Ning Shao

Mr. Ning Shao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WDWei Ding
Wei Ding
QCQing Chen
Qing Chen
Yuzhan DongYuzhan Dong
Yuzhan Dong
NSNing Shao
Ning Shao
In order to improve the efficiency of the devices’ fault diagnosis of the protection systems of intelligent substation, a fault diagnosis method based on a gradient boosting decision tree (GBDT) was proposed. Using the integrated alarm information, the device self-checking information, the link information of generic object-oriented substation event (GOOSE) and sampled value (SV) and the sampling value information generated during the fault of the protection system, the fault feature information set is constructed. According to different fault characteristics, the protection system faults are classified into simple faults and complex faults to improve the diagnosis efficiency. Using GBDT training rules, a fault diagnosis model of protection system based on GBDT is established and fault diagnosis steps are given. This study takes a 110 kV intelligent substation in southern China as an example, to verify the effectiveness and accuracy of the proposed fault diagnosis method, and compared it with the existing methods in terms of the accuracy. The diagnostic accuracy in the case of false alarms and the case of multiple faults are verified. The results show that the method can meet the practical engineering application.

27 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yuzhan DongYuzhan Dong
Yuzhan Dong
QCQing Chen
Qing Chen
WDWei Ding
Wei Ding
NSNing Shao
Ning Shao
GCGuanting Chen
Guanting Chen
Guanbin LiGuanbin Li
Guanbin Li
Digital twin technology aims to build a map of physical entities in virtual space, and simulate the real-time state and dynamic characteristics of physical devices through bi-directional interactive data flow. In order to guarantee the safe and stable operation of protection system equipment in intelligent substations and improve the efficiency of protection system operation and condition maintenance, this paper proposes a protection system state evaluation and fault prediction method based on digital twin technology. The architecture, application and operation control mode of digital twin technology in a real-time state analysis of a protection system are studied. The state evaluation model based on matter-element extension and the fault prediction model based on clustering algorithm are constructed. By analyzing the historical data of an intelligent station protection system in actual operation, a database that can be updated and corrected in real time is constructed. The effectiveness and accuracy of the state evaluation and fault prediction method are verified with actual cases, which can provide technical support for the operation and maintenance of the protection system.

31 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
NSNing Shao
Ning Shao
QCQing Chen
Qing Chen
CYChengao Yu
Chengao Yu
DXDan Xie
Dan Xie
YSYe Sun
Ye Sun
The incorrect operation of protective relays and circuit breakers will significantly compromise the safety and stability of power systems. To promptly detect the faults of the relay protection system and the circuit breakers in time and to ensure the operational reliability of these protective devices, this paper proposes a fault tracing method for a relay protection system–circuit breaker based on improved Random Forest. Firstly, an analysis is conducted to identify the causes of incorrect operation of the protective relay and the circuit breaker. The fault types and corresponding alarm messages for the relay protection system and the circuit breaker are categorized, and the alarm feature set is constructed. Then, the Random Forest is improved and trained to develop the fault tracking model. Finally, the operation evaluation process is developed to determine the incorrect operations of the protective relay and the circuit breaker, and the fault tracking model and fault tracking process are then employed to locate the faults of the relay protection system and the circuit breaker. The experimental results demonstrate the method’s capability to accurately track faults in the relay protection system and the circuit breaker, thereby assisting operation and maintenance personnel in troubleshooting and highlighting its promising practical potential.

23 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YSYe Sun
Ye Sun
QCQing Chen
Qing Chen
DXDan Xie
Dan Xie
NSNing Shao
Ning Shao
WDWei Ding
Wei Ding
Yuzhan DongYuzhan Dong
Yuzhan Dong
This paper puts forward a fault location method combining the improved matrix algorithm and the genetic tabu algorithm based on multi-source information in view of the limitation of existing fault location methods in active distribution networks, such as long-time consumption, low accuracy, and low tolerance performance. Firstly, the fault region location method is proposed to simplify the active distribution network model and reduce the matrix calculation dimension. Secondly, the improved matrix algorithm is proposed to locate the fault section, and a positioning result verification method is proposed to improve the tolerance performance. Finally, the genetic tabu algorithm is proposed to optimize suspicious fault sections when the verification is incorrect and obtain the positioning result. The simulation results show that the fault location method proposed in this paper locates faster and performs better in both accuracy and tolerance in different fault conditions than others.

21 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NSNing Shao
Ning Shao
QCQing Chen
Qing Chen
DXDan Xie
Dan Xie
YSYe Sun
Ye Sun
CYChengao Yu
Chengao Yu
Fuzzy and temporal reasoning can effectively improve the accuracy of fault diagnosis methods. However, there are challenges in practical applications, such as missing alarm messages, temporal reasoning with complex calculations, and complex modeling processes. Therefore, this study proposes an improved temporal fuzzy reasoning spiking neural P (ITFRSNP) system for power system fault diagnosis. First, the ITFRSNP system and its reasoning method are proposed to perform association reasoning between confidence degrees and temporal constraints. Second, a general fault diagnosis model and process are developed based on the ITFRSNP system to diagnose various faulty components and simplify the modeling process. In addition, a search method is provided for identifying suspected faulty components, considering the missing alarm message of the circuit breaker. Simulation results of fault cases demonstrate that the proposed method exhibits high accuracy and fault tolerance. It can precisely identify faulty components despite incorrect operations or inaccurate alarm messages of protective relays and circuit breakers. Moreover, the search method effectively narrows down the diagnostic scope without missing suspected faulty components in scenarios where alarms from boundary circuit breakers are missing, thereby enhancing the fault diagnosis efficiency. The fault diagnosis model features a straightforward structure and reasoning process with minimal computational complexity, making it suitable for real-time diagnosis of complex faults within power systems.

23 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
WLWeichao Li
Weichao Li
SWShouyuan Wu
Shouyuan Wu
FZFeng Zhang
Feng Zhang
NSNing Shao
Ning Shao
Electronic control strategies are pivotal in the evolution of power systems, which have higher requirements for power leveling and optimization, frequency safety, and frequency stability. In contrast, the core objectives of existing energy storage services are mostly limited to one function, which cannot fully meet the operational requirements of power systems. This paper presents research on a frequency security controller based on digital twin technology and aimed to enhance the safety of the system. The proposed controller can simultaneously smooth out active wind power fluctuations and optimize reactive power, participate in system frequency regulation, and improve system damping to damp low-frequency oscillations based on simulating the actual operating environment. Simulations also verify the effectiveness of the proposed controller in DIgSILENT/PowerFactory based on a two-area system. This active/reactive power-based system support service will bring new economic benefits to wind energy storage systems.