This article deals with the hygrothermal performance of wooden beam ends embedded in brick masonry walls. The real-scale experiment involving three interior insulation systems with different water vapor resistances and different treatments of joist pockets was monitored for three consecutive years. The moisture load of test walls was controlled during the experiment. First, humidity of indoor air was increased in the cold season (2016–2017). Then, an artificial short-time intensive rain event brought liquid water onto the external surface of the test walls in July 2017. Despite relatively mild external climatic loads, relative humidity was unsatisfactorily high in unsealed joist pockets. Vapor and airtight sealing of the joist pockets improved the microclimate of the wooden beam ends. However, even in this case, relative humidity approached critical values for the onset of mold growth. The artificial rain load applied on the experimental walls noticeably worsened the hygrothermal conditions in the joist pockets. Relative humidity in the joist pockets further increased to a level where massive mold growth could be expected. Visual inspection of the wooden beam ends during reconstruction of the experiment, however, revealed only a small spot of mold on a single beam located in an unsealed joist pocket. Mold growth on samples of organic thermal insulation material was found by microscopic investigations. Molds were localized in small separated colonies. These in situ and laboratory investigations do not confirm the calculated values of mold growth index. In conclusion, sealing of wooden beam ends improved their hygrothermal performance in the experiment.
The possible influence of anatomical sections of wood on mold growth was investigated by means of a laboratory experiment. The selected fungi, Aspergillus sp., Penicillium sp., and Alternaria sp. were inoculated by spraying on the surface of wood specimens prepared from pine (Pinus sylvestris) and spruce (Picea abies). The incubation was carried out under stable environmental conditions (temperature of 22 °C, relative humidity of 75, 87, and 95%) over three months. Mold growth was evaluated based on regular microscopic and macroscopic observations. The recorded mold coverage fractions and the qualitative indicators of mold development were later expressed by a dimensionless mold index. The differences in mold growth in the anatomical sections of wood were found to be relatively insignificant. In contrast, comparison of measured data with other experimental studies showed large differences, especially in the initial growth phase. The discrepancy is probably related to differences among the experimental protocols. It is concluded that laboratory mold growth studies would be improved if a common standardized methodology was developed and followed.
This paper deals with mathematical modeling of mold growth on wood. The logistic growth equation is used to model mold growth phenomena in changing environmental conditions. Microscopic mold coverage fraction is used in the logistic equation to represent mold development on a material surface over time. The current state-of-the-art dynamic Finnish mold growth model is used as the reference model for development of the logistic mold growth model. The optimal values of mold growth coefficient are estimated by simulations of mold growth under constant environmental conditions and by finding the best agreement with the Finnish mold growth model using mathematical optimization methods. It is shown that the mold growth coefficient can be approximated as a function of relative humidity, temperature, wood species and the quality of the surface. The model parameters are then verified by a comparison with the Finnish mold growth model. In this case, cyclic step changes of constant relative humidity are used. Finally, the logistic mold growth model is compared with published experimental observations of mold growth. The discrepancy of mold growth models and experimental mold growth data, and possible improvements are discussed.
Wooden floors were traditionally used in brick apartment houses built at the turn of 20th century in many European cities. Thermal renovation of such houses often involves thermal insulation at interior side of external walls. Internal insulation makes microclimate in the vicinity of wooden beam ends colder and more humid. The real-scale experiment involving a part of wooden floor connected to a 30 cm thick masonry wall was monitored for two consecutive years. Measured data were used to compare microclimate in sealed and open joist pockets. Joist pockets were either placed in the masonry wall with plaster on both sides or placed in the same masonry wall insulated on the interior side (vapour open thermal insulation system). The measured results indicate that the sealing tape alone is not sufficient to keep the relative humidity in joist pockets below 85 % in cold climate and under high internal moisture load. The paper concludes that reasonable trade-off between thermal efficiency, thermal comfort and moisture safety is difficult to reach for masonry with internal insulation and wooden floors. Sealing provisions complemented by tempering of joist pockets are considered as two key technical measures for reliable hygro-thermal performance of wooden beam ends in full-brick masonry with interior thermal insulation in cold temperate climate.
21 November 2020 in IOP Conference Series: Earth and Environmental Science
This paper deals with vertical greenery applied on the external side of lightweight walls for industrial and storage buildings. The greenery is expected to have some positive impacts on the building performance, in particular reduction of building energy consumption and peak cooling power. The achievable benefits are however dependent on local climatic conditions, hygro-thermal properties of the building enclosure, the requirements for the indoor environment and on the system of greenery applied on the walls. The side-by-side real-scale experiment involving three different test walls was built in two test windows with dimensions of 3.0 x 3.2 m. A climatic test room with controlled indoor environment is located behind test windows. Two reference walls present current standard technical solutions constructed as metal frame filled with thermal insulation with metal sheets on the exterior side, either in direct contact with core wall or with ventilated air gap. The third wall replaces the external metal sheets by the system of baskets filled by soil substrate and greenery with integrated irrigation pipes. The experiment was built in June 2019 and is extensively monitored since beginning of July 2019. Temperatures, relative humidity, heat fluxes, moisture content of soil substrate, inflow and outflow of irrigation water, and environmental boundary conditions are continuously recorded. Results of the first year of monitoring are presented and discussed in the paper. The measured results showed reduction of daily peak values of heat flux on the internal surface during hot summer days and evaluated power of evaporative cooling.