Some Clayey soils are generally categorized as weak soils, and structures lying on such soils have been exposed to severe damage. Therefore, the central thesis of this paper is the impact of a waste material known as a silica fume as nano and micro material on soil’s behaviour. To evaluate the effects of those additives on Atterberg limits, compaction characteristics and unconfined compressive strength, clayey soil samples have been transformed using micro and nano silica fume (by-product materials). In the current investigation, silica fume is used at four different percentages: 0, 2, 4, and 7%. The results show that the plasticity index of soil decreases with the addition of micro silica and increases with the addition of nano-silica. Increasing nano silica percentage improves the dry density of the compacted soil and reduces the optimum moisture content. An opposite behavior is observed with adding micro silica to compacted soil. Finally, 4% of silica fume is found to be the optimum dosage to improve the unconfined compressive strength of the treated soil with both additives. As a result, treating the weak clay soil with micro and/or nano-silica fume has the potential to be impactful.
1 December 2021 in Engineering and Technology Journal
Dispersive soils are characterized by three features: (1) unstable structure, (2) they are readily flocculate in water, and (3) very erodible. The use of dispersed clay soils in hydraulic structures, dams and road dams can cause serious engineering problems when this soil is not identified and used befittingly. There is a simple way to determine soil dispersion and more difficult to measure dispersion. (Atterberg’slimits) (grain size analysis), and (visible classification) are not enough to recognize between (normal clays) and (dispersive clays).ASTM tests can identify dispersive clay, these include: (double hydrometer test), (chemical tests), (Crumb test), and (Pinhole test). In this paper, the dispersed soil has been artificially prepared by adding Na2CO3 to natural clay in different proportions. The proportions are 5%, 15%, 25%, 30%, 35%, and 40% by weight. The target of this investigation is to investigate the effect of degree of dispersion of the soil on Atterberg limits. The study showed that the percentage of dispersion increases with Atterberg’slimits and the dispersion ratio and the plasticity index relationship are related by a direct relationship.
Different degrees of soil contamination have been generated by oil spills and leaks from storage tanks in refineries and processing facilities, as well as by the on-and-off loading of oil in different depots. In addition to the careless disposal of spent goods (engine oil) on the ground, this also causes environmental degradation of the soil. In the present study, the effect of contamination of sandy soil by gasoline under circular footing was studied. The circular footing is supported by sandy soil that has been polluted with gasoline by mixing the sand with different percent by dry weight with gasoline (10, 15, and 20%). The contaminated soil is extended to a depth of D/2 and D (where D is the footing diameter). The findings revealed that if the underlying sand is polluted with gasoline, the carrying capacity of the foundation reduces notably. The decline in bearing capacity was found to be 65.6, 59.4, and 51.3% for the sand’s percentages of contamination (10, 15, and 20%), respectively, at the depth of contamination D/2. The reduction in carrying capacity had been discovered to be 70, 78.7, and 33.1% for the depth of contamination D and for the percentages of contamination in the used sand 10, 15, and 20%. respectively. When the depth of contamination is raised from D/2 to D, the carrying capacity decreases by roughly 5–20% for the same percentage of pollution.
When Rankine or Coulomb theories are used to design a retaining wall, it is accepted that the retaining wall will experience a lateral displacement. By allowing the wall to move laterally, the earth pressure decreases on the active side of the wall and wall and earth pressure increases on the passive side, and therefore, more economical walls can be obtained when the lateral displacement is allowed. This lateral displacement is usually not calculated when designing a retaining wall. An experimental investigation is carried out to study the lateral displacement of a retaining wall subjected to dynamic loads with different load amplitude vibration, absolute frequencies, backfill sand relative densities, and different distances between the retaining wall and the loading source. The objectives of this study are to trace the lateral displacement of retaining wall under dynamic loads other than earthquakes such as the traffic load caused by trucks or railroads by direct measurement of displacements. The model footing used in this study is square. On a cohesionless soil, the tests were carried out using a dynamic load. The studied variables were as follows: three load amplitudes (0.25, 0.5, and 1 ton), three vibration frequencies (0.5, 1, and 2 Hz), two relative densities of sandy soil (30% loose sand and 70% dense sand), and three different distances between the foundation and the retaining wall. Observations show that the lateral displacement increased by increasing the load amplitude and decreased by increasing the distance between the foundation and the retaining wall. There is insignificant consequence of frequency on the cumulative lateral displacement. The lateral displacement decreased by increasing the density of sandy soil.