Ugochukwu Elele

Ugochukwu Elele


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
ANAzam Nekahi
Azam Nekahi
Arshad ArshadArshad Arshad
Arshad Arshad
Issouf FofanaIssouf Fofana
Issouf Fofana
Transformers play an essential role in power networks, ensuring that generated power gets to consumers at the safest voltage level. However, they are prone to insulation failure from ageing, which has fatal and economic consequences if left undetected or unattended. Traditional detection methods are based on scheduled maintenance practices that often involve taking samples from in situ transformers and analysing them in laboratories using several techniques. This conventional method exposes the engineer performing the test to hazards, requires specialised training, and does not guarantee reliable results because samples can be contaminated during collection and transportation. This paper reviews the transformer oil types and some traditional ageing detection methods, including breakdown voltage (BDV), spectroscopy, dissolved gas analysis, total acid number, interfacial tension, and corresponding regulating standards. In addition, a review of sensors, technologies to improve the reliability of online ageing detection, and related online transformer ageing systems is covered in this work. A non-destructive online ageing detection method for in situ transformer oil is a better alternative to the traditional offline detection method. Moreover, when combined with the Internet of Things (IoT) and artificial intelligence, a prescriptive maintenance solution emerges, offering more advantages and robustness than offline preventive maintenance approaches.

13 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
ANAzam Nekahi
Azam Nekahi
Arshad ArshadArshad Arshad
Arshad Arshad
KMKate McAulay
Kate McAulay
Issouf FofanaIssouf Fofana
Issouf Fofana
As the focus tilts toward online detection methodologies for transformer oil aging, bypassing challenges associated with traditional offline methods, such as sample contamination and misinterpretation, fiber optic sensors are gaining traction due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances that are typical in high-voltage environments. This study delves into the sensitivity analysis of intensity-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Our findings highlight that elongating sensing length detrimentally affects both linearity response and repeatability, largely attributed to a diminished resistance to noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity.

23 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
ANAzam Nekahi
Azam Nekahi
Arshad ArshadArshad Arshad
Arshad Arshad
Issouf FofanaIssouf Fofana
Issouf Fofana
KMKate McAulay
Kate McAulay
Transformers are indispensable components in any power networks, facilitating the delivery of generated electricity to consumers at the most secure voltage level. The insulation system of oil-filled transformers is critical for the safe operation of power transformers, although it undergoes consistent degradation over time. Similar to blood in a human body, the insulating fluid serves as condition monitoring medium. Most traditional oil ageing detection methodologies operate offline; thus they are most suitable for planned maintenance activities. However, these methods have their drawbacks including potential safety risks, contamination of samples, loss of productive hours, and the potential risk of overlooking early signs of ageing that could occur beyond the maintenance cycle window. The Myers Oil Quality Index Number (OQIN), derived from the quotient of interfacial tension (IFT) and total acid number (TAN) values, provides a tool for classifying transformer oil into seven distinct categories, expanding the potential for both offline and online oil applications. In this work, eighteen 750ml samples of natural ester oil (NEO) were procured, aged, and analysed using offline TAN and IFT techniques, and their respective values (IFT, TAN, and OQIN) were recorded. These experimental data sets were employed to verify and validate (V&V) an OQIN machine learning model. The model was further validated using existing mineral oil (MIN) data sets. The high-performance metrics, demonstrated in terms of accuracy, precision, sensitivity, specificity and F-Score, confirm the effectiveness of the model for online transformer oil ageing detection and classification. The bagged tree ensemble model showed the best performance for OQIN, NEO, MIN respectively in terms of accuracy (100%, 83.30%, 100%), precision (100%, 90%, 100%), sensitivity (100%, 88%, 100%), specificity (100%, 96%, 100%) and F-Score (100%, 84.76%, 100%). This development proposes the potential for a shift from traditional offline scheduled maintenance ageing detection methods to an online/Internet of Things (IoT) - based prescriptive ageing detection, thereby enhancing the reliability of transformer performance in situ.

3 October 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
ANAzam Nekahi
Azam Nekahi
Arshad ArshadArshad Arshad
Arshad Arshad
KMKate McAulay
Kate McAulay
Issouf FofanaIssouf Fofana
Issouf Fofana
In the realm of power delivery to end-users, transformers are indispensable, with their malfunctions leading to substantial economic, safety, and environmental repercussions. The need for persistent surveillance is accentuated for in-situ oil-filled transformers, given the potential degradation of oil and the emergence of related ageing by-products. As the focus tilts towards online detection methodologies for transformer oil ageing, bypassing challenges associated with traditional offline methods such as sample contamination and misinterpretation, fiber optic sensors are gaining trac-tion due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances typical in high-voltage environments. This work delves into the sensitivity analysis of intensi-ty-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Findings underscore that elongating the sensing length detrimentally affects both the linearity response and repeatability, largely attributed to the diminished resistance to external noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity.

25 March 2019 in International Journal of Engineering Trends and Technology
Verified
Journal Article
Closed access
NONkolika O.Nwazor
Nkolika O.Nwazor
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
Computerized Automatic Three Phase Data Logger for Power Stations

9 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
UEUgochukwu Akachi Elele
Ugochukwu Akachi Elele
Youssouf BrahamiYoussouf Brahami
Youssouf Brahami
Issouf FofanaIssouf Fofana
Issouf Fofana
ANAzam Nekahi
Azam Nekahi
Arshad ArshadArshad Arshad
Arshad Arshad
KMKate McAulay
Kate McAulay
Transformer oil ageing alters key physicochemical properties, notably the refractive index (RI), due to physical, particulate, and chemical changes. As a result, refractometric fibre-optic sensors have gained attention for enabling real-time monitoring and overcoming the limitations of traditional offline diagnostics. This study explores the use of a Fabry–Pérot phase-modulated fibre optic sensor (FISO FRI RI Sensor) for in-situ ageing detection in four industrial transformer oils: natural ester, synthetic ester, Nytro Bio 300X (vegetable-based), and Polaris GX (mineral-based). The oils were thermally aged under controlled conditions following degassing and drying. The sensor performance was evaluated using key metrics, including repeatability, thermal response, settling time, and linearity. Results show high repeatability (with standard deviations below 7 × 10−5 RIU and repeatability coefficients under 2 × 10−4 RIU), stable thermal response (~0.0004 RIU/°C), and strong thermal linearity (R2 > 0.99) across all samples. Natural ester and Nytro Bio 300X exhibited the most stable and consistent sensor responses, while synthetic ester and mineral oils showed greater variability due to temperature-induced RI shifts. These findings demonstrate the reliability and precision of this Fabry–Pérot phase-modulated sensor for online transformer oil condition monitoring, with strong potential for integration into smart grid diagnostics.