Wei Ding

Mr. Wei Ding

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NSNing Shao
Ning Shao
QCQing Chen
Qing Chen
YDYuzhan Dong
Yuzhan Dong
WDWei Ding
Wei Ding
LWLei Wang
Lei Wang
Fault diagnosis is critical to ensuring the stable and reliable operation of power systems. Currently, power system fault diagnosis faces two challenges. One is that fault diagnosis methods do not fully consider power system scale and topology changes. The other is that the uncertainty of alarm information yields inaccurate fault diagnosis results. To address the above problems, this article proposes a fault diagnosis method based on intuitionistic fuzzy sets and incidence matrices. First, the fault area is searched, and its incidence matrices are constructed. Then, the intuitionistic fuzzy numbers are assigned to the incidence matrices using proposed assignment rules to form intuitionistic fuzzy incidence matrices while considering the missing alarm information. Finally, the fault diagnosis model based on intuitionistic fuzzy incidence matrices and its reasoning process are utilized to diagnose the fault area. The case studies illustrate that the proposed method has high accuracy and fault tolerance. The fault diagnosis model is independent of the power system scale and can adapt to topology changes. Moreover, the reasoning process is low-complexity and easy to implement. The proposed method is demonstrated to satisfy the demand for online fault diagnosis in large-scale power systems.

7 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WDWei Ding
Wei Ding
QCQing Chen
Qing Chen
Yuzhan DongYuzhan Dong
Yuzhan Dong
NSNing Shao
Ning Shao
In order to improve the efficiency of the devices’ fault diagnosis of the protection systems of intelligent substation, a fault diagnosis method based on a gradient boosting decision tree (GBDT) was proposed. Using the integrated alarm information, the device self-checking information, the link information of generic object-oriented substation event (GOOSE) and sampled value (SV) and the sampling value information generated during the fault of the protection system, the fault feature information set is constructed. According to different fault characteristics, the protection system faults are classified into simple faults and complex faults to improve the diagnosis efficiency. Using GBDT training rules, a fault diagnosis model of protection system based on GBDT is established and fault diagnosis steps are given. This study takes a 110 kV intelligent substation in southern China as an example, to verify the effectiveness and accuracy of the proposed fault diagnosis method, and compared it with the existing methods in terms of the accuracy. The diagnostic accuracy in the case of false alarms and the case of multiple faults are verified. The results show that the method can meet the practical engineering application.

27 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yuzhan DongYuzhan Dong
Yuzhan Dong
QCQing Chen
Qing Chen
WDWei Ding
Wei Ding
NSNing Shao
Ning Shao
GCGuanting Chen
Guanting Chen
Guanbin LiGuanbin Li
Guanbin Li
Digital twin technology aims to build a map of physical entities in virtual space, and simulate the real-time state and dynamic characteristics of physical devices through bi-directional interactive data flow. In order to guarantee the safe and stable operation of protection system equipment in intelligent substations and improve the efficiency of protection system operation and condition maintenance, this paper proposes a protection system state evaluation and fault prediction method based on digital twin technology. The architecture, application and operation control mode of digital twin technology in a real-time state analysis of a protection system are studied. The state evaluation model based on matter-element extension and the fault prediction model based on clustering algorithm are constructed. By analyzing the historical data of an intelligent station protection system in actual operation, a database that can be updated and corrected in real time is constructed. The effectiveness and accuracy of the state evaluation and fault prediction method are verified with actual cases, which can provide technical support for the operation and maintenance of the protection system.

20 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jinjie JiJinjie Ji
Jinjie Ji
QCQing Chen
Qing Chen
JMJinshuang Mu
Jinshuang Mu
XZXiaotong Zhou
Xiaotong Zhou
WDWei Ding
Wei Ding
In order to complete the function of power grid fault diagnosis accurately, rapidly and comprehensively, the power grid fault diagnosis system based on multi-data sources is proposed. The integrated system uses accident-level information, warning-level information and fault recording documents and outputs a complete diagnosis and tracking report. According to the timeliness of three types of information transmission, the system is divided into three subsystems: real-time processing system, quasi-real-time processing system and batch processing system. The complete work is realized through the cooperation between them. While a real-time processing system completes fault diagnosis of elements, it also screens out incorrectly operating protections and circuit breakers and judges the loss of accident-level information. Quasi-real-time system outputs reasons for incorrect actions of protections and circuit breakers under the premise of considering partial warning-level information missing. The batch processing system corrects diagnosis results of the real-time processing system and outputs fault details, including fault phases, types, times and locations of faulty elements. The simulation results and test show that the system can meet actual engineering requirements in terms of execution efficiency and fault diagnosis and tracking effect. It can be used as a reference for self-healing and maintenance of power grids and has a preferable application value.

23 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YSYe Sun
Ye Sun
QCQing Chen
Qing Chen
DXDan Xie
Dan Xie
NSNing Shao
Ning Shao
WDWei Ding
Wei Ding
Yuzhan DongYuzhan Dong
Yuzhan Dong
This paper puts forward a fault location method combining the improved matrix algorithm and the genetic tabu algorithm based on multi-source information in view of the limitation of existing fault location methods in active distribution networks, such as long-time consumption, low accuracy, and low tolerance performance. Firstly, the fault region location method is proposed to simplify the active distribution network model and reduce the matrix calculation dimension. Secondly, the improved matrix algorithm is proposed to locate the fault section, and a positioning result verification method is proposed to improve the tolerance performance. Finally, the genetic tabu algorithm is proposed to optimize suspicious fault sections when the verification is incorrect and obtain the positioning result. The simulation results show that the fault location method proposed in this paper locates faster and performs better in both accuracy and tolerance in different fault conditions than others.

15 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DXDan Xie
Dan Xie
QCQing Chen
Qing Chen
YSYe Sun
Ye Sun
NSNing Shao
Ning Shao
Yuzhan DongYuzhan Dong
Yuzhan Dong
WDWei Ding
Wei Ding
One of the main factors in triggering cascading outages is the unexpected tripping of backup protection caused by load encroachment (LE). Hence, LE should be identified quickly to avoid unexpected tripping. This paper proposes a fast LE identification method based on the wide-area measurement system (WAMS), applicable to transmission grids with high wind power penetration. Firstly, based on the improved shortest path algorithm, the method searches for critical lines greatly affected by the LE to determine the collected range of wide-area information. Then, by analyzing the hidden dangers of the existing calculation method for the active power estimation value (APEV) in the power system with wind farms, a fast calculation method of the APEV based on the WAMS is proposed to ensure that the existing LE identification criterion is still applicable in the high-penetration system of wind power. Finally, based on the PSASP platform, the wind farm model is integrated into the IEEE 39-bus New England system for simulation. The simulation results show that the method proposed in this paper can quickly search for the critical line set (CLS) and accurately identify the LE under high wind power penetration, effectively avoiding the unexpected tripping of backup protection and preventing cascading outages.