Compared with the AC microgrids, the advantages of DC microgrids are notable. However, the development of DC microgrids is being constrained by the lack of mature protection schemes. As the foundation of designing protection schemes, the existing fault analysis almost all focused on the fault characteristics of voltage source converters (VSCs) and ignored other generators. While, in DC microgrids with high permeability of photovoltaic (PV) powers, the impacts from PV powers should be paid enough attention. In this paper, the cable fault characteristics of the PV powers are analyzed in detail and both the pole-to-ground fault and the pole-to-pole fault are involved. The fault processes are divided into several stages and the fault circuits and main equations are given for each stage. All the analysis are verified by the simulation model based on the PSCAD/EMTDC and with the help of simulation results, the two main challenges the protection system confronted with are emphasized and impacts of fault distance are analyzed. Finally, the paper proposes to employ a more reasonable converter structure and a transverse differential protection to overcome the main challenges, and the methods effectiveness is verified by the simulation.
13 July 2023 in IEEE Transactions on Power Delivery
Fault diagnosis is critical to ensuring the stable and reliable operation of power systems. Currently, power system fault diagnosis faces two challenges. One is that fault diagnosis methods do not fully consider power system scale and topology changes. The other is that the uncertainty of alarm information yields inaccurate fault diagnosis results. To address the above problems, this article proposes a fault diagnosis method based on intuitionistic fuzzy sets and incidence matrices. First, the fault area is searched, and its incidence matrices are constructed. Then, the intuitionistic fuzzy numbers are assigned to the incidence matrices using proposed assignment rules to form intuitionistic fuzzy incidence matrices while considering the missing alarm information. Finally, the fault diagnosis model based on intuitionistic fuzzy incidence matrices and its reasoning process are utilized to diagnose the fault area. The case studies illustrate that the proposed method has high accuracy and fault tolerance. The fault diagnosis model is independent of the power system scale and can adapt to topology changes. Moreover, the reasoning process is low-complexity and easy to implement. The proposed method is demonstrated to satisfy the demand for online fault diagnosis in large-scale power systems.
In order to improve the efficiency of the devices’ fault diagnosis of the protection systems of intelligent substation, a fault diagnosis method based on a gradient boosting decision tree (GBDT) was proposed. Using the integrated alarm information, the device self-checking information, the link information of generic object-oriented substation event (GOOSE) and sampled value (SV) and the sampling value information generated during the fault of the protection system, the fault feature information set is constructed. According to different fault characteristics, the protection system faults are classified into simple faults and complex faults to improve the diagnosis efficiency. Using GBDT training rules, a fault diagnosis model of protection system based on GBDT is established and fault diagnosis steps are given. This study takes a 110 kV intelligent substation in southern China as an example, to verify the effectiveness and accuracy of the proposed fault diagnosis method, and compared it with the existing methods in terms of the accuracy. The diagnostic accuracy in the case of false alarms and the case of multiple faults are verified. The results show that the method can meet the practical engineering application.
This paper presents a novel pilot protection scheme of DC cable line in voltage-source-converter (VSC) based multi-terminal DC (MTDC) grids, which utilizes a novel phase-mode transformation to decouple the bipolar DC cable current into six mode and it uses the stationary wavelet transform to extract the modulus maxima of fault initial traveling waves current (FITWC). With accurate amplitude and polarities of the FITWC being collected from the fault-detection devices located at each terminal, the proposed scheme can correctly determine the faulty segment and the faulty pole. In this paper, the ratio of amplitudes between sixth mode forward and backward travelling wave currents is used to judge the faulty segment and the polarity of fifth mode forward travelling wave current is used to identify the faulty pole. A four-terminal VSC-based MTDC grid was built in PSCAD/EMTDC to evaluate the performance of the fault-protection scheme. Simulation results for different cases demonstrate that the proposed protection scheme is robust against noise, and has been tested successfully for fault resistance of up to 400 Ω. Since the scheme merely needs the characteristics of FITWCs, the practical difficulties of detecting subsequent travelling waves are avoided. Moreover, only the state signal is needed to send to the other side in proposed scheme, so low communication speed can satisfy the requirement of relay protection and it does not need the data synchronization seriously.
The paper presents a new protection principle for double circuit transmission lines of bipolar HVDC transmission system. By comparing the magnitudes of fault component of voltages on the bipolar lines, the faulty line can be identified. By comparing the polarities of fault component of currents at the ends of the faulty line, the internal faults and external faults can be differentiated. The principle can be applied for bipolar neutral grounding at both ends and monopolar metallic return mode operation. Different conditions are considered to research the operating characteristic of the proposed protection criterions, including short circuit faults on AC-side bus, commutation failure, lightning stroke and short circuit faults on dc transmission lines with different positions and transition resistances. Simulations results show the selectivity, speed, sensitivity and reliability of the protection principle, and the sampling frequency requirement of measuring instruments in the protection scheme can be 10~ 100 kHz.
Digital twin technology aims to build a map of physical entities in virtual space, and simulate the real-time state and dynamic characteristics of physical devices through bi-directional interactive data flow. In order to guarantee the safe and stable operation of protection system equipment in intelligent substations and improve the efficiency of protection system operation and condition maintenance, this paper proposes a protection system state evaluation and fault prediction method based on digital twin technology. The architecture, application and operation control mode of digital twin technology in a real-time state analysis of a protection system are studied. The state evaluation model based on matter-element extension and the fault prediction model based on clustering algorithm are constructed. By analyzing the historical data of an intelligent station protection system in actual operation, a database that can be updated and corrected in real time is constructed. The effectiveness and accuracy of the state evaluation and fault prediction method are verified with actual cases, which can provide technical support for the operation and maintenance of the protection system.