Xuehua Wu

Dr. Xuehua Wu

Faculty of Science, Kunming University of Science and Technology, Kunming, Yunnan, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2016 in Green Chemistry
Verified
Journal Article
Closed access
PDF file
FZFan Zhang
Fan Zhang
Xuehua WuXuehua Wu
Xuehua Wu
MYMin Yao
Min Yao
Zhen FangZhen Fang
Zhen Fang
Yi-Tong WangYi-Tong Wang
Yi-Tong Wang
The production of biodiesel from plant oil was catalyzed by a magnetic Na2SiO3@Ni/C catalyst, and H2 was given off by the deactivated catalyst from the by-product of glycerol.

9 January 2023 in Electronics
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
JZJingjing Zhao
Jingjing Zhao
Xuehua WuXuehua Wu
Xuehua Wu
ZXZhipeng Xu
Zhipeng Xu
WZWenbin Zhang
Wenbin Zhang
MHMingxing He
Mingxing He
In view of the fact that the partial discharge (PD) signal energy is mainly concentrated below hundreds of megahertz, the ultra-high frequency part of the energy is weak, and the interior space of the switchgear is narrow, this paper proposes a new method for PD detection of the switchgear based on near-field detection. Firstly, based on the principle of PD, the field characteristics of the signal in the switchgear are analyzed. After that, the probe is designed with an electric small loop structure. Based on its equivalent circuit, its measurement principle and amplitude frequency characteristics are analyzed. The influence of probe size and material on amplitude frequency characteristics is obtained by using simulation software High Frequency Structure Simulator (HFSS), and the probe parameters suitable for PD detection in the switchgear are determined. Finally, the performance of the probe is measured by network analyzer, and the PD signal is tested on the simulated PD test platform. The results show that the probe works in the frequency band of 10–200 MHz and can receive PD signals containing more energy information. In the operating frequency band, the reflection coefficient of the probe port is very large, and its interference to the signal near field is particularly small. The probe also has good frequency response characteristics, and the fluctuation in the frequency band is less than 5 dB, which can obtain more accurate PD signal characteristics in subsequent processing. In addition, the probe is passive, with dimensions of 166 mm in length, 104 mm in width, and 2 mm in thickness, which is suitable for placing in the switchgear with small internal space. The results of PD receiving test show that the probe can reflect the occurrence of PD remarkably and accurately.

25 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
ZWZhang Wenbin
Zhang Wenbin
RLRuikang Luo
Ruikang Luo
Xuehua WuXuehua Wu
Xuehua Wu
CXChungang Xu
Chungang Xu
CSChunguang Suo
Chunguang Suo
With the increasing use of underground cables, the quantity and quality of intermediate joints demanded are also increasing. The quality of the traditional crimping intermediate joint is easily affected by the actual process of the operator, which may lead to the heating of the crimping part of the wire core, affecting the insulation performance of the cable, and finally causing the joint to break. However, aluminothermic reactive technology has some problems, such as a high welding temperature and an uncontrollable reaction. In order to solve these problems, according to the brazing principle and microalloying method, the optimal content of In in Sn-1.5Cu-based solder was explored, and then the connection of the middle joint of a 10 kV cable was completed using a connecting die and electrical connection process. The contact resistance and tensile strength of the joint were tested to verify the feasibility of this method. The results show that the maximum conductivity of the solder with 3.8% and 5% In content can reach 3.236 × 106 S/m, and the highest wettability is 93.6%. Finally, the minimum contact resistance of the intermediate joint is 7.05 μΩ, which is 43% lower than that of the aluminothermic welded joint, and the tensile strength is close to that of the welded joint, with a maximum of 7174 N.