Juan Sebastian Useche Parra

Mr. Juan Sebastian Useche Parra

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Journal of Instrumentation
Verified
Journal Article
Open access
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
MSM.K. Schütz
M.K. Schütz
GRG. Roque
G. Roque
JFJ. Fey
J. Fey
CAC. Avila
C. Avila
SPS. Procz
S. Procz
Nowadays, the detection of backscatter X-rays has become an essential part of road security scanners, where individuals are at risk of an accidental exposure to the pulsed photon radiation fields generated by the devices that implement this technique. Dose to soft-tissue measurements of a pulsed radiation field generated by a commercial cargo X-ray backscattering device are presented using a Timepix3 detector. To accurately estimate the imparted dose, the energy spectrum of a backscattering cargo scanner is measured with a thick CdZnTe hybrid semiconductor pixel detector. The deconvolution of this measured spectrum is performed and the contributions to the dose are calculated by means of the mass energy-absorption coefficients for soft-tissue. This methodology was assessed through a Monte-Carlo simulation, together with verification measurements using thermoluminescent detectors (TLDs) as a standard dosimetry system. Measurements of direct irradiation, for a 30 s scan with the device at 2 m from the detector, yielded a dose of (4.9 ± 0.7) μGy and (3.6 ± 0.3) μGy for the Timepix3 and TLDs, respectively. In a simulated cargo environment, with the detector behind a 1 mm thick steel wall, 30 s scan time, and 2 m source to detector distance, the dose measured by the Timepix3 was (1.7 ± 0.1) μGy, while for the TLDs (1.4 ± 0.6) μGy, showing that the proposed methodology has a similar response as compared to a standard dosimetry system.

13 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
MSMichael Kilian Schütz
Michael Kilian Schütz
MFMichael Fiederle
Michael Fiederle
SPSimon Procz
Simon Procz
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera. The sensor’s electron mobility–lifetime product and resistivity are studied across bias voltages ranging from −100 V to −3000 V, obtaining values of μeτe = (1.2 ± 0.1) × 10−3 cm2V−1, and two linear regions with resistivities of ρI=(5.8±0.2) GΩ cm and ρII=(4.1±0.1) GΩ cm. Additionally, two calibration methodologies are assessed to determine the most suitable for Compton applications, achieving an energy resolution of 16.3 keV for the 137Cs photopeak. The electron’s drift time in the sensor is estimated to be (122.3 ± 7.4) ns using cosmic muons. Finally, a Compton reconstruction of two simultaneous point-like sources is performed, demonstrating the detector’s capability to accurately locate radiation hotspots with a ∼51 cm resolution.

30 December 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
EIEdilio Steven Cely Iza
Edilio Steven Cely Iza
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
CACarlos Avila
Carlos Avila
SPSimon Procz
Simon Procz
The limited visibility of breast lesions underlying silicone implants hampers the early detection of breast cancer-like features, highlighting the need for imaging methods that improve contrast behind implants. The present study investigates, both computationally and experimentally, the feasibility of combining spectrum optimization and material decomposition to enhance the contrast-to-noise ratio (CNR) of micro-calcifications in mammographic phantoms with breast implants. The goal is to reconstruct an image with improved CNR by using recovered energy-independent maps of two reference materials and applying the Beer–Lambert equation to the energy bin with the highest identified CNR. The computational study evaluates the approach using aluminum oxide and hydroxyapatite micro-calcifications embedded in standard-density breast tissue and partially obscured by silicone breast implants of four different thicknesses. Energy-bin images are generated from a simulated monochromatic x-ray source and weighted using four Tungsten polychromatic spectra with an additional filter: aluminum (1 mm) at three voltages and rhodium (0.05 mm) at 28 kVp. The experimental study independently assesses the same approach using aluminum oxide micro-calcifications within the Mammo-156 phantom, partially covered by a 250 cc compressed silicone implant. Polymethyl methacrylate slabs are added to simulate a 5 cm-thick breast. The experimental setup consists of a Tungsten micro-focus x-ray source and a hybrid photon counting detector Timepix3, which enables the acquisition of energy bin images and the estimation of entrance radiation dose. Exposure time is adjusted to achieve an entrance radiation dose of approximately 4 mGy for each spectrum, which is a typical value used in mammography. Simulation results demonstrate an enhancement in CNR in the reconstructed images compared with both the input energy-bin images with the highest CNR and the energy-weighted images, for both types of micro-calcifications and in both regions-inside and outside the implant-across all implant thicknesses. Experimental results also show the enhancement in CNR in the reconstructed images under realistic imaging conditions, for micro-calcifications in both inside and outside the implant region.

23 November 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MSMichael Kilian Schütz
Michael Kilian Schütz
JFJulian Fey
Julian Fey
SPSimon Procz
Simon Procz
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
GRGerardo Roque
Gerardo Roque
MFMichael Fiederle
Michael Fiederle
The reliable identification of multiple elements in a single X-ray exposure is advantageous in various fields of interest like medicine, nondestructive materials research, homeland security, waste management, and the mining industry. Elements of interest can be identified by analyzing how an X-ray transmission spectrum correlates with the element’s K-edge. Timepix3-based photon-counting detectors offer the possibility of spectroscopic X-ray imaging, allowing to record the changes in the transmission spectrum and, consequently, for element identification. This article presents element identification using a single X-ray image recorded with a 2 mm CdZnTe Timepix3 detector. The analysis is based on the K-edge method, analyzing sharp edges in the absorption spectrum of an exposed object. The work describes the follow-up investigation of a material discrimination study utilizing several discrete energy thresholds. Single layers of 200 μm thick foils of different metals have been investigated as elements of interest. No overlaying elements or composites have been used in the absorption phantom. The method shown is limited to a specific absorption ratio inside the element, which means the influence of the absorber on the spectrum measured must result in a recognizable K-edge. Within this work, it is possible to identify eight out of nine different elements of the absorption phantom with K-edges distributed over an energy spectrum from 8 to 70 keV.

5 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
MLMaria Laura Perez Lara
Maria Laura Perez Lara
EIEdilio Steven Cely Iza
Edilio Steven Cely Iza
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
JBJesus Bermudez
Jesus Bermudez
SPSimon Procz
Simon Procz
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility because strong attenuation lowers contrast, while conventional rhodium (Rh) K-edge filtering suppresses part of the high-energy spectral tail. This study presents a Monte Carlo framework for spectroscopic mammography using a voxelated 1 mm thick cadmium telluride (CdTe) sensor and a first-order detector interaction model to evaluate energy-dependent image quality. The model reproduces fluorescence and inter-voxel energy redistribution in CdTe, but not the full detector chain, and remains idealized with respect to charge transport, carrier collection, threshold dispersion, and pile-up. Energy-resolved simulations in the 10–50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and to form integrated-spectrum (IS) images for four tested spectra. For the dense-breast calcium hydroxyapatite (HA) speck detection task considered here, and under the present simulation assumptions, replacing the standard 28 kVp + 50 μm Rh spectrum with 28 kVp + 1 mm Al increased the simulated IS image CNR by 23.11%, with an approximately 5% increase in estimated primary-incident air kerma at the phantom entrance plane. Preliminary experimental implant-phantom images were included as a qualitative feasibility check, showing a trend consistent with simulations. Within the limits of this task-specific simulation, the results suggest that preserving the transmitted high-energy tail can improve HA speck visibility for the present 1 mm CdTe photon-counting detector, with the 28 kVp + 1 mm Al spectrum outperforming the other tested cases.

26 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
GRGerardo Alfonso Roque
Gerardo Alfonso Roque
MLMaria Laura Perez Lara
Maria Laura Perez Lara
EIEdilio Steven Cely Iza
Edilio Steven Cely Iza
JPJuan Sebastian Useche Parra
Juan Sebastian Useche Parra
JBJesus Bermudez
Jesus Bermudez
SPSimon Procz
Simon Procz
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility due to strong attenuation, while conventional rhodium (Rh) K-edge filtering typically suppresses high-energy photons. This study presents a Monte Carlo-based simulation and optimization framework for spectroscopic mammography using a voxelated Cadmium Telluride (CdTe) sensor, enabling quantitative evaluation of energy-dependent image quality. The system accurately simulates sensor fluorescence and inter-voxel energy redistribution, enabling direct comparability with real-world performance. Energy-resolved simulations in the 10-50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and identify optimal spectral regions and filter configurations. Replacing the standard Rh filter with aluminum (Al) filtration increased CNR by more than 23% with only a ~5% increase in entrance surface dose (ESD), significantly improving the visibility of hydroxyapatite microcalcifications, even behind dense tissue or implants. The shown work demonstrates practical guidelines and analysis for energy-resolved imaging optimizations obtained from simulations. The results imply that spectroscopic photon-counting detectors and methods can enhance dense-breast mammography image quality while maintaining low patient dose.