Piero Giorgio Fallica

Dr. Piero Giorgio Fallica


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Daniela CardoneDaniela Cardone
Daniela Cardone
David PerpetuiniDavid Perpetuini
David Perpetuini
CFChiara Filippini
Chiara Filippini
LMLorenza Mancini
Lorenza Mancini
SNSergio Nocco
Sergio Nocco
Arcangelo MerlaArcangelo Merla
Arcangelo Merla
Mental workload (MW) represents the amount of brain resources required to perform concurrent tasks. The evaluation of MW is of paramount importance for Advanced Driver-Assistance Systems, given its correlation with traffic accidents risk. In the present research, two cognitive tests (Digit Span Test—DST and Ray Auditory Verbal Learning Test—RAVLT) were administered to participants while driving in a simulated environment. The tests were chosen to investigate the drivers’ response to predefined levels of cognitive load to categorize the classes of MW. Infrared (IR) thermal imaging concurrently with heart rate variability (HRV) were used to obtain features related to the psychophysiology of the subjects, in order to feed machine learning (ML) classifiers. Six categories of models have been compared basing on unimodal IR/unimodal HRV/multimodal IR + HRV features. The best classifier performances were reached by the multimodal IR + HRV features-based classifiers (DST: accuracy = 73.1%, sensitivity = 0.71, specificity = 0.69; RAVLT: accuracy = 75.0%, average sensitivity = 0.75, average specificity = 0.87). The unimodal IR features based classifiers revealed high performances as well (DST: accuracy = 73.1%, sensitivity = 0.73, specificity = 0.73; RAVLT: accuracy = 71.1%, average sensitivity = 0.71, average specificity = 0.85). These results demonstrated the possibility to assess drivers’ MW levels with high accuracy, also using a completely non-contact and non-invasive technique alone, representing a key advancement with respect to the state of the art in traffic accident prevention.

16 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Antonio Maria  ChiarelliAntonio Maria Chiarelli
Antonio Maria Chiarelli
David PerpetuiniDavid Perpetuini
David Perpetuini
Pierpaolo CrocePierpaolo Croce
Pierpaolo Croce
GGGiuseppe Greco
Giuseppe Greco
LMLeonardo Mistretta
Leonardo Mistretta
Giuseppe GiaconiaGiuseppe Giaconia
Giuseppe Giaconia
Portable neuroimaging technologies can be employed for long-term monitoring of neurophysiological and neuropathological states. Functional Near-Infrared Spectroscopy (fNIRS) and Electroencephalography (EEG) are highly suited for such a purpose. Their multimodal integration allows the evaluation of hemodynamic and electrical brain activity together with neurovascular coupling. An innovative fNIRS-EEG system is here presented. The system integrated a novel continuous-wave fNIRS component and a modified commercial EEG device. fNIRS probing relied on fiberless technology based on light emitting diodes and silicon photomultipliers (SiPMs). SiPMs are sensitive semiconductor detectors, whose large detection area maximizes photon harvesting from the scalp and overcomes limitations of fiberless technology. To optimize the signal-to-noise ratio and avoid fNIRS-EEG interference, a digital lock-in was implemented for fNIRS signal acquisition. A benchtop characterization of the fNIRS component showed its high performances with a noise equivalent power below 1 pW. Moreover, the fNIRS-EEG device was tested in vivo during tasks stimulating visual, motor and pre-frontal cortices. Finally, the capabilities to perform ecological recordings were assessed in clinical settings on one Alzheimer’s Disease patient during long-lasting cognitive tests. The system can pave the way to portable technologies for accurate evaluation of multimodal brain activity, allowing their extensive employment in ecological environments and clinical practice.

30 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SRSergio Rinella
Sergio Rinella
Simona MassiminoSimona Massimino
Simona Massimino
PFPiero Giorgio Fallica
Piero Giorgio Fallica
AGAlberto Giacobbe
Alberto Giacobbe
Nicola DonatoNicola Donato
Nicola Donato
SCSabrina Conoci
Sabrina Conoci
Automatically recognizing negative emotions, such as anger or stress, and also positive ones, such as euphoria, can contribute to improving well-being. In real-life, emotion recognition is a difficult task since many of the technologies used for this purpose in both laboratory and clinic environments, such as electroencephalography (EEG) and electrocardiography (ECG), cannot realistically be used. Photoplethysmography (PPG) is a non-invasive technology that can be easily integrated into wearable sensors. This paper focuses on the comparison between PPG and ECG concerning their efficacy in detecting the psychophysical and affective states of the subjects. It has been confirmed that the levels of accuracy in the recognition of affective variables obtained by PPG technology are comparable to those achievable with the more traditional ECG technology. Moreover, the affective psychological condition of the participants (anxiety and mood levels) may influence the psychophysiological responses recorded during the experimental tests.

21 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
David PerpetuiniDavid Perpetuini
David Perpetuini
Antonio Maria  ChiarelliAntonio Maria Chiarelli
Antonio Maria Chiarelli
Daniela CardoneDaniela Cardone
Daniela Cardone
SRSergio Rinella
Sergio Rinella
Simona MassiminoSimona Massimino
Simona Massimino
Arcangelo MerlaArcangelo Merla
Arcangelo Merla
Cardiovascular disease is a leading cause of death. Several markers have been proposed to predict cardiovascular morbidity. The ankle-brachial index (ABI) marker is defined as the ratio between the ankle and the arm systolic blood pressures, and it is generally assessed through sphygmomanometers. An alternative tool for cardiovascular status assessment is Photoplethysmography (PPG). PPG is a non-invasive optical technique that measures volumetric blood changes induced by pulse pressure propagation within arteries. However, PPG does not provide absolute pressure estimation, making assessment of cardiovascular status less direct. The capability of a multivariate data-driven approach to predict ABI from peculiar PPG features was investigated here. ABI was measured using a commercial instrument (Enverdis Vascular Explorer, VE-ABI), and it was then used for a General Linear Model estimation of ABI from multi-site PPG in a supervised learning framework (PPG-ABI). A Receiver Operating Characteristic (ROC) analysis allowed to investigate the capability of PPG-ABI to discriminate cardiovascular impairment as defined by VE-ABI. Findings suggested that ABI can be estimated form PPG (r = 0.79) and can identify pathological cardiovascular status (AUC = 0.85). The advantages of PPG are simplicity, speed and operator-independency, allowing extensive screening of cardiovascular status and associated cardiovascular risks.

17 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
David PerpetuiniDavid Perpetuini
David Perpetuini
Antonio Maria  ChiarelliAntonio Maria Chiarelli
Antonio Maria Chiarelli
LMLidia Maddiona
Lidia Maddiona
SRSergio Rinella
Sergio Rinella
Francesco BiancoFrancesco Bianco
Francesco Bianco
PFPiero Giorgio Fallica
Piero Giorgio Fallica
The development and validation of a system for multi-site photoplethysmography (PPG) and electrocardiography (ECG) is presented. The system could acquire signals from 8 PPG probes and 10 ECG leads. Each PPG probe was constituted of a light-emitting diode (LED) source at a wavelength of 940 nm and a silicon photomultiplier (SiPM) detector, located in a back-reflection recording configuration. In order to ensure proper optode-to-skin coupling, the probe was equipped with insufflating cuffs. The high number of PPG probes allowed us to simultaneously acquire signals from multiple body locations. The ECG provided a reference for single-pulse PPG evaluation and averaging, allowing the extraction of indices of cardiovascular status with a high signal-to-noise ratio. Firstly, the system was characterized on optical phantoms. Furthermore, in vivo validation was performed by estimating the brachial-ankle pulse wave velocity (baPWV), a metric associated with cardiovascular status. The validation was performed on healthy volunteers to assess the baPWV intra- and extra-operator repeatability and its association with age. Finally, the baPWV, evaluated via the developed instrumentation, was compared to that estimated with a commercial system used in clinical practice (Enverdis Vascular Explorer). The validation demonstrated the system’s reliability and its effectiveness in assessing the cardiovascular status in arterial ageing.

5 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GMGiovanni Maira
Giovanni Maira
Antonio Maria  ChiarelliAntonio Maria Chiarelli
Antonio Maria Chiarelli
SBStefano Brafa
Stefano Brafa
Sebania LibertinoSebania Libertino
Sebania Libertino
PFPiero Giorgio Fallica
Piero Giorgio Fallica
Salvatore Antonino LombardoSalvatore Antonino Lombardo
Salvatore Antonino Lombardo
We built a fiber-less prototype of an optical system with 156 channels each one consisting of an optode made of a silicon photomultiplier (SiPM) and a pair of light emitting diodes (LEDs) operating at 700 nm and 830 nm. The system uses functional near-infrared spectroscopy (fNIRS) and diffuse optical tomography (DOT) imaging of the cortical activity of the human brain at frequencies above 1 Hz. In this paper, we discuss testing and system optimization performed through measurements on a multi-layered optical phantom with mechanically movable parts that simulate near-infrared light scattering inhomogeneities. The baseline optical characteristics of the phantom are carefully characterized and compared to those of human tissues. Here we discuss several technical aspects of the system development, such as LED light output drift and its possible compensation, SiPM linearity, corrections of channel signal differences, and signal-to-noise ratio (SNR). We implement an imaging algorithm that investigates large phantom regions. Thanks to the use of SiPMs, very large source-to-detector distances are acquired with a high SNR and 2 Hz time resolution. The overall results demonstrate the high potentialities of a system based on SiPMs for fNIRS/DOT human brain imaging applications.