Ana María Cao-Paz

Dr. Ana María Cao-Paz

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2010 in Sensors
Verified
Journal Article
Open access
PDF file
ACAna María Cao-Paz
Ana María Cao-Paz
JAJorge Marcos Acevedo
Jorge Marcos Acevedo
ARAlfredo Del Río-Vázquez
Alfredo Del Río-Vázquez
CMCarlos Martínez-Peñalver
Carlos Martínez-Peñalver
AFAlfonso Lago Ferreiro
Alfonso Lago Ferreiro
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
This article describes a multi-point optical fiber-based sensor for the measurement of electrolyte density in lead-acid batteries. It is known that the battery charging process creates stratification, due to the different densities of sulphuric acid and water. In order to study this process, density measurements should be obtained at different depths. The sensor we describe in this paper, unlike traditional sensors, consists of several measurement points, allowing density measurements at different depths inside the battery. The obtained set of measurements helps in determining the charge (SoC) and state of health (SoH) of the battery.

3 August 2012 in Sensors
Verified
Journal Article
Open access
PDF file
ACAna María Cao-Paz
Ana María Cao-Paz
LRLoreto Rodriguez-Pardo
Loreto Rodriguez-Pardo
JFJosé Fariña
José Fariña
JAJorge Marcos Acevedo
Jorge Marcos Acevedo
In battery applications, particularly in automobiles, submarines and remote communications, the state of charge (SoC) is needed in order to manage batteries efficiently. The most widely used physical parameter for this is electrolyte density. However, there is greater dependency between electrolyte viscosity and SoC than that seen for density and SoC. This paper presents a Quartz Crystal Microbalance (QCM) sensor for electrolyte density-viscosity product measurements in lead acid batteries. The sensor is calibrated in H2SO4 solutions in the battery electrolyte range to obtain sensitivity, noise and resolution. Also, real-time tests of charge and discharge are conducted placing the quartz crystal inside the battery. At the same time, the present theoretical “resolution limit” to measure the square root of the density-viscosity product ( ) of a liquid medium or best resolution achievable with a QCM oscillator is determined. Findings show that the resolution limit only depends on the characteristics of the liquid to be studied and not on frequency. The QCM resolution limit for measurements worsens when the density-viscosity product of the liquid is increased, but it cannot be improved by elevating the work frequency.

1 November 2006
Verified
Conference Paper
Closed access
ACAna María Cao-Paz
Ana María Cao-Paz
JAJorge Marcos Acevedo
Jorge Marcos Acevedo
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
AVAlfredo del Rio Vazquez
Alfredo del Rio Vazquez
In order to manage batteries efficiently, it is necessary to know its state of charge. One of the physical parameters with information about the state of charge is the electrolyte density. This paper presents a plastic optic fibre sensor developed for measuring in real time the electrolyte density in lead-acid batteries. The multisensor consists of several optic fibre placed inside the battery at different positions in order to make measures at different heights. An electronic circuit was designed for controlling the light emitters and detectors in order to minimize the effects of the ambient light and temperature

7 July 2021
Verified
Conference Paper
Closed access
JCJ. Costas Costas
J. Costas Costas
LRLoreto Rodriguez-Pardo
Loreto Rodriguez-Pardo
ACAna María Cao-Paz
Ana María Cao-Paz
JFJ. Fariña
J. Fariña
HPHubert Perrot
Hubert Perrot
DRD. Rose
D. Rose
In this work a QCM sensor system based on the phase shift detection method is implemented. The system is characterized for liquid measurement applications. The experimental calibration of the sensor system is performed with solutions of increasing viscosities, obtaining the equation of the sensitivity of the output voltage to the changes in the square root of the density-viscosity product of the liquid.

9 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CGCamilo Quintans Grana
Camilo Quintans Grana
MPMaría Dolores Valdes Valdés Peña
María Dolores Valdes Valdés Peña
ACAna María Cao-Paz
Ana María Cao-Paz
MRMaria Jose Moure Rodriguez
Maria Jose Moure Rodriguez
JAJorge Marcos Acevedo
Jorge Marcos Acevedo
In measurement systems, it is essential to have a procedure to obtain not only the calibration curve but also its associated uncertainty for the entire operating range. To achieve it, different alternatives should be taken into account according to the characteristics of the measurement, the way they are taken, the repeatability and reproducibility of the experiments or the nature of the measurement itself. This work presents a step-by-step procedure, to obtain simultaneously the calibration and uncertainty curves of a measurement system, which takes advantage of the maximum likelihood estimation (MLE), the weighted least squares (WLS) method, and the ISO-28037 recommendations. As an application, a U-Bent plastic optical fiber (POF) sensor measuring the sucrose solution density related to the refractive index (RI) is implemented and calibrated according to the proposed procedure.