Despite the benefits of mammography investigations, some studies have shown that X-ray exposure from the mammography screening itself can statistically cause breast cancer in a small fraction of women. Therefore, a dose reduction in mammography is desirable. At the same time, there is a demand for a higher spatial resolution in mammographic imaging. The most promising way to achieve these goals is the use of advanced photon-processing semiconductor X-ray detectors with optimum sensor materials. This study addresses the investigation of the optimum semiconductor sensor material for mammography in combination with the photon-processing detector Medipix3RX. The influence of K-shell fluorescence from the sensor material on the achievable contrast-to-noise ratio is investigated, as well as the attenuation efficiency. The three different sensor materials, CdTe, GaAs, and Si are studied, showing advances of CdTe-sensors for mammography. Furthermore, a comparison of the contrast-to-noise ratio between a clinical Se-detector and Medipix3RX detectors with Si-and CdTe-sensors is shown using a self-produced mammography phantom that is based on real human tissue.
The presented work describes the capabilities of a state-of-the-art spectroscopic photon-counting hybrid pixel detector for use in non-destructive testing, as a contaminant detector with potential uses in the food and pharmaceutical industries. A pharmaceutical hard capsule containing vitamin powder, contaminated with Steel (ST) and Tungsten (W) was prepared under controlled conditions. Both contaminants are distinguished from the powder by combining sub-pixel imaging with spectroscopic imaging analysis, made possible by the use of a 2 mm CdZnTe sensor coupled to a Timepix3 ASIC, operated in Time-over-Threshold and Time-of-Arrival mode. The sub-pixelization technique achieves a spatial resolution of 18.3 μm, with a maximum photon flux of 2.5× 106 photons/s· cm2. For the spectral analysis technique implemented, each energy bin image is energy-weighted, with weights optimally defined by considering the bin contrast and noise behavior, and combined to form an integrated-spectrum enhanced image with increased contaminant visibility. Contrast-to-Noise Ratio (CNR) for each contaminant type was used for performance assessment of the approach. A CNR increase of 106% above the reference unweighted-spectrum image was achieved for the ST contaminant, while the denser W contaminant showed a CNR increase of 80%. This means that the presented spectroscopic imaging technique is feasible for implementation in material visibility enhancement.
1 March 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
We report measurements of muon flux over the sky of the city of Bogotá at 4°35′56′′ north latitude, 74°04′51′′ west longitude, and an altitude of 2657 m above sea level, carried out with a hodoscope composed of four stations of plastic scintillators located equidistant over a distance of 4.8 m. Measurements were taken at different zenith (θ) angles within the range , the muon flux data is statistically consistent with a dependence, with a per degree of freedom near unity. If instead, we fit to a we obtain with a lower per degree of freedom. Integrating the muon flux distribution as a function of the zenith angle over the solid angle of the upper Earth’s hemisphere allows an estimation of the atmospheric vertical muon rate at the altitude and latitude of Bogota obtaining a value of . This estimate is consistent with an independent direct measurement of the vertical muon flux with all detectors stacked horizontally. These measurements play a key role in the further development of detectors, aimed to perform muon imaging of Monserrate Hill, located in Bogotá, where the detectors will be placed at similar locations to those used in the present study.
1 August 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera. The sensor’s electron mobility–lifetime product and resistivity are studied across bias voltages ranging from −100 V to −3000 V, obtaining values of = (1.2 ± 0.1) × 10−3 cm2V−1, and two linear regions with resistivities of and . Additionally, two calibration methodologies are assessed to determine the most suitable for Compton applications, achieving an energy resolution of 16.3 for the 137Cs photopeak. The electron’s drift time in the sensor is estimated to be (122.3 ± 7.4) ns using cosmic muons. Finally, a Compton reconstruction of two simultaneous point-like sources is performed, demonstrating the detector’s capability to accurately locate radiation hotspots with a ∼51 cm resolution.