Agus Suprihanto

Dr. Agus Suprihanto

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Solechan SolechanSolechan Solechan
Solechan Solechan
ASAgus Suprihanto
Agus Suprihanto
SWSusilo Adi Widyanto
Susilo Adi Widyanto
JTJoko Triyono
Joko Triyono
DFD.F. Fitriyana
D.F. Fitriyana
CTC. Tezara
C. Tezara
Hydroxyapatite has the closest chemical composition to human bone. Despite this, the use of nano-hydroxyapatite (nHA) to produce biocomposite scaffolds from a mixture of polylactic acid (PLA) and polycaprolactone (PCL) using cold isostatic pressing has not been studied intensively. In this study, biocomposites were created employing nHA as an osteoconductive filler and a polymeric blend of PLA and PCL as a polymer matrix for prospective usage in the medical field. Cold isostatic pressing and subsequent sintering were used to create composites with different nHA concentrations that ranged from 0 to 30 weight percent. Using physical and mechanical characterization techniques such as Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and density, porosity, tensile, and flexural standard tests, it was determined how the nHA concentrations affected the biocomposite’s general properties. In this study, the presence of PLA, PCL, and nHA was well identified using FTIR, XRD, and SEM methods. The biocomposites with high nHA content showed intense bands for symmetric stretching and the asymmetric bending vibration of PO43−. The incorporation of nHA into the polymeric blend matrix resulted in a rather irregular structure and the crystallization became more difficult. The addition of nHA improved the density and tensile and flexural strength of the PLA/PCL matrix (0% nHA). However, with increasing nHA content, the PLA/PCL/nHA biocomposites became more porous. In addition, the density, flexural strength, and tensile strength of the PLA/PCL/nHA biocomposites decreased with increasing nHA concentration. The PLA/PCL/nHA biocomposites with 10% nHA had the highest mechanical properties with a density of 1.39 g/cm3, a porosity of 1.93%, a flexural strength of 55.35 MPa, and a tensile strength of 30.68 MPa.

21 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
Solechan SolechanSolechan Solechan
Solechan Solechan
ASAgus Suprihanto
Agus Suprihanto
SWSusilo Adi Widyanto
Susilo Adi Widyanto
JTJoko Triyono
Joko Triyono
DFD.F. Fitriyana
D.F. Fitriyana
CTC. Tezara
C. Tezara
Polylactic acid (PLA) and polycaprolactone (PCL) are synthetic polymers that are extensively used in biomedical applications. However, the PLA/PCL blend produced by ball milling, followed by pressure compaction and sintering, has not been extensively explored. The goal of this research is to investigate the effect of the composition of biomaterials derived from PLA and PCL prepared by ball milling, followed by pressure compaction and sintering, on mechanical and physical properties. PCL and PLA with various concentrations were blended utilizing a ball milling machine for 2 h at an 80-rpm rotation speed. The obtained mixture was placed in a stainless steel 304 mold for the compacting process, which uses a pressure of 30 MPa to create a green body. The sintering procedure was carried out on the green body created at 150 °C for 2 h using a digital oven. The obtained PLA/PCL blend was tested using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), Scanning electron microscopy (SEM), density, porosity, and three-point bending. Following the interaction between PCL and PLA in the PLA/PCL blend, the FTIR spectra and XRD diffractograms obtained in this work revealed a number of modifications in the functional groups and crystal phase. The 90PLA specimen had the best mechanical properties, with a maximum force and displacement of 51.13 N and 7.21 mm, respectively. The porosity of the PLA/PCL blend decreased with increasing PLA concentration so that the density and flexural properties of the PLA/PCL blend increased. The higher PCL content decreased the stiffness of the PLA molecular chain, consequently reducing its flexural properties.

4 August 2020 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
DWDwi Basuki Wibowo
Dwi Basuki Wibowo
ASAgus Suprihanto
Agus Suprihanto
Wahyu CaesarendraWahyu Caesarendra
Wahyu Caesarendra
SKSlamet Khoeron
Slamet Khoeron
AGAdam Glowacz
Adam Glowacz
MIMuhammad Irfan
Muhammad Irfan
Generally, there are two types of working style, i.e., some people work in sitting conditions, and the remaining work mostly in a standing position. For people working in a standing position, they can spend hours in a day doing their work standing. These people do not realize that it can cause medical issues, especially for the feet, namely biometric problems. In addition, several doctors in Indonesia are already aware of this issue and state that the biometric problems faced by those kinds of people can be predicted from the load distribution on the foot. However, the tool used by the doctors in Indonesia to measure biometric problems is not a digital tool. Therefore it is very difficult to measure and predict the biometric problems quantitatively. This study aims to develop a low-cost static load measuring device using force-sensing resistor (FSR) sensors. The measuring instrument is designed in the form of a pressure plate platform which consist of 30 FSR 402 sensors. The sensors are placed right underneath the display area of the foot, 15 sensors on the soles of the left and right feet. Ten students from the Department of Mechanical Engineering, Diponegoro University (five men and five women) were asked to stand on the platform. Each subject also measured foot length (FL) to estimate shoe size, foot area contact (FAC) for validation between genders, and foot type using the digital footprint tools. From the results of measurements obtained for the left foot in the medial mid foot area, i.e., in sensors 5 and 7, not exposed to the load, on almost all subjects except subject number 3 with a load of 0.196 kg on sensor 7. The highest average load occurs in the heel area i.e., sensor 1 measured 0.713 kg and the smallest average load occurs in the five sensors, with 0 kg. A static load gauge that is designed to be used to measure each leg area for subjects with a shoe size of 40–42 with low price to be held in hospital-orthopedic hospitals and biomechanical research centers.

4 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YUYusuf Umardani
Yusuf Umardani
DWDwi Basuki Wibowo
Dwi Basuki Wibowo
Wahyu CaesarendraWahyu Caesarendra
Wahyu Caesarendra
ASAgus Suprihanto
Agus Suprihanto
KPKirana Astari Pranoto
Kirana Astari Pranoto
A type of flatfoot can be analyzed accurately using the footprint when a human is standing; however, this method cannot be applied when a human is wearing orthotic shoes. This study aims to analyze flatfoot using the rearfoot angle (RFA) measurement. The result is then compared to a footprint measurement known as Cavanagh’s Arch Index (AI). A total of 31 static footprints of the participants consisting of 14 males and 17 females aged 18 to 25 years were collected. According to Cavanagh’s AI as a gold standard, the correlation equation was obtained as RFA = 46.04AI − 6.41 and RFA = 45.32AI − 6.26 for left and right foot, respectively. The correlation coefficient R2 for the left and the right foot is 0.63 and 0.73, respectively. Other statistical analyses using ANOVA and t-tests are presented in this paper. The correlation results obtained from this study are necessary for estimating the reduction in the degree of flatfoot when using orthotic shoes, which is difficult to calculate using the typical AI method from footprint measurements.

1 August 2024 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
ASAgus Suprihanto
Agus Suprihanto
Wahyu CaesarendraWahyu Caesarendra
Wahyu Caesarendra
DWDwi Basuki Wibowo
Dwi Basuki Wibowo
Marian BartoszukMarian Bartoszuk
Marian Bartoszuk
GVGyula Varga
Gyula Varga
RTV 10A silicone rubber composites have many applications in forming many medical products and one of the recent applications is for orthotic insoles. This is because the RTV silicon rubber has excellent flexibility, elasticity, and resistance against splitting. However, these mechanical...

20 July 2017 in ROTASI
Verified
Journal Article
Open access
PDF file
ASAgus Suprihanto
Agus Suprihanto
Biometallic materials for implant devices not only have to good corrosion resistance but also stable nonmagnetic properties. Various method have been developed for enhanced the corrosion resistance i.e low temperature gas nitriding treatments. Unfortunatelly, low temperature gas nitriding produce weakly ferromagnetic due the presence of expanded austenitic phases. Another treatments methods which is capable for improvement the mechanical properties is high temperature gas nitriding. However, the evaluation of magnetic properties of austenitic stainless steel 316L and 316LVM not yet investigation. The evaluation of magnetic properties of austenitis stainless steel 316L and 316LVM after high temperature gas nitriding treatments have been succesfully done. The magnetic properties are evaluated by vibrating sample magnetometre (VSM) test. The magnetic properties such as magnetic remenance, magnetic saturation and magnetic permeability are improved. As treated 316L and 316LVM have more stable non-magnetic properties and they more safe and compatible for MRI test