Ekaterina Kuznetsova

Ms. Ekaterina Kuznetsova

Polytechnical Institute, South Ural State University, Chelyabinsk, Chelyabinskaya Oblast’, Russia
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Bulletin of the South Ural State University Series "Power Engineering"
Verified
Journal Article
Open access
PDF file
Vladimir KanoveiVladimir Kanovei
Vladimir Kanovei
SUSouth Ural State University
South Ural State University
Maksim GrigorevMaksim Grigorev
Maksim Grigorev
EKEkaterina Kuznetsova
Ekaterina Kuznetsova
Alexander AnikinAlexander Anikin
Alexander Anikin
NLN.A. Loginova
N.A. Loginova
This article discusses engineering methods for calculating the operating modes of asynchronous electric drives with frequency control with a reduced main magnetic flux. Magnetization currents and rotor currents are calculated by methods formed on the basis of simplified equivalent circuits for induction motors and vector diagrams. The conditions for the minimum stator current are given, it is proved that this state corresponds to the equality of the amplitudes of the magnetizing current and the rotor current (reactive and active currents, respectively). This provision makes it possible to estimate the current of the rotor of an asynchronous electric motor when the main magnetic flux is weakened, and the calculation of the rotor and magnetization currents is also carried out according to experimental data. The proposed calculation methods are necessary for optimizing the operating modes of asynchronous electric drives operating with a load less than the nominal one. This optimization consists in reducing the maximum amplitude of the stator voltage. The proposed methods make it possible to evaluate the decrease in the magnetization current and the increase in the rotor current, which may turn out to be excessive. В данной статье рассматриваются инженерные методы расчетов режимов работы асинхронных электроприводов с частотным управлением при уменьшенном основном магнитном потоке. Токи намагничивания и токи ротора рассчитываются методами, сформированными на базе упрощенных схем замещения асинхронных двигателей и векторных диаграмм. Приводятся условия минимального тока статора, доказывается, что это состояние соответствует равенству амплитуд тока намагничивания и тока ротора (реактивного и активного токов соответственно). Это положение позволяет дать оценку тока ротора асинхронного электродвигателя при ослаблении основного магнитного потока, а также производится расчет токов ротора и намагничивания по экспериментальным данным. Предложенные методы расчета необходимы при оптимизации режимов работы асинхронных электроприводов, работающих с нагрузкой меньше номинальной. Эта оптимизация заключается в снижении максимальной амплитуды статорного напряжения. Предлагаемые методы позволяют провести оценку происходящих при этом уменьшении тока намагничивания и увеличения тока ротора, которое может оказаться чрезмерным.

1 March 2019
Verified
Conference Paper
Closed access
ABA.E. Bychkov
A.E. Bychkov
EKEkaterina Kuznetsova
Ekaterina Kuznetsova
The article describes the comparative structures analysis of motions synchronization of middle and high power electric drives. It compares the structures of synchronization in the context of influencing the final operation of systems and hardware methods of synchronization according to application and maximal response. The mathematical tools are based on the approach of the motions division of each electric drives and of the presentation of its transfer function in the matrix form. The adjustment ranges and response of different system types are compared experimentally by an estimate of the data transfer response and of speed pulsation on low rotation frequency.

14 March 2024 in Mathematics
Verified
Journal Article
Open access
PDF file
Vladimir KanoveiVladimir Kanovei
Vladimir Kanovei
EKEkaterina Kuznetsova
Ekaterina Kuznetsova
Alexander AnikinAlexander Anikin
Alexander Anikin
ABAlexander Baldenkov
Alexander Baldenkov
The article proposes a criterion for the existence of sliding processes according to the frequency characteristics of the control device and the control object. It is shown that the conditions for the existence of slip are equivalent to the conditions for the absolute stability of equivalent circuits of the original systems with a variable structure. This approach is proposed by the authors as an alternative to the method of phase trajectories and state space equations used by other researchers. Frequency criteria make it possible to formulate several practical engineering provisions that are very important for the implementation of this control method in real electric drives. The main conclusions are confirmed by simulation of both processes in systems with a variable structure and in equivalent circuits.

1 January 2024 in Bulletin of the South Ural State University Series "Power Engineering"
Verified
Journal Article
Open access
PDF file
SUSouth Ural State University
South Ural State University
Vladimir KanoveiVladimir Kanovei
Vladimir Kanovei
Maksim GrigorevMaksim Grigorev
Maksim Grigorev
EKEkaterina Kuznetsova
Ekaterina Kuznetsova
Alexander AnikinAlexander Anikin
Alexander Anikin
NLN.A. Loginova
N.A. Loginova
Asynchronous electric drive with frequency control are widely applied in the different industries. Traditional methods of analysis of operating mode of asynchronous electric drives are the equivalent circuits and vector diagrams. The result of their application is not most often visual and effective. Often the simplifications required for visual clarity are too great. This is the case with the interpretation of the popular optimization of power consumption by reducing the amplitude of the stator voltage. The article proposes a rationale for the modified equivalent circuits and vector diagrams, which makes it possible to evaluate how this optimization affects the entire complex of parameters and variables that characterize the mode of operation of an asynchronous electric drive - changes in rotation speed, slip and rotor current. Simplified vector diagrams and equivalent circuits are proposed, which allow estimating the active and reactive power flows in the electric drive and their changes while optimizing the stator voltage amplitude. Based on the proposed equivalent schemes, calculations were carried out showing the nature of the change in the rotor and stator currents with variations in the stator voltage. The proposed calculation methods made it possible to carry out a comprehensive assessment of the control method for asynchronous electric drives with the main magnetic flux, determined by the ratio of the amplitude of the voltage applied to the motor stator to its frequency, which is significantly lower than the nominal value. Асинхронные электроприводы с частотным регулированием широко применяются в самых разных отраслях промышленности. Традиционные методы анализа режимов работы асинхронных электроприводов – схемы замещения и векторные диаграммы – все еще широко применяются для анализа различных режимов работы. Достаточно часто результат их применения не слишком нагляден и эффективен. Часто упрощения, необходимые для наглядности, слишком значительны. Так обстоит дело с интерпретацией популярной оптимизации потребляемой мощности снижением амплитуды статорного напряжения. В статье предлагается обоснование измененных схем замещения и векторных диаграмм, позволяющее оценить, как эта оптимизация влияет на весь комплекс параметров и переменных, характеризующих режим работы асинхронного электропривода – изменения скорости вращения, скольжения и роторного тока. Предложены упрощенные векторные диаграммы и схемы замещения, которые позволяют оценить потоки активной и реактивной мощности в электроприводе и их изменения при оптимизации амплитуды статорного напряжения. На основании предложенных схем замещения проведены расчеты, показывающие характер изменения токов ротора и статора при вариациях статорного напряжения. Предложенные методы расчета позволили провести всестороннюю оценку метода управления асинхронными электроприводами при основном магнитном потоке, определяемым отношением амплитуды напряжения подаваемого на статор двигателя к его частоте, существенно ниже номинального значения.

1 May 2020
Verified
Conference Paper
Closed access
ABA. E. Bychkov
A. E. Bychkov
EKEkaterina Kuznetsova
Ekaterina Kuznetsova
AAA. V. Alexandrov
A. V. Alexandrov
The present article provides rationale for the necessity of automatic adjustment of the modern closed-loop systems of electric drives. The article gives a review of stages of the automatic adjustment and presents an experimental research of correlation between the required algorithms with real ones, which are applied in the typical industrial electric drives of different types. The characteristic of the symmetrical and modular optimums is given from the point of view of quality parameters of the electric drives control. The classification of current and speed loops adjustment in the relation to the symmetrical and modular optimums is given based on the experimental research. There are also recommendations given for improving the algorithms of the automatic adjustment for decreasing the time of commissioning the equipment.