In potable water treatment, the commonly used disinfectants are chlorine and ozone. Recently, the use of ozone has gained more acceptance due to its effective disinfectant properties. However, water treatment with ozone is more expensive because ozone production is an energy-intensive processes. Thus the mechanical mixing efficiency (passive mixing) of the contact system used in this process is critical to reduce the amount of disinfectant used to treat a fixed volume of water. Traditional contact tank designs suffer from poor mixing, short-circuiting, and high energy requirements to drive the flow through the contactor. This study introduces a patented novel baffle design to improve the efficiency of contact tanks. Computational fluid dynamics (CFD)–based analysis indicates that the proposed baffle design improves the mechanical mixing efficiency by 51% and reduces the energy required to drive the flow through the system and short-circuiting by 51 and 57%, respectively. Calculations indicate that the savings offered by this design will be on the order of several hundred thousand dollars per year for medium-sized water treatment plants. The proposed design is simple to implement without expensive infrastructure modifications, and can be used for both chlorine and ozone treatment.
A slot-baffle design used in water treatment tanks previously developed by the authors is used to suppress sloshing effects in an accelerated tank. This new application is another example of the versatility of the slot-baffle design in inducing turbulence in fluid flow systems, which has numerous uses in engineering applications. Large amplitude surface waves in a harmonically excited tank are simulated using a second-order accurate numerical model in OpenFOAM. The verification of the numerical model is performed by comparing the numerical results with existing laboratory measurements, which show a favorable agreement. Various slot configurations are studied in order to evaluate the damping performance during the external excitation of the tank. It is shown that the present design shows an effective dissipation performance in a broad range of oscillation frequencies, while 88% of the internal kinetic energy of the liquid is dissipated over thirty oscillation periods for the resonance case.
Multi-chamber contact tanks have been extensively used in industry for water treatment to provide potable water to communities, which is essential for human health. To evaluate the efficiency of this treatment process, flow and tracer transport analysis have been used in the literature using Reynolds averaged Navier–Stokes (RANS) and large-eddy simulations (LES). The purpose of this study is two-fold. First a unifying analysis of the flow field is presented and similarities and differences in the numerical results that were reported in the literature are discussed. Second, the vorticity field is identified as the key parameter to use in separating the mean flow (jet zone) and the recirculating zones. Based on the concepts of vorticity gradient and flexion product, it is demonstrated that the separation of the recirculation zone and the jet zone, fluid-fluid flow separation, is possible. The separation of the recirculation zones and vortex core lines are characterized using the definition of the Lamb vector. The separated regions are used to characterize the mixing efficiency in the chambers of the contact tank. This analysis indicates that the recirculation zone and jet zone formation are three-dimensional and require simulations over a long period of time to reach stability. It is recognized that the characteristics of the jet zones and the recirculation zones are distinct for each chamber and they follow a particular pattern and symmetry between the alternating chambers. Hydraulic efficiency coefficients calculated for each chamber show that the chambers having an inlet adjacent to the free surface may be designed to have larger volumes than the chambers having wall bounded inlets to improve the efficiency of the contact tank. This is a simple design alternative that would increase the efficiency of the system. Other observations made through the chamber analysis are also informative in redefining the characteristics of the efficiency of the contact tank system.
Three-dimensional numerical simulations are performed to evaluate the effect of porous baffles on the efficiency of water treatment contact tanks. A second-order accurate numerical model is employed for the solutions of unsteady flow and tracer transport through the porous baffles. The flow through the porous medium is characterized while using the Darcy-Forchheimer relationship. Large Eddy Simulation (LES) model is used to simulate the instantaneous mixing of the tracer in the chambers of the contact tank. Three different porosities are considered to evaluate the effect of porosity on the hydraulic and mixing efficiencies of the contact tank. Simulated time-averaged flow field shows that porous baffles that are placed at the entrance of each chamber could successfully mitigate short-circuiting and yield plug-flow conditions through the system for low porosities. Flow in the contact tank becomes laminar as the flow velocities decrease due to viscous effects and inertial resistance in the porous zone. For this case, the tracer is transported with bulk flow through the system and leaves the contact tank with a high peak seen in the Residence Time Distribution (RTD) plot. Porous layer increases the hydraulic efficiency of the conventional design from “poor” to “good” according to the baffling factor and increases the overall efficiency from “compromising” to “good” according to the AD index. Comparison of the performance of the porous layer with the previously developed slot-baffle design shows that the slot-baffle design increases the efficiency of the tank with increasing dispersion effects, whereas the porous design increases hydraulic efficiency and reduces the dispersion effects. While the porous design reduces energy efficiency by 33% due to a drastic increase in drag in the flow through porous zone, the slot-baffle design increases the energy efficiency of the conventional design by 67%.
Mixing characteristics of multi-chambered contact tank are analyzed employing the validated three-dimensional numerical model developed in the companion paper. Based on the flow characterization, novel volumetric mixing efficiency definitions are proposed for the assessment of the hydrodynamic and chemical transport properties of the contact tank and its chambers. Residence time distribution functions are analyzed not only at the outlet of each chamber but also inside the chambers using the efficiency definitions for both Reynolds averaged Navier–Stokes (RANS) and large eddy simulation (LES) results. A novel tracer mixing index is defined to characterize short circuiting and mixing effects of the contact system. Comparisons of the results of these indexes for RANS and LES solutions indicate that mixing characteristics are stronger in LES due to the unsteady turbulent eddy mixing even though short circuiting effects are also more prominent in LES results. This result indicates that the mixing analysis based on the LES results simulates the mixing characteristics instantaneously, which is more realistic than that in RANS. Since LES analysis can capture turbulent eddy mixing better than RANS analysis, the interaction of recirculation and jet zones are captured more effectively in LES, which tends to predict higher turbulent mixing in the contact system. The analysis also shows that the mixing efficiency of each chamber of the contact tank is different, thus it is necessary to consider distinct chemical release and volumetric designs for each chamber in order to maximize the mixing efficiency of the overall process in a contact tank system.