Costanza Cenerini

Ms. Costanza Cenerini

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2024 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
ASAnna Sabatini
Anna Sabatini
CCCostanza Cenerini
Costanza Cenerini
Luca VolleroLuca Vollero
Luca Vollero
DPDanilo Pietro Pau
Danilo Pietro Pau
Background: Continuous glucose monitoring (CGM) systems offer the advantage of noninvasive monitoring and continuous data on glucose fluctuations. This study introduces a new model that enables the generation of synthetic but realistic databases that integrate physiological variables and sensor attributes into a dataset generation model and this, in turn, enables the design of improved CGM systems. Methods: The presented approach uses a combination of physiological data and sensor characteristics to construct a model that considers the impact of these variables on the accuracy of CGM measures. A dataset of 500 sensor responses over a 15-day period is generated and analyzed using machine learning algorithms (random forest regressor and support vector regressor). Results: The random forest and support vector regression models achieved Mean Absolute Errors (MAEs) of 16.13 mg/dL and 16.22 mg/dL, respectively. In contrast, models trained solely on single sensor outputs recorded an average MAE of 11.01±5.12 mg/dL. These findings demonstrate the variable impact of integrating multiple data sources on the predictive accuracy of CGM systems, as well as the complexity of the dataset. Conclusions: This approach provides a foundation for developing more precise algorithms and introduces its initial application of Tiny Machine Control Units (MCUs). More research is recommended to refine these models and validate their effectiveness in clinical settings.

1 September 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ASAnna Sabatini
Anna Sabatini
ALAlfiero Leoni
Alfiero Leoni
Gil GonçalvesGil Gonçalves
Gil Gonçalves
Alessandro ZompantiAlessandro Zompanti
Alessandro Zompanti
MMMarco V. Marchetta
Marco V. Marchetta
Marco SantonicoMarco Santonico
Marco Santonico
The need for accurate information and the availability of novel tool and technological advances in agriculture have given rise to innovative autonomous systems. The aim is to monitor key parameters for optimal water and fertilizer management. A key issue in precision agriculture is the in situ monitoring of soil macronutrients. Here, a proof-of-concept study was conducted that tested two types of sensors capable of capturing both the electrochemical response of the soil and the electrical potential generated by the interaction between the soil and plants. These two sensors can be used to monitor large areas using a network approach, due to their small size and low power consumption. The voltammetric sensor (BIONOTE-L) proved to be able to characterize different soil samples. It was able, indeed, to provide a reproducible voltammetric fingerprint specific for each soil type, and to monitor the concentration of CaCl2 and NaCl in the soil. BIONOTE-L can be coupled to a device capable of capturing the energy produced by interactions between plants and soil. As a consequence, the functionality of the microsystem node when applied in a large-area monitoring network can be extended. Additional calibrations will be performed to fully characterize the instrument node, to implement the network, and to specialize it for a particular application in the field.

23 September 2025 in Computers in Human Behavior: Artificial Humans
Verified
Journal Article
Open access
CCCostanza Cenerini
Costanza Cenerini
FKFlavio Keller
Flavio Keller
GPGiorgio Pennazza
Giorgio Pennazza
MSMarco Santonico
Marco Santonico
LVLuca Vollero
Luca Vollero

2 August 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
CCCostanza Cenerini
Costanza Cenerini
ASAnna Sabatini
Anna Sabatini
Luca VolleroLuca Vollero
Luca Vollero
DPDanilo Pietro Pau
Danilo Pietro Pau
Diabetes presents a significant global health challenge, necessitating precise blood glucose monitoring for effective management. Continuous Glucose Monitoring (CGM) devices offer a minimally invasive approach, yet require accurate calibration models to improve reliability. This study investigates various neural network architectures for predicting time errors in CGM sensor readings, aiming for high accuracy and minimal computational burden. Using simulated data, models were trained and evaluated, with Legendre Memory Unit and Temporal Convolutional Network architectures emerging as promising candidates. With these architectures it was possible to lower the sensor's reading error to, respectively, 24.22 mg/dL and 25.34 mg/dL, decreasing the error by 40.6% and 37.9%. Furthermore, the study explores the impact of sensor calibration frequency on prediction accuracy, revealing optimal performance with calibrations once every 3 or 5 days, obtaining an error in the reading of approximately 16 and 15 mg/dL. These findings underscore the potential for enhancing glucose monitoring systems and suggest avenues for future research in diabetes management.


10 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LMLudovica La Monica
Ludovica La Monica
CCCostanza Cenerini
Costanza Cenerini
Luca VolleroLuca Vollero
Luca Vollero
Giorgio PennazzaGiorgio Pennazza
Giorgio Pennazza
Marco SantonicoMarco Santonico
Marco Santonico
FKFlavio Keller
Flavio Keller
Facial expression recognition (FER) poses a complex challenge due to diverse factors such as facial morphology variations, lighting conditions, and cultural nuances in emotion representation. To address these hurdles, specific FER algorithms leverage advanced data analysis for inferring emotional states from facial expressions. In this study, we introduce a universal validation methodology assessing any FER algorithm’s performance through a web application where subjects respond to emotive images. We present the labelled data database, FeelPix, generated from facial landmark coordinates during FER algorithm validation. FeelPix is available to train and test generic FER algorithms, accurately identifying users’ facial expressions. A testing algorithm classifies emotions based on FeelPix data, ensuring its reliability. Designed as a computationally lightweight solution, it finds applications in online systems. Our contribution improves facial expression recognition, enabling the identification and interpretation of emotions associated with facial expressions, offering profound insights into individuals’ emotional reactions. This contribution has implications for healthcare, security, human-computer interaction, and entertainment.