David Kairuz-Cabrera

Mr. David Kairuz-Cabrera


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DKDavid Kairuz-Cabrera
David Kairuz-Cabrera
VHVictor Hernandez-Rodriguez
Victor Hernandez-Rodriguez
Olivier SchalmOlivier Schalm
Olivier Schalm
Alain MartinezAlain Martinez
Alain Martinez
Pedro Merino LasoPedro Merino Laso
Pedro Merino Laso
DSDaniellys Alejo Sánchez
Daniellys Alejo Sánchez
In developing nations, outdated technologies and sulfur-rich heavy fossil fuel usage are major contributors to air pollution, affecting urban air quality and public health. In addition, the limited resources hinder the adoption of advanced monitoring systems crucial for informed public health policies. This study addresses this challenge by introducing an affordable internet of things (IoT) monitoring system capable of tracking atmospheric pollutants and meteorological parameters. The IoT platform combines a Bresser 5-in-1 weather station with a previously developed air quality monitoring device equipped with Alphasense gas sensors. Utilizing MQTT, Node-RED, InfluxDB, and Grafana, a Raspberry Pi collects, processes, and visualizes the data it receives from the measuring device by LoRa. To validate system performance, a 15-day field campaign was conducted in Santa Clara, Cuba, using a Libelium Smart Environment Pro as a reference. The system, with a development cost several times lower than Libelium and measuring a greater number of variables, provided reliable data to address air quality issues and support health-related decision making, overcoming resource and budget constraints. The results showed that the IoT architecture has the capacity to process measurements in tropical conditions. The meteorological data provide deeper insights into events of poorer air quality.

10 May 2023
Verified
Book Chapter
Closed access
PDF file
EHErik Hernandez-Rodriguez
Erik Hernandez-Rodriguez
DKDavid Kairuz-Cabrera
David Kairuz-Cabrera
Alain MartinezAlain Martinez
Alain Martinez
RRRosa Amalia González Rivero
Rosa Amalia González Rivero
Olivier SchalmOlivier Schalm
Olivier Schalm

13 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
DSDaniellys Alejo Sánchez
Daniellys Alejo Sánchez
Olivier SchalmOlivier Schalm
Olivier Schalm
ACArianna Alvarez Cruz
Arianna Alvarez Cruz
ERErik Hernández Rodríguez
Erik Hernández Rodríguez
Alain MartinezAlain Martinez
Alain Martinez
MPMayra C. Morales Pérez
Mayra C. Morales Pérez
The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower, or cooling packs, while relative humidity was adjusted using glycerine solutions. Findings indicated that the auxiliary electrode signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the working electrode signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the auxiliary electrode signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability in the zero air calibration.

8 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
DSDaniellys Alejo Sánchez
Daniellys Alejo Sánchez
Olivier SchalmOlivier Schalm
Olivier Schalm
ACArianna Alvarez Cruz
Arianna Alvarez Cruz
EHErik Hernández-Rodríguez
Erik Hernández-Rodríguez
Alain MartinezAlain Martinez
Alain Martinez
MMMayra C. Morales-Pérez
Mayra C. Morales-Pérez
The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower or cooling packs, while relative humidity was adjusted using glycerin solutions. Findings indicated that the Auxiliary Electrode (AE) signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the Working Electrode (WE) signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the AE signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability of the zero calibration.