This paper presents the detection of High Impedance Fault (HIF) in solar Photovoltaic (PV) integrated power system using recurrent neural network-based Long Short-Term Memory (LSTM) approach. For study this, an IEEE 13-bus system was modeled in MATLAB/Simulink environment to integrate 300 kW solar PV systems for analysis. Initially, the three-phase current signal during non-faulty (regular operation, capacitor switching, load switching, transformer inrush current) and faulty (HIF, symmetrical and unsymmetrical fault) conditions were used for extraction of features. The signal processing technique of Discrete Wavelet Transform with db4 mother wavelet was applied to extract each phase's energy value features for training and testing the classifiers. The proposed LSTM classifier gives the overall classification accuracy of 91.21% with a success rate of 92.42 % in identifying HIF in PV integrated power network. The prediction results obtained from the proffered method are compared with other well-known classifiers of K-Nearest neighbor's network, Support vector machine, J48 based decision tree, and Naïve Bayes approach. Further, the classifier's robustness is validated by evaluating the performance indices (PI) of kappa statistic, precision, recall, and F-measure. The results obtained reveal that the proposed LSTM network significantly outperforms all PI compared to other techniques.
This paper presents application of a new effective metaheuristic optimization method namely, the Jaya algorithm to deal with different optimum power flow (OPF) problems. Unlike other population-based optimization methods, no algorithm-particular controlling parameters are required for this algorithm. In this work, three goal functions are considered for the OPF solution: generation cost minimization, real power loss reduction, and voltage stability improvement. In addition, the effect of distributed generation (DG) is incorporated into the OPF problem using a modified formulation. For best allocation of DG unit(s), a sensitivity-based procedure is introduced. Simulations are carried out on the modified IEEE 30-bus and IEEE 118-bus networks to determine the effectiveness of the Jaya algorithm. The single objective optimization cases are performed both with and without DG. For all considered cases, results demonstrate that Jaya algorithm can produce an optimum solution with rapid convergence. Statistical analysis is also carried out to check the reliability of the Jaya algorithm. The optimal solution obtained by the Jaya algorithm is compared with different stochastic algorithms, and demonstrably outperforms them in terms of solution optimality and solution feasibility, proving its effectiveness and potential. Notably, optimal placement of DGs results in even better solutions.
With the modernization of power grids, the network optimal utilization is essential to ensure that voltage profile at each bus is maintained within an acceptable range, voltage stability of the system is enhanced, power losses in lines are minimized, reliability and security of system are improved and etc. These can be achieved by introducing reactive power compensation devices such as Flexible Alternating Current Transmission System (FACTS) devices, Custom Power (CP) devices, synchronous condenser, capacitor bank and etc in distribution or transmission networks. Optimal location and sizing of the reactive power compensation devices are significantly important to ensure sufficient investment onto this device. Recently, most of conducted studies had focused on the techniques for determining the optimal location and sizing of various reactive power compensation devices in the power system using various indices proposed in the literature to access the power loss, voltage stability, voltage profile and line loadability. However, no review paper had discussed on the application of the existing indices adopted in the available techniques for solving the optimal location and sizing problems for all types of reactive power compensation devices. In this paper, current literature survey on optimal location and sizing of reactive power compensations had been discussed which includes analytical, conventional, metaheuristic and hybrid based approaches. The main objectives are to reduce power losses, to mitigate voltage deviations, to increase voltage stability and to improve reliability and security of the system.
This paper presents the automatic load frequency control (ALFC) of two-area multisource hybrid power system (HPS). The interconnected HPS model consists of conventional and renewable energy sources operating in disparate combinations to balance the generation and load demand of the system. In the proffered work, the stability analysis of nonlinear dynamic HPS model was analyzed using the Hankel method of model order reduction. Also, an attempt was made to apply cascade proportional integral – proportional derivative (PI-PD) control for HPS. The gains of the controller were optimized by minimizing the integral absolute error (IAE) of area control error using particle swarm optimization–gravitational search algorithm (PSO-GSA) optimization technique. The performance of cascade control was compared with other classical controllers and the efficiency of this approach was studied for various cases of HPS model. The result shows that the cascade control produced better transient and steady state performances than those of the other classical controllers. The robustness analysis also reveals that the system overshoots/undershoots in frequency response pertaining to random change in wind power generation and load perturbations were significantly reduced by the proposed cascade control. In addition, the sensitivity analysis of the system was performed, with the variation in step load perturbation (SLP) of 1% to 5%, system loading and inertia of the system by ±25% of nominal values to prove the efficiency of the controller. Furthermore, to prove the efficiency of PSO-GSA tuned cascade control, the results were compared with other artificial intelligence (AI) methods presented in the literature. Further, the stability of the system was analyzed in frequency domain for different operating cases.
Microgrids, comprising distributed generation, energy storage systems, and loads, have recently piqued users’ interest as a potentially viable renewable energy solution for combating climate change. According to the upstream electricity grid conditions, microgrid can operate in grid-connected and islanded modes. Energy storage systems play a critical role in maintaining the frequency and voltage stability of an islanded microgrid. As a result, several energy management systems techniques have been proposed. This paper introduces a microgrid system, an overview of local control in a microgrid, and an efficient EMS for effective microgrid operations using three smart controllers for optimal microgrid stability. We designed a microgrid consisting of renewable sources, Li-ion batteries, the main grid as a backup system, and AC/DC loads. The proposed system control was based on supplying loads as efficiently as possible using renewable energy sources and monitoring the battery’s state of charge. The simulation results using MATLAB Simulink demonstrate the performance of the three proposed microgrid stability strategies (PID, artificial neural network, and fuzzy logic). The comparison results confirmed the viability and effectiveness of the proposed technique for energy management in a microgrid which is based on fuzzy logic controllers.