Çağatay Yılmaz

Mr. Çağatay Yılmaz

Lande Endüstriyel Metal Ürünler Sanayi ve Ticaret A.Ş., Eskişehir, Turkey (Türkiye)
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2022 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
Mustafa KuzayMustafa Kuzay
Mustafa Kuzay
ADAras Dogan
Aras Dogan
Sibel YılmazSibel Yılmaz
Sibel Yılmaz
OHOguzhan Herkiloglu
Oguzhan Herkiloglu
AAAli Serdar Atalay
Ali Serdar Atalay
Ender DemirelEnder Demirel
Ender Demirel

3 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
ADAras Dogan
Aras Dogan
Sibel YılmazSibel Yılmaz
Sibel Yılmaz
Mustafa KuzayMustafa Kuzay
Mustafa Kuzay
Çağatay YılmazÇağatay Yılmaz
Çağatay Yılmaz
Ender DemirelEnder Demirel
Ender Demirel
Modeling IT equipment is of critical importance for the simulations of flow and thermal structures in air cooled data centers. Turbulent flow undergoes a significant pressure drop through the server due to the energy losses originating from the internal components. Therefore, there is an urgent need to develop a fast and an accurate method for the calculation of pressure losses inside server components for data center applications. In this study, high resolution numerical simulations were performed on an OCP (Open Compute Project) server under various inlet flow rates for inactive and active conditions. Meanwhile, one key challenge of modeling complete geometry of the server results from using an intense mesh even for a single server. To address this challenge, the server was modeled as a porous zone to mimic inertia and viscous resistance in a realistic way. Comparison of the results of porous and complete models showed that the proposed model could calculate pressure drop accurately even when the number of cells in the server was reduced to 0.3% of the complete model. Porosity coefficients were determined from the numerical simulations conducted in a broad range of air discharge for both active and inactive conditions. Errors in the calculation of pressure drop may result in a significant deviation in the prediction of the temperature rise over the server. Thus, the present model can effectively be used for the fast and accurate prediction of pressure drop inside a server component rather than solving internal flow on an intense mesh, while simulating airflow inside an air-cooled data center, which is crucial for the design safety of data centers. Finally, calculated porosity coefficients can be used for the prediction of the pressure drop in a server, while designing data centers based on numerical simulations.

5 January 2026 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
VAVahid Ebrahimpour Ahmadi
Vahid Ebrahimpour Ahmadi
HBHenrik A. Barestrand
Henrik A. Barestrand
Jon SummersJon Summers
Jon Summers
Çağatay YılmazÇağatay Yılmaz
Çağatay Yılmaz

11 September 2022 in Data in Brief
Verified
Journal Article
Open access
Mustafa KuzayMustafa Kuzay
Mustafa Kuzay
ADAras Dogan
Aras Dogan
Sibel YılmazSibel Yılmaz
Sibel Yılmaz
OHOguzhan Herkiloglu
Oguzhan Herkiloglu
AAAli Serdar Atalay
Ali Serdar Atalay
Ender DemirelEnder Demirel
Ender Demirel
This article provides experimental and numerical data for the flow and thermal distributions inside an air-cooled data center. The experimental data contains the exhaust temperature profile obtained from an experimental campaign and the numerical data contains OpenFOAM and script files for the simulation of the thermal structure based on the experimental study. Experimental measurements were conducted using temperature sensors located at the rear of the rack under a working scenario of 2 kW. Publically available experimental data, numerical model and results can be used for the validation of numerical models under the thermal scenario given in the present study. Flow and thermal structures inside the data center are exhibited using the validated numerical model.


5 October 2026 in Building and Environment
Verified
Journal Article
Open access
BKBinod Prasad Koirala
Binod Prasad Koirala
GHG. Humbert
G. Humbert
HCH. Cai
H. Cai
MBM. Brandes
M. Brandes
SSS. Stoller
S. Stoller
AMA. Morotz
A. Morotz