Sensors and actuators are the core components of all mechatronic systems used in a broad range of diverse applications. A relatively new and rapidly evolving area is the one of rehabilitation and assistive devices that comes to support and improve the quality of human life. Novel exoskeletons have to address many functional and cost-sensitive issues such as safety, adaptability, customization, modularity, scalability, and maintenance. Therefore, a smart variable stiffness actuator was developed. The described approach was to integrate in one modular unit a compliant actuator with all sensors and electronics required for real-time communications and control. This paper also introduces a new method to estimate and control the actuator's torques without using dedicated expensive torque sensors in conditions where the actuator's torsional stiffness can be adjusted by the user. A 6-degrees-of-freedom exoskeleton was assembled and tested using the technology described in this paper, and is introduced as a real-life case study for the mechatronic design, modularity, and integration of the proposed smart actuators, suitable for human-robot interaction. The advantages are discussed together with possible improvements and the possibility of extending the presented technology to other areas of mechatronics.
Human–robot interaction sensing is a compulsory feature in modern robotic systems where direct contact or close collaboration is desired. Rehabilitation and assistive robotics are fields where interaction forces are required for both safety and increased control performance of the device with a more comfortable experience for the user. In order to provide an efficient interaction feedback between the user and rehabilitation device, high performance sensing units are demanded. This work introduces a novel design of a multi-axis force sensor dedicated for measuring pelvis interaction forces in a rehabilitation exoskeleton device. The sensor is conceived such that it has different sensitivity characteristics for the three axes of interest having also movable parts in order to allow free rotations and limit crosstalk errors. Integrated sensor electronics make it easy to acquire and process data for a real-time distributed system architecture. Two of the developed sensors are integrated and tested in a complex gait rehabilitation device for safe and compliant control.
The last decades, rehabilitation has become a challenging context for mechatronical engineering. From the state-of-the-art it is seen that the field of prosthetics offers very promising perspectives to roboticist. Today’s prosthetic feet tend to improve amputee walking experience by delivering the necessary push-off forces while walking. Therefore, several new types of (compliant) actuators are developed in order to fulfill the torque and power requirements of a sound ankle-foot complex with minimized power consumption. At the Vrije Universiteit Brussel, the Robotics and Multibody Mechanics research group puts a lot of effort in the design and development of new bionic feet. In 2013, the Ankle Mimicking Prosthetic (AMP-) Foot 2, as a proof-of-concept, showed the advantage of using the explosive elastic actuator capable of delivering the full ankle torques ( $$\pm 120$$ ± 120 Nm) and power ( $$\pm 250$$ ± 250 W) with only a 60 W motor. In this article, the authors present the AMP-Foot 3, using an improved actuation method and using two locking mechanisms for improved energy storage during walking. The article focusses on the mechanical design of the device and validation of its working principle.
Evaluating human–exoskeleton interaction typically requires experiments with human subjects, which raises safety issues and entails time-consuming testing procedures. This paper presents a mechatronic replica of a human leg, which was designed to quantify physical interaction dynamics between exoskeletons and human limbs without the need for human testing. In the first part of this work, we present the mechanical, electronic, sensory system and software solutions integrated in our leg replica prototype. In the second part, we used the leg replica to test its interaction with two types of commercially available wearable devices, i.e. an active full leg exoskeleton and a passive knee orthosis. We ran basic test examples to demonstrate the functioning and benchmarking potential of the leg replica to assess the effects of joint misalignments on force transmission. The integrated force sensors embedded in the leg replica detected higher interaction forces in the misaligned scenario in comparison to the aligned one, in both active and passive modalities. The small standard deviation of force measurements across cycles demonstrates the potential of the leg replica as a standard test method for reproducible studies of human-exoskeleton physical interaction.
With the growing popularity of Human–Robot Interactions, a series of robotic assistive devices have been created over the last decades. However, due to the lack of easily integrable resources, the development of these custom made devices turns out to be long and expensive. Therefore, the SMARCOS, a novel off-the-shelf Smart Variable Stiffness Actuator for human-centered robotic applications is proposed in this paper. This modular actuator combines compliant elements and sensors as well as low-level controller and high-bandwidth communication. The characterisation of the actuator is presented in this manuscript, followed by two use-cases wherein the benefits of such technology can be truly exploited. The actuator provides a lightweight design that can serve as the building blocks to facilitate the development of robotic applications.