Enrico Sangregorio

Mr. Enrico Sangregorio

Università degli studi di catania, Catania, Sicilia, Italy
+2

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FRFrancesco Romano
Francesco Romano
GMGiuliana Milluzzo
Giuliana Milluzzo
FMfabio di martino
fabio di martino
MDMaria Cristina D'Oca
Maria Cristina D'Oca
GFGiuseppe Felici
Giuseppe Felici
Massimo CamardaMassimo Camarda
Massimo Camarda
Ultra-high dose rate (UHDR) beams for FLASH radiotherapy present significant dosimetric challenges. Although novel approaches for decreasing or correcting ion recombination in ionization chambers are being proposed, applicability of ionimetric dosimetry to UHDR beams is still under investigation. Solid-state sensors have been recently investigated as a valuable alternative for real-time measurements, especially for relative dosimetry and beam monitoring. Among them, Silicon Carbide (SiC) represents a very promising candidate, compromising between the maturity of Silicon and the robustness of diamond. Its features allow for large area sensors and high electric fields, required to avoid ion recombination in UHDR beams. In this study, we present simulations and experimental measurements with the low energy UHDR electron beams accelerated with the ElectronFLASH machine developed by the SIT Sordina company (IT). The response of a newly developed 1 × 1 cm2 SiC sensor in charge as a function of the dose-per-pulse and its radiation hardness up to a total delivered dose of 90 kGy, was investigated during a dedicated experimental campaign, which is, to our knowledge, the first characterization ever done of SiC with UHDR-pulsed beams accelerated by a dedicated ElectronFLASH LINAC. Results are encouraging and show a linear response of the SiC detector up to 2 Gy/pulse and a variation in the charge per pulse measured for a cumulative delivered dose of 90 kGy, within ±0.75%.

9 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
EMElisabetta Medina
Elisabetta Medina
ESEnrico Sangregorio
Enrico Sangregorio
ACAndreo Crnjac
Andreo Crnjac
FRFrancesco Romano
Francesco Romano
GMGiuliana Milluzzo
Giuliana Milluzzo
Massimo CamardaMassimo Camarda
Massimo Camarda
Silicon carbide (SiC), thanks to its material properties similar to diamond and its industrial maturity close to silicon, represents an ideal candidate for several harsh-environment sensing applications, where sensors must withstand high particle irradiation and/or high operational temperatures. In this study, to explore the radiation tolerance of SiC sensors to multiple damaging processes, both at room and high temperature, we used the Ion Microprobe Chamber installed at the Ruđer Bošković Institute (Zagreb, Croatia), which made it possible to expose small areas within the same device to different ion beams, thus evaluating and comparing effects within a single device. The sensors tested, developed jointly by STLab and SenSiC, are PIN diodes with ultrathin free-standing membranes, realized by means of a recently developed doping-selective electrochemical etching. In this work, we report on the changes of the charge transport properties, specifically in terms of the charge collection efficiency (CCE), with respect to multiple localized proton irradiations, performed at both room temperature (RT) and 500 °C.

30 June 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
AMAlessandro Meli
Alessandro Meli
AMAnnamaria Muoio
Annamaria Muoio
RRRiccardo Reitano
Riccardo Reitano
ESEnrico Sangregorio
Enrico Sangregorio
LCLucia Calcagno
Lucia Calcagno
Francesco La ViaFrancesco La Via
Francesco La Via
The aim of this work was a deep spectroscopical characterization of a thick 4H SiC epitaxial layer and a comparison of results between samples before and after a thermal oxidation process carried out at 1400 °C for 48 h. Through Raman and photoluminescence (PL) spectroscopies, the carrier lifetimes and the general status of the epilayer were evaluated. Time-resolved photoluminescence (TRPL) was used to estimate carrier lifetime over the entire 250 µm epilayer using different wavelengths to obtain information from different depths. Furthermore, an analysis of stacking fault defects was conducted through PL and Raman maps to evaluate how these defects could affect the carrier lifetime, in particular after the thermal oxidation process, in comparison with non-oxidated samples. This study shows that the oxidation process allows an improvement in the epitaxial layer performances in terms of carrier lifetime and diffusion length. These results were confirmed using deep level transient spectroscopy (DLTS) measurements evidencing a decrease in the Z1/2 centers, although the oxidation generated other types of defects, ON1 and ON2, which appeared to affect the carrier lifetime less than Z1/2 centers.

22 May 2025 in Materials
Verified
Journal Article
Open access
PDF file
AMAlfio Samuele Mancuso
Alfio Samuele Mancuso
ESEnrico Sangregorio
Enrico Sangregorio
AMAnnamaria Muoio
Annamaria Muoio
SLSaverio De Luca
Saverio De Luca
MKMatteo Hakeem Kushoro
Matteo Hakeem Kushoro
Francesco La ViaFrancesco La Via
Francesco La Via
The objective of the proposed work was to investigate the electrical performance of a 250 µm-thick 4H-SiC p-n junction detector after irradiation with DT neutrons (14.1 MeV energy) at high temperature (500 °C). The results showed that the current–voltage (I-V) characteristics of the unirradiated SiC detector were ideal, with an ideality factor close to 1.5. A high electron mobility (µn) and built-in voltage (Vbi) were also observed. Additionally, the leakage current remained very low in the temperature range of 298–523 K. High-temperature irradiation caused a deviation from ideal behaviour, leading to an increase in the ideality factor, decreases in the µn and Vbi values, and a significant rise in the leakage current. Studying the capacitance–voltage (C-V) characteristics, it was observed that neutron irradiation induced reductions in both Al-doped (p+-type) and N-doped (n−-type) 4H-SiC carrier concentrations. A comprehensive investigation of the deep defect states and impurities was carried out using deep-level transient spectroscopy (DLTS) in the temperature range of 85–750 K. In particular, high-temperature neutron irradiation influenced the behaviours of both the Z1/2 and EH6/7 traps, which were related to carbon interstitials, silicon vacancies, or anti-site pairs.

18 December 2023 in Materials
Verified
Journal Article
Open access
PDF file
ESEnrico Sangregorio
Enrico Sangregorio
LCLucia Calcagno
Lucia Calcagno
EMElisabetta Medina
Elisabetta Medina
ACAndreo Crnjac
Andreo Crnjac
MJMilko Jakšić
Milko Jakšić
Massimo CamardaMassimo Camarda
Massimo Camarda
In recent times, ion implantation has received increasing interest for novel applications related to deterministic material doping on the nanoscale, primarily for the fabrication of solid-state quantum devices. For such applications, precise information concerning the number of implanted ions and their final position within the implanted sample is crucial. In this work, we present an innovative method for the detection of single ions of MeV energy by using a sub-micrometer ultra-thin silicon carbide sensor operated as an in-beam counter of transmitted ions. The SiC sensor signals, when compared to a Passivated Implanted Planar Silicon detector signal, exhibited a 96.5% ion-detection confidence, demonstrating that the membrane sensors can be utilized for high-fidelity ion counting. Furthermore, we assessed the angular straggling of transmitted ions due to the interaction with the SiC sensor, employing the scanning knife-edge method of a focused ion microbeam. The lateral dimension of the ion beam with and without the membrane sensor was compared to the SRIM calculations. The results were used to discuss the potential of such experimental geometry in deterministic ion-implantation schemes as well as other applications.

27 October 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
EMElisabetta Medina
Elisabetta Medina
GTG. Trovato
G. Trovato
LCL. Calcagno
L. Calcagno
SKS. Kalbfleisch
S. Kalbfleisch
MBM. Birri
M. Birri
Massimo CamardaMassimo Camarda
Massimo Camarda
Conventional beam intensity monitor technologies, such as `gold-meshes' and `diamond conductive thin films', currently applied to tender and soft X-ray beams, encounter numerous application challenges, including diffraction effects, low signal strength, non-uniform transparency, and lack of position information. This study explores the potential of very thin (<2 µm) silicon carbide free-standing membranes, as in-line, minimally interfering beam intensity and position monitors, with high-lateral resolution, for soft and tender X-ray beamlines. Initial experimental assessments were conducted at the NanoMAX beamline at MAX IV to analyze the performance of such very thin devices in monitoring tightly focused (<1 µm FWHM) beams. The tests revealed that employing four-quadrant sensor layouts on such thin sensors resulted in significant charge collection losses in the regions between the quadrants and, under high electric field conditions, in charge multiplication effects (avalanche effects). Through Sentaurus TCAD theoretical simulations, the limitations of the four-quadrant design for such applications and the potential of an alternative technology (resistive X-ray beam postion monitor) were clarified.