Background: The need to improve gait emulation in people with amputation has driven the development of customized prosthetic mechanisms. This study focuses on the design and validation of a mechanism for external knee joint prostheses, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. Objective: The objective is to design a mechanism that accurately reproduces the evolution of the ICR trajectory, thereby improving stability and reducing the user’s muscular effort. Methods: An exploratory methodology was employed, utilizing computer-aided design (CAD), kinematic simulations, and rapid prototyping through 3D printing. Multiple configurations of four- and six-bar mechanisms were evaluated to determine the ICR trajectory and compare it with a reference model obtained in the laboratory from a specific subject, using MATLAB-2023a and the Fréchet distance as an error metric. Results: The results indicated that the four-bar mechanism, with the incorporation of a simple gear train, achieved a more accurate emulation of the ICR trajectory, reaching a minimum error of 6.87 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during gait. It can be concluded that integrating the mechanism with the gear train significantly enhances its functionality, making it a viable alternative for the development of external knee prostheses for people with transfemoral amputation, based on the ICR of the contralateral leg.
Objective: The purpose of this study is to develop a mechatronic device capable of characterizing the kinematics of the knee joint, based on the acquisition and analysis of data focused on the knee joint point. Methods: A mechatronic device was designed using dimensional data from a participant’s lower limb (1.59 m, 57 kg), obtained through 3D scanning. The device, based on a proportional mechanism aligned with anatomical reference points, allows the evolution of the knee joint pivot point (PPKJ) to be recorded. Ten healthy subjects (aged 22–26 years, height 1.50–1.63 m, body mass 48–59 kg) were selected for testing. The device was placed on each knee to record joint trajectories during squats. The trajectories were classified into two groups: extension to flexion and flexion to extension. For each group, the average trajectory was calculated. Results: Forty PPKJ trajectories were obtained, divided into two sets: extension to flexion with a range of 8° to 51.3° and flexion to extension with a range of 6.7° to 56.83°, which allowed the mean trajectory and cubic polynomial regression to be calculated as the best approximation for characterizing the trajectory of the instantaneous center of rotation of the knee joint. Conclusions: The developed mechatronic device offers an accessible and non-invasive solution for recording the trajectory of the knee joint pivot point in individuals with characteristics like those in the study. This alternative approach could improve the representation of knee kinematics in the design of customized prostheses, exoskeletons, and rehabilitation devices for lower limbs.
Understanding knee kinematics during gait is essential for the design of prostheses, orthoses, and biomimetic mechanisms. In many biomechanical analyses, tibiofemoral motion is simplified to the sagittal plane, allowing the locus of the instantaneous center of rotation (ICR) to describe joint kinematics derived from the instantaneous axis of rotation (IAR). However, it remains unclear whether ICR trajectories obtained from simplified flexion–extension tasks can represent those observed during gait. This study analyzes the sagittal-plane trajectory of the tibiofemoral ICR during gait swing, standing swing, seated swing, and squat. Motion data from 21 healthy participants were captured using videogrammetry, and the instantaneous axis of rotation (IAR) was computed from homogeneous transformation matrices using the Mozzi–Chasles theorem. Sagittal-plane ICR trajectories were derived and compared within subjects across tasks. Significant differences were found between gait and all other movements in both trajectory shape and spatial position. The shape metric (S), which quantifies differences in trajectory geometry, showed mean values ranging from 0.82 to 1.04 with very large effect sizes (Cohen’s d = 2.90 to 4.47, p < 0.0001). The centroid distance metric (M), which measures the overall spatial displacement between trajectories, indicated positional differences ranging from 8.15 mm to 12.37 mm between trajectories also showing very large effect sizes (Cohen’s = 1.72–3.40, p < 0.0001). Additionally, the mean deviation of the IAR from the sagittal plane ranged from 14° to 18° during gait, whereas smaller deviations were observed in non–weight-bearing swing movements. These results demonstrate that tibiofemoral ICR trajectories are task-dependent and that simplified flexion–extension tasks do not fully reproduce the knee kinematics observed during gait. Consequently, the use of gait-derived ICR trajectories, together with their variability, provides a more suitable basis for the design and optimization of polycentric mechanisms, enabling the development of devices that more closely replicate real biomechanics and are potentially better adapted to the user.
This paper presents the preliminary results of a study on implementing Industry 4.0 in metallurgical factories. It showed that adopting Industry 4.0 technologies generates a productive environment characterized by real-time sensing, with high adaptability, flexibility, self-learning capacity, and fault tolerance. In the context of the Ecuadorian industry, particularly in micro, small, and medium-sized enterprises (MSMEs), there is limited integration of industrial technologies, both at the software and hardware levels. Additionally, many factories do not perceive the relevance of implementing solutions based on Industry 4.0 in key areas such as production, quality control, and maintenance. The study presents three case studies of metalworking factories that emerged as small locksmith workshops and analyzes the challenges related to incorporating new know-how in these industries. The findings concluded that Industry 4.0 has transformative potential for the value chain, facilitating the development of innovative products and services.
Se diseña un mecanismo de articulación de rodilla para una prótesis externa, es decir el prototipo puede ser usado en personas con amputaciones del tipo transfemoral, con el fin de contribuir a la sociedad al brindar soluciones a favor de las personas con capacidades especiales. Se toma en consideración los aspectos más relevantes para el desarrollo de la marcha humana protésica normal como son: nivel de actividad física, medidas antropométricas, materiales adecuados para la construcción, estabilidad y confort entre otros. Luego de realizar un análisis extensivo y proceso de diseño y rediseño se construyó un prototipo funcional, que en el futuro podrá ser probado en personas que así lo requieran.