Zhen Qiu

Zhen Qiu

Auto-generated profile, based on publicly available information

Zhen Qiu

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WSWajiha Shahid
Wajiha Shahid
ZQZhen Qiu
Zhen Qiu
XDXiyu Duan
Xiyu Duan
HLHaijun Li
Haijun Li
TWThomas Wang
Thomas Wang
KOKenn Oldham
Kenn Oldham
High frequency large scanning angle electrostatically actuated microelectromechanical systems (MEMS) mirrors are used in a variety of applications involving fast optical scanning. A 1-D parametrically resonant torsional micromirror for use in biomedical imaging is analyzed here with respect to operation by duty-cycled square waves. Duty-cycled square wave excitation can have significant advantages for practical mirror regulation and/or control. The mirror's nonlinear dynamics under such excitation is analyzed in a Hill's equation form. This form is used to predict stability regions (the voltage-frequency relationship) of parametric resonance behavior over large scanning angles using iterative approximations for nonlinear capacitance behavior of the mirror. Numerical simulations are also performed to obtain the mirror's frequency response over several voltages for various duty cycles. Frequency sweeps, stability results, and duty cycle trends from both analytical and simulation methods are compared with experimental results. Both analytical models and simulations show good agreement with experimental results over the range of duty cycled excitations tested. This paper discusses the implications of changing amplitude and phase with duty cycle for robust open-loop operation and future closed-loop operating strategies.

13 February 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
ZQZhen Qiu
Zhen Qiu
CRChoong-Ho Rhee
Choong-Ho Rhee
JCJongsoo Choi
Jongsoo Choi
TWThomas D. Wang
Thomas D. Wang
KOKenn Oldham
Kenn Oldham
A thin-film piezoelectric microactuator using a novel combination of active vertical translational scanning and passive resonant rotational scanning is presented. Thin-film lead-zirconate-titanate unimorph bending beams surrounding a central platform provide nearly 200-μm displacement at 18 V with bandwidth greater than 200 Hz. Inside the platform, a mirror mount, or mirror surface, supported by silicon dioxide spring beams can be excited to resonance by low-voltage; high-frequency excitation of the outer PZT beams. Over ±5.5° mechanical resonance is obtained at 3.8 kHz and ±2 V. The combination of large translational vertical displacements and high-speed rotational scanning is intended to support real-time cross-sectional imaging in a dual axes confocal endomicroscope.

28 March 2012
Verified
Book Chapter
Open access
PDF file
WPWibool Piyawattanametha
Wibool Piyawattanametha
ZQZhen Qiu
Zhen Qiu

1 January 2010
Verified
Conference Paper
Closed access
PDF file
KOKenn Oldham
Kenn Oldham
XLXianke Lin
Xianke Lin
ZQZhen Qiu
Zhen Qiu
TWThomas Wang
Thomas Wang
JPJeffrey S. Pulskamp
Jeffrey S. Pulskamp
RPRonald G. Polcawich
Ronald G. Polcawich
A novel thin-film piezoelectric vertical actuator with integrated strain gage position sensor is described, with sensor performance in simulated sliding mode control examined. The actuator utilizes four bending-beam thin-film lead-zirconate-titanate (PZT) legs to generate net translational out-of-plane motion of almost 100 μm, with higher speed and lower voltages than most MEMS vertical actuators. In addition, a portion of the top platinum electrode on the piezoelectric thin-film is used to perform position sensing, and shown to have good sensitivity during experimental operation of the actuator. A dynamic model of the stage based on a hysteresis model derived to fit experimental piezoelectric strain coefficient behavior is presented, and used to predict stage performance during sliding mode control using the integrated strain gage.

1 May 2013 in Gastroenterology
Verified
Journal Article
Closed access
ZQZhen Qiu
Zhen Qiu
SKSupang Khondee
Supang Khondee
XDXiyu Duan
Xiyu Duan
BJBishnu P. Joshi
Bishnu P. Joshi
EREmily Rabinsky
Emily Rabinsky
TWThomas Wang
Thomas Wang