In order to compensate for the hemispherical resonator gyroscope (HRG) dynamic output drift errors, a novel compensation method is presented. Through deriving the resonator motion equations and analyzing the mechanism of HRG dynamic output drift errors, it is found that the resonator defect nonuniformity is the main cause of the HRG dynamic output errors. By analyzing the mechanisms of these errors, the influence of these error sources is interacted and coupled, and it is difficult to analyze HRG output error mechanism and establish an error model comprehensively. We proposed a compensation prediction model for the HRG dynamic output to suppress the influence of these errors comprehensively. To establish the high precision HRG dynamic output compensation model, we proposed an improved variational mode decomposition (VMD) method to achieve an accurate HRG output. First, we used VMD to decompose the HRG output, and the optimal VMD decomposition parameters are achieved by genetic algorithm. In order to better achieve the effective information, the decomposed components of HRG drift are classified using the sample entropy. Then the mixed components are further processed using time frequency peak filtering. Finally, the accurate HRG output is achieved by reconstructing all the effective components. The accurate HRG output is used to construct the training set, and the high-precision HRG dynamic output prediction model is established by long short-term memory. The software compensation of the HRG dynamic output drift is realized by the prediction model. The experiment shows that the HRG dynamic output drift is mainly produced by the resonator nonuniformity, and it is strongly correlated with the standing wave azimuth, which verifies the correctness of the mechanism analysis. The HRG dynamic drift peak-peak value decreases to 5.715×10 -3 °/s, which verifies the effectiveness of the compensation method.
14 February 2025 in IEEE Transactions on Instrumentation and Measurement
In the article, the ultrahigh-precision identification and balance method for the first-to-third harmonics of mass defects of the hemispherical resonator are proposed. First, the mechanical analysis model of the hemispherical shell acting on the supporting stem is established, and the energy transfer mechanism from the hemispherical shell to the supporting stem is revealed. According to the theoretical analysis, the identification model and test method for the amplitude and azimuth of the first-to-third harmonics of mass defects based on the coupled vibration of the supporting stem are proposed, respectively. Second, the optical testing system is implemented for measuring the mass imperfection and damping anisotropy, which includes the amplitude-phase control system of the hemispherical shell with PXI platform as the core and the weak vibration signal extraction system of the supporting stem with the lock-in amplifier as a core. After that, the important etching process parameters are optimized based on the vibration energy function of the resonator and mass removal function of the ion beam for improving the efficiency and accuracy of the mass balance, and the etching path and time series of the ion beam are planned by the identification result of mass defects and calibration result of the etching efficiency. Finally, the mass balancing results indicate that the first-to-third harmonics of mass defects are reduced by 95.85%, 89.52%, and 81.69%. Correspondingly, the average of the quality factor is increased from $1.6616\times 10^{7}$ to $1.8364\times 10^{7}$ , the split of the quality factor is reduced from $3.9152\times 10^{6}$ to $9.7717\times 10^{4}$ , and the nonuniformity of the quality factor is decreased from 23.56% to 0.53%, which can significantly improve the vibration performance of the resonator.
On-field calibration for SINS often uses right hexahedron, but the influence of the structure errors, such as mutual position tolerances towards parallelism or the perpendicularity of two arbitrary planes of the hexahedron, on the calibration accuracy is often neglected. In this paper, a hexahedron structure error model and a comprehensive corresponding SINS calibration error model are developed based on hemispherical resonator gyroscope (HRGs). The proposed method introduces the comprehensive hexahedron errors through defining the normal vectors of the exterior surfaces of the hexahedron. A 24-position calibration scheme is designed to identify accelerometer-related errors, while a 48-rotation scheme is developed to identify gyro-related errors. The complete calibration procedure enables simultaneous identification of hexahedron structure errors, installation misalignments, scale factor errors, and biases. Experimental validation is conducted using a high-precision three-axis turntable, which simulates the hexahedron structure errors. The results show that the proposed method significantly improves the calibration accuracy of both accelerometers and HRGs compared with traditional methods. Furthermore, it reduces the accuracy requirements for the hexahedron structure, thus lowering the cost of SINS on-field calibration.
On-field calibration for SINS often uses right hexahedron, but the influence of the structure errors, such as mutual position tolerances towards parallelism or the per-pendicularity of two arbitrary planes of the hexahedron, on the calibration accuracy is often neglected. In this paper, a hexahedron structure error model and a comprehen-sive corresponding SINS calibration error model are developed based on hemispherical resonator gyroscope (HRGs). The proposed method introduces the comprehensive hexahedron errors through defining the normal vectors of the exterior surfaces of the hexahedron. A 24-position calibration scheme is designed to identify accelerome-ter-related errors, while a 48-rotation scheme is developed to identify gyro-related er-rors. The complete calibration procedure enables simultaneous identification of hexa-hedron structure errors, installation misalignments, scale factor errors, and biases. Ex-perimental validation is conducted using a high-precision three-axis turntable, which simulates the hexahedron structure errors. The results show that the proposed method significantly improves the calibration accuracy of both accelerometers and HRGs compared with traditional methods. Furthermore, it reduces the accuracy require-ments for the hexahedron structure, thus lowering the cost of SINS on-field calibration.