Yeguang Yan

Yeguang Yan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2020 in Physical Review A
Verified
Journal Article
Closed access
PDF file
JWJing Wang
Jing Wang
WFWenfeng Fan
Wenfeng Fan
KYKaifeng Yin
Kaifeng Yin
YYYeguang Yan
Yeguang Yan
ZBZhou Binquan
Zhou Binquan
Xinda SongXinda Song
Xinda Song
This paper investigates the performance optimization of optically pumped magnetometers under zero-field parametric modulation. Based on the analytical solutions of the Bloch equation, both longitudinal and transverse modulations are studied experimentally. To estimate the nonuniform polarization distribution of alkali-metal atoms in the vapor cell, an average pumping rate model is proposed. Furthermore, the accuracy of this model and the measurement of the transverse relaxation rate are verified via the agreement between experimental and theoretical values. The results indicate that optimal performance can be achieved by employing a suitable modulation field, the selection of which is related to the modulation index u in the Bessel series and the pump-light intensity. Although both operating modes show similar responses to weak magnetic fields, their effects on pump-light intensity are different due to the means of detecting atomic polarization. An optimal value of the pump-light intensity on the response strength exists in longitudinal modulation. However, with regard to transverse modulation, the sensitivity under weak pump-light intensity is better. This research has far-reaching significance for cases when the parametric modulation is manipulated.

31 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShaowen Zhang
Shaowen Zhang
Jixi LuJixi Lu
Jixi Lu
MYMao Ye
Mao Ye
YZYing Zhou
Ying Zhou
KYKaifeng Yin
Kaifeng Yin
YZYueyang Zhai
Yueyang Zhai
In recent years, significant developments have occurred in the field of optically pumped magnetometers (OPMs), which are widely used in biomagnetic measurements. In this study, we propose a temperature optimization model for a single-beam miniaturized atomic magnetometer. Based on this model, we find that there is an optimal operating temperature for each individual vapor cell, under which the OPM achieves optimal performance. We construct a single-beam zero-field modulation OPM to prove this model. The sensitivity of the magnetometer reaches 18 fT/Hz 1/2 (close to the theoretical sensitivity) when we adjust the temperature of the vapor cell through our model, and a detection bandwidth of more than 160 Hz is achieved. It is also discovered that the system bandwidth is reduced when the temperature is increased, whereas the sensitivity of the system does not show notable variation during this process. Our model enables a quick definition of the best working temperature for each individual magnetometer, ensuring the best performance at the lowest operating temperature. This model is especially advantageous for miniaturized OPMs and can also be further applied to arrayed integration for biomagnetic measurement in the future work.

25 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FLFei Lu
Fei Lu
Jixi LuJixi Lu
Jixi Lu
Bo LiBo Li
Bo Li
YYYeguang Yan
Yeguang Yan
SZShaowen Zhang
Shaowen Zhang
BHBangcheng Han
Bangcheng Han
Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. The y -axis magnetic field measurement was realized in zero field, whereas the x - and z - axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz ( x - axis), 10.5 Hz ( y -axis), and 10.9 Hz ( z -axis) are achieved under bias magnetic fields of $B_{z-\mathrm {offset}}= 8$ nT and $B_{x-\mathrm {offset}} = 2$ nT. The bandwidth along x - axis was extended to 232 Hz under $B_{z-\mathrm {offset}} = 32$ nT, which can further be improved by increasing $B_{z-\mathrm {offset}}$ . The linear interval of measurable magnetic field are between −11.7 to +11.7 nT ( x - axis), −0.8 to +0.8 nT ( y -axis), and −28.2 to +28.2 nT ( z -axis). For x - and z -axes, the measurable interval can further be improved by increasing $B_{z-\mathrm {offset}}$ and $B_{x-\mathrm {offset}}$ , respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz 1/2 ( x - axis), 2.0 ± 0.1 fT/Hz 1/2 ( y - axis), and 6.0 ± 0.5 fT/Hz 1/2 ( z - axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.

16 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KWKun Wang
Kun Wang
Jixi LuJixi Lu
Jixi Lu
YYYeguang Yan
Yeguang Yan
JTJunjian Tang
Junjian Tang
MYMao Ye
Mao Ye
BHBangcheng Han
Bangcheng Han
Atomic magnetometers are widely acknowledged as one of the most sensitive devices for magnetic field measurement. Our study presents a novel method that enables bandwidth expansion of single-beam magnetometers in the spin-exchange relaxation-free regime. This method bases on increasing the modulation amplitude of magnetic field combining with negative feedback with proportional gain. Through our method, the magnetometer’s total relaxation rate is moderately increased by elevating modulation amplitude and frequency, and correspondingly, the detection bandwidth experiences dramatic improvement from 230 Hz to 1380 Hz. The application of negative feedback with proportional gain further increases this bandwidth to higher than 4 kHz, which is over 17 times of its original value. The sensitivity of the magnetometer under this condition is measured as 25 fT/ $\text {Hz}^{\text {1/2}}$ for open-loop scheme and 35 fT/ $\text {Hz}^{\text {1/2}}$ for closed-loop scheme. Comparatively, the sensitivity measured on conventional conditions in our experiment is 12 fT/ $\text {Hz}^{\text {1/2}}$ . This approach offers a profitable trade-off that extraordinary expansion of detection bandwidth can be acquired with the price of a little sensitivity loss. Our method is advantageous for miniaturization of atomic magnetometers as no extra hardware is added, which is of special interest for applications including biomagnetic measurement where large detection bandwidth is sometimes in need.

30 November 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KYKaifeng Yin
Kaifeng Yin
ZBZhou Binquan
Zhou Binquan
Jixi LuJixi Lu
Jixi Lu
FLFei Lu
Fei Lu
SZShaowen Zhang
Shaowen Zhang
MYMao Ye
Mao Ye
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

14 September 2022 in Photonics
Verified
Journal Article
Open access
PDF file
YYYeguang Yan
Yeguang Yan
Jixi LuJixi Lu
Jixi Lu
ZBZhou Binquan
Zhou Binquan
KWKun Wang
Kun Wang
ZLZiao Liu
Ziao Liu
GLGang Liu
Gang Liu
Three-axis atomic magnetometers have an excellent advantage for determining the complete vector information of a magnetic field to be measured. However, the crosstalk effect, which leads to an error output on one axis owing to a magnetic field on the other axes, can reduce the measurement accuracy. In this study, we propose an effective suppression method for the crosstalk effect in a three-axis atomic magnetometer. First, we investigated and analyzed the main factors that introduce the effect. Based on this, the modulation parameters were optimized to improve the scale factors, which obtained a coupling coefficient of less than 6% for the atomic magnetometer. Subsequently, the associated transfer matrix was corrected to further suppress the crosstalk effect. After correction, all the coupling coefficients were decreased to less than 3%, with the majority being lower than 1%.