA demonstrated high computational efficiency, converging on optimal geometric configurations in an average execution time of just 3.98 min. Conclusions: These numerical results validate the robustness of the GA in navigating the design space while strictly adhering to kinematic constraints, Grashof’s condition, and anatomical motion limits. The integration of Freudenstein’s equation with GA-based optimization techniques enables the customized synthesis of four-bar linkages with a high capacity to reproduce the physiological kinematics of the knee. This computational approach could be highly beneficial for the design of polycentric knee prostheses, as it reduces design and manufacturing time by providing the initial parameters for the development of the four-bar mechanism, ultimately ensuring a better biomechanical fit between prosthetic and natural human movement.