Simon Procz

Dr. Simon Procz


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
EHElias Hamann
Elias Hamann
TKThomas Koenig
Thomas Koenig
MZMarcus Zuber
Marcus Zuber
ACA. Cecilia
A. Cecilia
ATAnton Tyazhev
Anton Tyazhev
TBTilo Baumbach
Tilo Baumbach

24 June 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
SPSimon Procz
Simon Procz
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
CACarlos Avila
Carlos Avila
JRJorge Racedo
Jorge Racedo
RRRoberto Javier Rueda-Esteban
Roberto Javier Rueda-Esteban
MFMichael Fiederle
Michael Fiederle
Despite the benefits of mammography investigations, some studies have shown that X-ray exposure from the mammography screening itself can statistically cause breast cancer in a small fraction of women. Therefore, a dose reduction in mammography is desirable. At the same time, there is a demand for a higher spatial resolution in mammographic imaging. The most promising way to achieve these goals is the use of advanced photon-processing semiconductor X-ray detectors with optimum sensor materials. This study addresses the investigation of the optimum semiconductor sensor material for mammography in combination with the photon-processing detector Medipix3RX. The influence of K-shell fluorescence from the sensor material on the achievable contrast-to-noise ratio is investigated, as well as the attenuation efficiency. The three different sensor materials, CdTe, GaAs, and Si are studied, showing advances of CdTe-sensors for mammography. Furthermore, a comparison of the contrast-to-noise ratio between a clinical Se-detector and Medipix3RX detectors with Si-and CdTe-sensors is shown using a self-produced mammography phantom that is based on real human tissue.

20 October 2011 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SPSimon Procz
Simon Procz
Martin Peter PichotkaMartin Peter Pichotka
Martin Peter Pichotka
JLJ. Lubke
J. Lubke
EHElias Hamann
Elias Hamann
RBR. Ballabriga
R. Ballabriga
MFMichael Fiederle
Michael Fiederle
Pixelated photon counting semiconductor X-ray detectors like the Medipix feature adjustable energy thresholds allowing selective counting of photons of a specified energy. This development permits for energy selective X-ray imaging with advanced material information. Furthermore the photon counting function principle of these detectors allows X-ray imaging with reduced noise, providing contrast improvement in low contrast objects. The aim of this study is to analyze the behavior of the new Medipix3 detector, especially regarding flatfield correction for X-ray imaging applications. First high resolution low contrast X-ray images and energy selective X-ray images acquired with the Medipix3 detector are presented as well in this paper.

1 April 2008 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
SPSimon Procz
Simon Procz
MFMichael Fiederle
Michael Fiederle
MKM. Kunzer
M. Kunzer
KKK. Köhler
K. Köhler
JWJ. Wagner
J. Wagner
We show that the conduction band structure of dilute AlxGa1−xAs1−yNy with x⩽0.37 and y⩽0.04 can be described consistently by the experimentally motivated band anticrossing model. The interband transition energies E− , E−+Δ0 , and E+ have been derived from a full line shape fit to photomodulated reflectance (PR) spectra recorded at room temperature. The PR data were taken (a) from a series of Al0.06Ga0.94As1−yNy samples with y⩽0.04 and (b) from a set of AlxGa1−xAs0.99N0.01 layers with x⩽0.37 . The latter series covers the range of Al concentrations where the AlxGa1−xAs band gap energy EM is expected to cross the nitrogen-induced energy level EN . The resulting nitrogen- and Al-concentration dependent interband transition energies are described by the band anticrossing model using a matrix element for the coupling between the nitrogen-induced states and the extend lowest conduction band states of CMN=2.32eV and a nitrogen level energy EN=(1.625+0.069x)eV , the latter measured with respect to the GaAs valence band edge.

1 March 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
CACarlos Avila
Carlos Avila
MPMaria L. Pérez-Lara
Maria L. Pérez-Lara
LMLuis Mendoza
Luis Mendoza
SPSimon Procz
Simon Procz

1 August 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
CNCarlos Navarrete
Carlos Navarrete
SPSimon Procz
Simon Procz
MSMichael Kilian Schütz
Michael Kilian Schütz
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
JFJulian Fey
Julian Fey
MFMichael Fiederle
Michael Fiederle