Dan Xie

Ms. Dan Xie


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
NSNing Shao
Ning Shao
QCQing Chen
Qing Chen
CYChengao Yu
Chengao Yu
DXDan Xie
Dan Xie
YSYe Sun
Ye Sun
The incorrect operation of protective relays and circuit breakers will significantly compromise the safety and stability of power systems. To promptly detect the faults of the relay protection system and the circuit breakers in time and to ensure the operational reliability of these protective devices, this paper proposes a fault tracing method for a relay protection system–circuit breaker based on improved Random Forest. Firstly, an analysis is conducted to identify the causes of incorrect operation of the protective relay and the circuit breaker. The fault types and corresponding alarm messages for the relay protection system and the circuit breaker are categorized, and the alarm feature set is constructed. Then, the Random Forest is improved and trained to develop the fault tracking model. Finally, the operation evaluation process is developed to determine the incorrect operations of the protective relay and the circuit breaker, and the fault tracking model and fault tracking process are then employed to locate the faults of the relay protection system and the circuit breaker. The experimental results demonstrate the method’s capability to accurately track faults in the relay protection system and the circuit breaker, thereby assisting operation and maintenance personnel in troubleshooting and highlighting its promising practical potential.

23 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YSYe Sun
Ye Sun
QCQing Chen
Qing Chen
DXDan Xie
Dan Xie
NSNing Shao
Ning Shao
WDWei Ding
Wei Ding
Yuzhan DongYuzhan Dong
Yuzhan Dong
This paper puts forward a fault location method combining the improved matrix algorithm and the genetic tabu algorithm based on multi-source information in view of the limitation of existing fault location methods in active distribution networks, such as long-time consumption, low accuracy, and low tolerance performance. Firstly, the fault region location method is proposed to simplify the active distribution network model and reduce the matrix calculation dimension. Secondly, the improved matrix algorithm is proposed to locate the fault section, and a positioning result verification method is proposed to improve the tolerance performance. Finally, the genetic tabu algorithm is proposed to optimize suspicious fault sections when the verification is incorrect and obtain the positioning result. The simulation results show that the fault location method proposed in this paper locates faster and performs better in both accuracy and tolerance in different fault conditions than others.

21 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NSNing Shao
Ning Shao
QCQing Chen
Qing Chen
DXDan Xie
Dan Xie
YSYe Sun
Ye Sun
CYChengao Yu
Chengao Yu
Fuzzy and temporal reasoning can effectively improve the accuracy of fault diagnosis methods. However, there are challenges in practical applications, such as missing alarm messages, temporal reasoning with complex calculations, and complex modeling processes. Therefore, this study proposes an improved temporal fuzzy reasoning spiking neural P (ITFRSNP) system for power system fault diagnosis. First, the ITFRSNP system and its reasoning method are proposed to perform association reasoning between confidence degrees and temporal constraints. Second, a general fault diagnosis model and process are developed based on the ITFRSNP system to diagnose various faulty components and simplify the modeling process. In addition, a search method is provided for identifying suspected faulty components, considering the missing alarm message of the circuit breaker. Simulation results of fault cases demonstrate that the proposed method exhibits high accuracy and fault tolerance. It can precisely identify faulty components despite incorrect operations or inaccurate alarm messages of protective relays and circuit breakers. Moreover, the search method effectively narrows down the diagnostic scope without missing suspected faulty components in scenarios where alarms from boundary circuit breakers are missing, thereby enhancing the fault diagnosis efficiency. The fault diagnosis model features a straightforward structure and reasoning process with minimal computational complexity, making it suitable for real-time diagnosis of complex faults within power systems.

15 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DXDan Xie
Dan Xie
QCQing Chen
Qing Chen
YSYe Sun
Ye Sun
NSNing Shao
Ning Shao
Yuzhan DongYuzhan Dong
Yuzhan Dong
WDWei Ding
Wei Ding
One of the main factors in triggering cascading outages is the unexpected tripping of backup protection caused by load encroachment (LE). Hence, LE should be identified quickly to avoid unexpected tripping. This paper proposes a fast LE identification method based on the wide-area measurement system (WAMS), applicable to transmission grids with high wind power penetration. Firstly, based on the improved shortest path algorithm, the method searches for critical lines greatly affected by the LE to determine the collected range of wide-area information. Then, by analyzing the hidden dangers of the existing calculation method for the active power estimation value (APEV) in the power system with wind farms, a fast calculation method of the APEV based on the WAMS is proposed to ensure that the existing LE identification criterion is still applicable in the high-penetration system of wind power. Finally, based on the PSASP platform, the wind farm model is integrated into the IEEE 39-bus New England system for simulation. The simulation results show that the method proposed in this paper can quickly search for the critical line set (CLS) and accurately identify the LE under high wind power penetration, effectively avoiding the unexpected tripping of backup protection and preventing cascading outages.