Kasper Górny

Dr. Kasper Górny

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in International Journal of Refrigeration
Verified
Journal Article
Closed access
KGKasper Górny
Kasper Górny
Arkadiusz StachowiakArkadiusz Stachowiak
Arkadiusz Stachowiak
PTPrzemysław Tyczewski
Przemysław Tyczewski
WZWiesław Zwierzycki
Wiesław Zwierzycki

1 June 2019 in Tribology International
Verified
Journal Article
Closed access
KGKasper Górny
Kasper Górny
Arkadiusz StachowiakArkadiusz Stachowiak
Arkadiusz Stachowiak
PTPrzemysław Tyczewski
Przemysław Tyczewski
WZWiesław Zwierzycki
Wiesław Zwierzycki

3 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
KGKasper Górny
Kasper Górny
Arkadiusz StachowiakArkadiusz Stachowiak
Arkadiusz Stachowiak
TPTyczewski Przemysław
Tyczewski Przemysław
WZWiesław Zwierzycki
Wiesław Zwierzycki
The presented results show that the presence of refrigerant significantly deteriorates the lubricating properties of compressor oil under starved lubrication conditions (with a small amount of oil). The change can be 40–120% compared to the properties of the oil alone. Additionally, in the group of oils that are substitutes (operational alternatives) compatible with a given refrigerant, the effect of the refrigerant on the lubricating properties varies. The differences can be as much as 25%. In order to evaluate and properly select compressor oils for the refrigerant, the lubricating properties should be tested in a mixture with the refrigerant under conditions similar to actual operation. Such an evaluation of lubricating properties is made possible by the author’s method of testing the wear of the block-on-ring friction node. The obtained rankings of lubricating properties for oils (due to the wear volume) can provide good guidelines for the suitable selection of a lubricant for refrigeration compressors (especially for new, environmentally friendly refrigerants, such as R452A). The research was carried out for mixtures of zeotropic refrigerants (R404A, R452A) with polyester oils (POE) and natural refrigerant (R600a) with mineral oils (MO). In each group of refrigerants, different mechanisms of oil–refrigerant mixture formation occur. Each refrigerant was tested with three different compressor oils recommended for each other for alternative uses in refrigeration systems.

7 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
KGKasper Górny
Kasper Górny
NINatalia Idaszewska
Natalia Idaszewska
ZSZuzanna Sydow
Zuzanna Sydow
KBKrzysztof Bieńczak
Krzysztof Bieńczak
Many organisations consider environmentally friendly activities, including the reduction of their carbon footprint, to be a significant aspect of their operation. In this study, a mathematical model was used to calculate the carbon footprint of food products at different stages of internal transport, using data on internal transport energy consumption. It was shown that for most products, the highest carbon footprint was related to the raw material transport stage from the loading/unloading point to the workstations on the production line. Broccoli showed the highest carbon footprint for internal transport per tonne of raw material. The study proposes methods of reducing the internal transport-related carbon footprint, which involves reorganising the distribution of goods in the warehouse and using nutritionally valuable vegetable waste in the production of food products.

30 June 2016 in Tribologia
Verified
Journal Article
Closed access
KGKasper Górny
Kasper Górny
Arkadiusz StachowiakArkadiusz Stachowiak
Arkadiusz Stachowiak
TPTyczewski Przemysław
Tyczewski Przemysław
WZWiesław ZWIERZYCKI
Wiesław ZWIERZYCKI
The problems with lubrication in refrigeration compressors are usually caused by the presence of the oil-refrigerant mixture in friction nodes. One cannot assess lubricity properties of oil under its operating conditions based on test results that characterize oil exclusively. For this purpose, it is necessary to test the lubricity properties of the oil-refrigerant mixture. The article presents the concept of an assessment method for the lubricity properties of oils for refrigeration compressors in a mixture with a refrigerant. The essential elements of the proposed method are the procedure for selecting wear test duration time (τt) and the oil-refrigerant mixture formation time (τm).

30 June 2016 in Tribologia
Verified
Journal Article
Closed access
KGKasper Górny
Kasper Górny
Arkadiusz StachowiakArkadiusz Stachowiak
Arkadiusz Stachowiak
TPTyczewski Przemysław
Tyczewski Przemysław
WZWiesław ZWIERZYCKI
Wiesław ZWIERZYCKI
Current legal regulations concerning ozone-depleting substances and greenhouse gases result in a dynamic return to the use of natural refrigerants such as hydrocarbons. However, they are gases included in the A3 (combustible) security group, and that is why they are now mainly used in devices with low performance (mainly in household refrigerators). The most widely used hydrocarbon as a refrigerant in this group of devices is R600a (isobutene). The article presents a comparative assessment of the lubricity properties of oil-refrigerant mixtures of three mineral oils with R600a. The assessment was based on a sample wear volume of the block-on-ring node under the conditions approximating the operation of the compressor after an extensive standstill period. The oil/refrigerant mixture was obtained as a result of an appropriately extended mutual contact of both substances in a closed chamber.