Modeling IT equipment is of critical importance for the simulations of flow and thermal structures in air cooled data centers. Turbulent flow undergoes a significant pressure drop through the server due to the energy losses originating from the internal components. Therefore, there is an urgent need to develop a fast and an accurate method for the calculation of pressure losses inside server components for data center applications. In this study, high resolution numerical simulations were performed on an OCP (Open Compute Project) server under various inlet flow rates for inactive and active conditions. Meanwhile, one key challenge of modeling complete geometry of the server results from using an intense mesh even for a single server. To address this challenge, the server was modeled as a porous zone to mimic inertia and viscous resistance in a realistic way. Comparison of the results of porous and complete models showed that the proposed model could calculate pressure drop accurately even when the number of cells in the server was reduced to 0.3% of the complete model. Porosity coefficients were determined from the numerical simulations conducted in a broad range of air discharge for both active and inactive conditions. Errors in the calculation of pressure drop may result in a significant deviation in the prediction of the temperature rise over the server. Thus, the present model can effectively be used for the fast and accurate prediction of pressure drop inside a server component rather than solving internal flow on an intense mesh, while simulating airflow inside an air-cooled data center, which is crucial for the design safety of data centers. Finally, calculated porosity coefficients can be used for the prediction of the pressure drop in a server, while designing data centers based on numerical simulations.
In this study, an open-source computational fluid dynamics (CFD) model was developed based on OpenFOAM libraries for the accurate and robust simulation of thermal distribution in a data center. Two boundary conditions were developed for the temperature field in the black-box modeling of server components. The numerical model was first validated by comparing numerical results with the experimental measurements for three benchmark problems in the field of thermal engineering. Then, thermal distribution in an open-aisle data center was simulated using the proposed numerical model and results were compared with the experimental measurements. The consistency between numerical results and previous experimental measurements indicates that the present numerical model can be reliably used for the efficiency assessment of air-cooled data centers. Efficiency of the data center can be evaluated with respect to four metrics in the proposed numerical model. In addition to the determination of the overall efficiency, distribution of the efficiency can be monitored over the racks to capture thermal zones where the efficiency decreases due to the recirculation effects and cold air by-pass.
The new reporting scheme adopted by the European Union focuses on the efficiency assessment of data centers based on key performance indicators (KPIs). This has the potential to lead to further measures for improving energy efficiency of data centers. Consequently, a systematic approach is crucial for assessing and improving data center performance. This study investigates efficiency assessment of two European pilot data centers, located in Denmark and Poland, according to the KPIs calculated through Computational Fluid Dynamics (CFD) simulations of airflow and thermal structures. Two separate experimental approaches were adopted at the pilot sites. One measured airflow and temperatures using external sensors at server inlets and outlets, while the other measured inlet temperatures from embedded server sensors. The good agreement observed between simulated and experimental data confirmed the accuracy of the computational model. The validated CFD model was applied to investigate efficiency improvement opportunities by retrofitting the thermal environment such as rack positioning, containment implementation, and guided airflow control. A series of numerical simulations are performed using the validated numerical model and KPIs are calculated for each design. Numerical simulations demonstrate that the efficiency of an existing data center can be enhanced by up to 75% using the presented approach, although the improvement varied significantly with the specific KPIs. The computational approach proposed here can be readily generalized to guide the efficiency assessment and improvement of existing data centers.
Evapotranspiration (ET), which is a combination of the words evaporation and transpiration, is expressed as the sum of water due to water consumption and evaporation in plants. In this study, the NASA Drought Early Warning Systems Network Land Data Assimilation System model (FLDAS NOAH) was used to determine evapotranspiration data for the 2018-2019 water years (October 2017-September 2019) on Turkey. In addition, NASA Global Land Data Assimilation System (GLDAS NOAH) was used for temperature data. Total precipitation data with corrected error rates are taken from MERRA-2 Model M2TMNXFLX. The relationship between the determined monthly total average evapotranspiration values and the monthly average precipitation and monthly average temperature values was determined by ArcGIS. It is important to examine the local evaporation and transpiration conditions in more detail in the regions where water resources planning will be made. The importance of water holding capacity in plants in determining agricultural and hydrological drought can be explained by evapotranspiration.
Liquid-cooled servers can be deployed to reduce the energy consumption and environmental footprint of hybrid-cooled data centers. A computational fluid dynamics (CFD) model can bring extremely useful insights and results for thermal simulations of air- and liquid-cooled servers in a single environment. In this study, a conjugate heat transfer (CHT) numerical model is developed and validated with experimental data to simulate heat transfer from the CPU to the air and cold plate considering the effect of thermal paste. The cooling performance of an in-house developed cold plate design is thoroughly investigated via the validated CHT model. A dataset containing one hundred samples of various flow, thermal and workload conditions was generated using the Latin hypercube sampling (LHS) method, which was further utilized in the series of CHT simulations. Finally, a novel empirical equation is proposed for the prediction of heat transfer from the CPU to the air. The accuracy of the proposed equation is confirmed by comparing estimated and simulated results for a test dataset. A thermal analysis of a rack containing air and liquid-cooled servers is performed using the presented approach. The simulation results reveal that the proposed compact model can be used reliably for the thermal simulation of a hybrid-cooled data center.