Current laboratory diagnostic approaches for virus detection give reliable results, but they require a lengthy procedure, trained personnel, and expensive equipment and reagents; hence, they are not a suitable choice for home monitoring purposes. This paper addresses this challenge by developing a portable impedimetric biosensing system for the identification of COVID-19 patients. This sensing system has two main parts: a throwaway two-working electrode (2-WE) strip and a novel read-out circuit, specifically designed for simultaneous signal acquisition from both working electrodes. Highly reliable electrochemical signal tracking from multiplex immunosensors provides a potential for flexible and portable multi-biomarker detection. The electrodes’ surfaces were functionalized with SARS-CoV-2 Nucleocapsid Antibody enabling the selective detection of Nucleocapsid protein (N-protein) along with self-validation in the clinical nasopharyngeal swab specimens. The proposed programmable highly sensitive impedance read-out system allows for a wide dynamic detection range, which makes the sensor capable of detecting N-protein concentrations between 0.116 and 10,000 pg/mL. This lightweight and economical read-out arrangement is an ideal prospect for being mass-produced, especially during urgent pandemic situations. Also, such an impedimetric sensing platform has the potential to be redesigned for targeting not only other infectious diseases but also other critical disorders.
10 April 2023 in IEEE Transactions on Instrumentation and Measurement
This paper presents a portable impedimetric biosensor for detecting infectious diseases such as SARS-CoV-2 Infections. A bio-ready sensing electrode functionalized with SARS-CoV-2 nucleocapsid antibody was employed to quantitatively convert the concentration of nucleocapsid protein (N-protein) into impedance changes. In this paper, we proposed a readout system with a dynamic input range of 200 Ω to 1 MΩ magnitude and 0 to 180° phase. The resolution of this device is 1% and 6.5° for measuring the magnitude and phase, respectively. Herein we demonstrate and discuss the proposed system’s functionality, sensitivity, and selectivity using the clinical swab samples. As per these results, this readout system is suitable for the detection of N-protein ranging up to 10,000 pg/mL with a resolution of 56 fg/mL. The proposed impedimetric sensing system can be adopted for the detection of infectious diseases in the future. This low-cost (<$80) device using off-the-shelf is a unique candidate for batch production purposes during urgent pandemic situations.