Xinpeng Yang

Mr. Xinpeng Yang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2023 in Renewable Energy
Verified
Journal Article
Closed access
XYXinpeng Yang
Xinpeng Yang
DLDong Li
Dong Li
RYRuitong Yang
Ruitong Yang
YMYuxin Ma
Yuxin Ma
YDYanjiao Duan
Yanjiao Duan
Muslum AriciMuslum Arici
Muslum Arici

26 September 2024 in Energy and Buildings
Verified
Journal Article
Closed access
DLDong Li
Dong Li
YDYanjiao Duan
Yanjiao Duan
CZChengjun Zhang
Chengjun Zhang
WHWanyu Hu
Wanyu Hu
XYXinpeng Yang
Xinpeng Yang
XWXueyang Wang
Xueyang Wang

24 November 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
LYLu Yao
Lu Yao
FAFaisal Khaled Aldawood
Faisal Khaled Aldawood
WHWanyu Hu
Wanyu Hu
YMYuxin Ma
Yuxin Ma
Mohamed KchaouMohamed Kchaou
Mohamed Kchaou
Dong LiDong Li
Dong Li
To improve the energy efficiency and photo-thermal performance of a double-layer PCM glazing window (DP), multilayer PCM glazing windows integrating DP (combination structures) with installations and low-e coating have been developed. However, the energy efficiency of a multilayer glazing window is not higher than DP in all climate zones. The selection of the appropriate optimization strategy of DP, i.e., selecting the most energy-saving multilayer glazing window, should take into account the specific climatic conditions. In this study, five PCM glazing windows (DP and four multilayer combination structures) are proposed. Physical heat transfer and mathematical models were conducted to numerically investigate the thermal and energy performance by Fluent in different climate zones in China. Evaluation indexes for different climate zones were established, and the energy-saving potential of each PCM glazing window was compared, and the resulting combination structure with the most energy-saving potential in each climate zone was regarded as the optimization strategy of DP. The results demonstrated that DP with the external silica aerogel has been identified as the optimization strategy for severe cold zones with 40.28% of energy saved, but it increases energy consumption in mild zones and hot summer and warm winter zones. DP with an external air layer and internal low-e coating is considered for the optimization strategies for cold zones, hot summer, and cold winter zones, and hot summer and warm winter zones, with energy-saving potential rates up to 40.67%, 46.42%, and 46.99% respectively. However, it increases energy consumption in mild zones and cold zones. In addition, DP is proven to possess the lowest energy consumption in mild zones.

20 June 2023 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
DGDai Geng
Dai Geng
XYXinpeng Yang
Xinpeng Yang
DLDong Li
Dong Li
RYRuiTong Yang
RuiTong Yang
YMYuxin Ma
Yuxin Ma
CLChangyu Liu
Changyu Liu

20 June 2023
Verified
Conference Paper
Closed access
WHWanyu Hu
Wanyu Hu
YLYao Lu
Yao Lu
Dong LiDong Li
Dong Li
YMYuxin Ma
Yuxin Ma
XYXinpeng Yang
Xinpeng Yang
CZChengjun Zhang
Chengjun Zhang
With the improvement progress of glazing envelopes energy-saving technology, enhancing the thermal inertia of the glazing envelope by heat storage means is springing up. In this study, the heat transfer and day-lighting models of a building with PCM glazing curtain wall (PGC) were developed to analyze its indoor thermal environment and day-lighting performance. Buildings containing silica aerogel (SGC) and hollow glazing curtains (HGC) were selected as the reference models, and several indexes including inner surface temperature of glazing envelope, liquid fraction rate of PCM, indoor temperature, indoor natural illumination and indoor day-lighting coefficient were adopted as the evaluations. The results show that in comparison with SGC and HGC, the building containing PGC can greatly improve indoor temperature uniformity and indoor thermal comfort. PGC filled with 10mm PCM reduces the temperature fluctuation of the inner surface of the glass and interior midpoint temperature by 35% and delay the peak time of glass inner surface temperature by 0.89h, which significantly improves the indoor temperature uniformity and meets the natural lighting requirements. With the increase of PCM thickness, the liquid fraction rate of PCM decreases greatly, which directly degrades the energy storage performance of PGC.

26 December 2022 in Processes
Verified
Journal Article
Open access
PDF file
Dong LiDong Li
Dong Li
XYXinpeng Yang
Xinpeng Yang
XZXuefeng Zhao
Xuefeng Zhao
RYRuitong Yang
Ruitong Yang
LMLan Meng
Lan Meng
SFShaojie Fu
Shaojie Fu
The base of solar collector systems is usually installed in soil that contains moisture. In cold regions, due to the low ambient temperature, the moisture in the soil freezes, creating a risk of frost heave. This study analyzed the frost heave mechanism of power transmission and transformation foundation, clarified the factors affecting soil frost heave and the way to solve soil layer frost heave, and proposed the use of heat transfer elements to pre-frozen soil layers to prevent the foundation of the solar collector system from freezing. A numerical model of the ground heat exchange pipes in soil was established. The effects of different soil types, soil moisture content, and the effective radius and operating time on the heat transfer performance of the system were investigated by the verified numerical model. The results show that the heat pipe pre-freezing technology can reduce the drop in soil temperature, thereby increasing the temperature difference between the ground heat exchange pipe and the far-field soil. In terms of the ability to delay the decline in soil temperature, reducing the water content and selecting certain clays can increase the degree and speed of the drop in soil temperature.