Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging technique that gives real-time dynamic feedback on surgical procedures. iOCT was first employed in vitreoretinal surgery, but successively served as a guidance in several anterior segment surgical approaches: keratoplasty, implantable Collamer lens (ICL) implantation, and cataract surgery. Among all of those approaches, the unbeatable features of iOCT are fully exploited in anterior and posterior lamellar keratoplasty, and the purpose of this review is to focus on the advantages and shortfalls of iOCT in these techniques, in order to assess whether this technology could be a real step forward. In deep anterior lamellar keratoplasty (DALK), iOCT is useful to evaluate the needle depth into the corneal stroma, the big bubble dissection plane, and residual stromal bed, thus aiding the standardization of the technique and the reduction of failures. In Descemet stripping automated endothelial keratoplasty (DSAEK), iOCT allowed for clear visibility of fluid at the graft/host interface, allowing for immediate rescue maneuvers and granting the best graft apposition. In Descemet membrane endothelial keratoplasty (DMEK), iOCT can track the lenticule unfolding in real time and assess graft orientation even in severe hazy corneas, thus optimizing surgical times, as well as avoiding the use of potentially hazardous exterior markers (such as the “S” stamp) and preventing unnecessary manipulation of the graft. Overall, the role of iOCT appeared crucial in several complicated cases, overcoming the difficulties of poor visualization in a fast, non-invasive way, thus raising this approach as possible gold standard for challenging conditions. Further improvements in the technology may enable autonomous centering and tracking, overcoming the current constraint of instrument-induced shadowing.
Purpose: To describe the advantages of Ngenuity 3D digital filters for enhancing visualization during cataract and corneal transplant surgery. Methods: All surgeries were performed by the same experienced surgeon (L.M.) using the Ngenuity 3D heads-up visualization system connected to a microscope. Images were simultaneously captured with and without the filter in each of the following phases: endothelial evaluation, capsulorhexis, capsule rupture, vitreous leak, cortex removal, visco removal, corneal suture, descemetorhexis, DMEK graft preparation and insertion. Results: In cataract surgery, green and monochrome filters facilitate capsulorhexis in difficult situations by highlighting the anterior capsule and can improve visualization of a posterior capsular tear. The enhanced contrast of the monochrome filter is also useful for cortex and viscoelastic removal. In corneal surgery, the green filter highlights the rim of the DMEK graft during tissue preparation, the yellow filter enhances the contrast of the stained DMEK graft in the anterior chamber, the monochrome filter simplifies descemetorhexis by improving visualization of the Descemet/endothelial layer and allows a better view in red saturated images while performing sutures. Conclusions: Ngenuity digital filters have the potential to enhance tissue visualization during cataract and corneal surgeries, especially in poor visibility conditions.
17 July 2003 in Graefe's Archive for Clinical and Experimental Ophthalmology
Background: Mirvetuximab soravtansine (MIRV) improves outcomes in FRα-positive, platinum-resistant ovarian cancer; however ocular adverse events (OAEs), particularly corneal epithelial toxicity, are frequent and warrant structured ophthalmologic monitoring. Methods: In this retrospective observational study, 31 consecutive patients receiving MIRV for FRα-positive gynecologic malignancies underwent standardized ophthalmic assessments at baseline and prior to each treatment cycle (every 21 days). The protocol included best corrected visual acuity (BCVA), slit-lamp biomicroscopy, anterior-segment optical coherence tomography (AS-OCT), corneal topography, and tear film analysis. OAEs were graded according to the Common Terminology Criteria for Adverse Events (CTCAE) v5.0, based on symptom severity and functional impairment. Results: OAEs occurred in all patients (31/31, 100%), predominantly grade 1–2. Corneal epithelial toxicity was documented in 28/31 patients (90.3%), while no grade ≥ 3 events were observed. Symptoms typically developed 7–14 days after the second infusion. AS-OCT and corneal topography consistently revealed epithelial microcysts and surface irregularities, which were usually detected during scheduled pre-cycle ophthalmologic evaluations. Tear-film instability (break-up time ≤ 5 s) developed in 19/31 patients (61.3%), generally within 10 days after the second infusion, and improved in all but 2 patients (6.5%) following prophylactic lubrication. Transient refractive changes occurred in 28/31 patients (90.3%) and were associated with a temporary BCVA reduction (mean nadir ~20/32 Snellen), followed by recovery during follow-up. Conclusions: MIRV-related ocular alterations are frequent but reversible and clinically manageable. Multimodal imaging combined with functional and refractive assessment provides sensitive markers of corneal epithelial toxicity and supports integrated ophthalmologic monitoring to preserve visual function and maintain oncologic treatment continuity.
13 September 2022 in European Journal of Ophthalmology
In this report we illustrate the ophthalmologic assessment of two patients affected by Proteus Syndrome (PS), an extremely rare genetic disorder. Case #1 describes a 26 year old male patient followed for multiple ophthalmic anomalies: a limbal dermoid cyst, a unilateral cataract, bilateral nystagmus, severe myopia and unilateral optic nerve head drusen. Case #2 describes a 20 year old female patient referred to our Ophthalmology Department for a routine ophthalmologic evaluation after being treated for 3 years with Miransertib (an experimental AKT-pathway inhibitor). Both patients underwent a complete ophthalmologic examination and a multimodal imaging evaluation. The multimodal imaging approach has revealed useful to evaluate both cases in detail and to keep track of disease evolution over time, moreover providing helpful features to further characterize this rare syndrome.