Ahmad Al Jaghsi

Dr. Ahmad Al Jaghsi

Clinical Sciences Department, Ajman University, Ajman, United Arab Emirates
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TKThomas Klinke
Thomas Klinke
ADAmro Daboul
Amro Daboul
JMJuliane Maron
Juliane Maron
TGTomasz Gredes
Tomasz Gredes
RPRalf Puls
Ralf Puls
RBReiner Biffar
Reiner Biffar
Artifacts caused by dental restorations, such as dental crowns, dental fillings and orthodontic appliances, are a common problem in MRI and CT scans of the head and neck. The aim of this in-vitro study was to identify and evaluate the artifacts produced by different dental restoration materials in CT and MRI images. Test samples of 44 materials (Metal and Non-Metal) commonly used in dental restorations were fabricated and embedded with reference specimens in gelatin moulds. MRI imaging of 1.5T and CT scan were performed on the samples and evaluated in two dimensions. Artifact size and distortions were measured using a digital image analysis software. In MRI, 13 out of 44 materials produced artifacts, while in CT 41 out of 44 materials showed artifacts. Artifacts produced in both MRI and CT images were categorized according to the size of the artifact. Metal based restoration materials had strong influence on CT and less artifacts in MRI images. Rare earth elements such as Ytterbium trifluoride found in composites caused artifacts in both MRI and CT. Recognizing these findings would help dental materials manufacturers and developers to produce materials which can cause less artifacts in MRI and CT images.

23 December 2024 in Frontiers in Dental Medicine
Verified
Journal Article
Open access
PDF file
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
AJAhmad Al Jaghsi
Ahmad Al Jaghsi
RJRohan Jagtap
Rohan Jagtap
VSViritpon Srimaneepong
Viritpon Srimaneepong
Artificial intelligence (AI) technology is being used in various fields and its use is increasingly expanding in dentistry. The key aspects of AI include machine learning (ML), deep learning (DL), and neural networks (NNs). The aim of this review is to present an overview of AI, its various aspects, and its application in biomedicine, dentistry, and dental biomaterials focusing on restorative dentistry and prosthodontics. AI-based systems can be a complementary tool in diagnosis and treatment planning, result prediction, and patient-centered care. AI software can be used to detect restorations, prosthetic crowns, periodontal bone loss, and root canal segmentation from the periapical radiographs. The integration of AI, digital imaging, and 3D printing can provide more precise, durable, and patient-oriented outcomes. AI can be also used for the automatic segmentation of panoramic radiographs showing normal anatomy of the oral and maxillofacial area. Recent advancement in AI in medical and dental sciences includes multimodal deep learning fusion, speech data detection, and neuromorphic computing. Hence, AI has helped dentists in diagnosis, planning, and aid in providing high-quality dental treatments in less time.

31 October 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ADAmro Daboul
Amro Daboul
CSChristian Schwahn
Christian Schwahn
GSGrit Schaffner
Grit Schaffner
SSSilvia Soehnel
Silvia Soehnel
SSStefanie Samietz
Stefanie Samietz
RBReiner Biffar
Reiner Biffar
The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures. MRI images of 43 subjects were obtained from the longitudinal population based cohort study SHIP-2 using a T1-weighted 3D sequence. Five examiners independently identified the three landmarks that form FH plane. Intra-examiner reproducibility and inter-examiner reliability, correlation coefficients (ICC), coefficient of variability and Bland-Altman plots were obtained for all landmarks coordinates to assess reproducibility. Intra-examiner reproducibility and inter-examiner reliability in terms of location and plane angulation were also assessed. Intra- and inter-examiner reliabilities for X, Y and Z coordinates of all three landmarks were excellent with ICC values ranging from 0.914 to 0.998. Differences among examiners were more in X and Z than in Y dimensions. The Bland–Altman analysis demonstrated excellent intra- as well as inter-examiner agreement between examiners in all coordinates for all landmarks. Intra-examiner reproducibility and inter-examiner reliability of the three landmarks in terms of distance showed mean differences between 1.3 to 2.9 mm, Mean differences in plane angulation were between 1.0° to 1.5° among examiners. This study revealed excellent intra-examiner reproducibility and inter-examiner reliability of Frankfort Horizontal plane through 3D landmark identification in MRI. Sufficiently stable landmark-based reference plane could be used for different treatments and studies.

30 July 2016 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
TMTorsten Mundt
Torsten Mundt
AJAhmad Al Jaghsi
Ahmad Al Jaghsi
BSBernd Schwahn
Bernd Schwahn
JHJanina Hilgert
Janina Hilgert
CLChristian Lucas
Christian Lucas
FHFriedhelm Heinemann
Friedhelm Heinemann
Acceptable short-term survival rates (>90 %) of mini-implants (diameter < 3.0 mm) are only documented for mandibular overdentures. Sound data for mini-implants as strategic abutments for a better retention of partial removable dental prosthesis (PRDP) are not available. The purpose of this study is to test the hypothesis that immediately loaded mini-implants show more bone loss and less success than strategic mini-implants with delayed loading. In this four-center (one university hospital, three dental practices in Germany), parallel-group, controlled clinical trial, which is cluster randomized on patient level, a total of 80 partially edentulous patients with unfavourable number and distribution of remaining abutment teeth in at least one jaw will receive supplementary min-implants to stabilize their PRDP. The mini-implant are either immediately loaded after implant placement (test group) or delayed after four months (control group). Follow-up of the patients will be performed for 36 months. The primary outcome is the radiographic bone level changes at implants. The secondary outcome is the implant success as a composite variable. Tertiary outcomes include clinical, subjective (quality of life, satisfaction, chewing ability) and dental or technical complications. Strategic implants under an existing PRDP are only documented for standard-diameter implants. Mini-implants could be a minimal invasive and low cost solution for this treatment modality. The trial is registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00007589 ( www.germanctr.de ) on January 13th, 2015.

1 January 2020 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
TMTorsten Mundt
Torsten Mundt
CSChristian Schwahn
Christian Schwahn
FHFriedhelm Heinemann
Friedhelm Heinemann
MSMartin Schimmel
Martin Schimmel
CLChristian Lucas
Christian Lucas
AJAhmad Al Jaghsi
Ahmad Al Jaghsi
Torsten Mundt, Prof, Dr Med Dent/Christian Schwahn, Dr Rer Med/Friedhelm Heinemann, Prof, Dr Med Dent/Martin Schimmel, Prof, Dr Med Dent, MAS Oral Biol/Christian Lucas, Dr Med Dent/Ahmad Al Jaghsi, Associate Prof, Dr Med Dent, MSc: Purpose: The aim of this investigation was to compare the chewing efficiency after immediate and delayed loading of mini-implants that served as supplementary support for removable partial dentures (RPDs). Materials and Methods: In this four-center randomized trial, patients who had RPDs in arches with unfavorable tooth distributions, ie, no canine and at most two posterior teeth in one or both quadrants, received strategic mini-implants with ball abutments. The mini-implants in group A were loaded immediately either by housings with O-rings (insertion torque ≥ 35 Ncm) or by soft relining material (insertion torque < 35 Ncm). In group B, the RPDs were only hollowed over the balls. After 4 months, the soft relined RPDs and all RPDs of group B received the housings. Masticatory efficiency was evaluated with a validated mixing ability test of two-colored chewing gum before surgery and 14 days, 4 months (before housing pickup), 4.5 months, and 12 months after surgery. The circular variance of hue was the measure of mixing. Results: From 76 participants with 79 RPDs, 38 each were randomly allocated to group A or B. In group A, the housings in six participants were picked up immediately, and the remaining RPDs were primarily soft relined. There was a significant group difference only after 4 months. The mixing ability was better after immediate loading than after delayed loading (P < .0001). In group B, the chewing efficiency was notably deteriorated after the RPDs were hollowed over the ball abutments. However, immediately after all housings were picked up, the chewing efficiency in both groups was substantially improved, and the variance of hue values after 1 year were very similar in the groups. Conclusion: The chewing performance can be improved by inserting supplementary mini-implants under existing RPDs with unfavorable tooth support. This improvement occurred faster by immediate loading than by delayed loading.

15 February 2023 in Children
Verified
Journal Article
Open access
PDF file
HIHafsa Al Idrissi
Hafsa Al Idrissi
LALovely Muthiah Annamma
Lovely Muthiah Annamma
DSDalya Jamal Taha Sharaf
Dalya Jamal Taha Sharaf
AJAhmad Al Jaghsi
Ahmad Al Jaghsi
HAHuda Mahmoud Abutayyem
Huda Mahmoud Abutayyem
With provisional restorations, properties such as flexural strength play a key role in maintaining the abutment teeth in position over the interim period until the final restorations are placed. This study aimed to evaluate and compare the flexural strength of four commonly used provisional resin materials. Ten identical 25 × 2 × 2 mm specimens were made from four different groups of provisional resin material, namely 1: SR Ivocron (Ivoclar Vivadent) cold-polymerized poly-methyl methacrylate (PMMA), 2: S Ivocron (Ivoclar Vivadent) heat-polymerized PMMA, 3: Protemp (3M Germany-ESPE) auto-polymerized bis-acryl composite, and 4: Revotek LC (GC Corp, Tokyo) light-polymerized urethane dimethacrylate resin. The mean values of the flexural strength of each group were calculated and the data were analyzed using one-way ANOVA and Tukey post hoc tests. The mean values (MPa) were as follows: for cold-polymerized PMMA, it was 125.90 MPa; for heat-polymerized PMMA, it was 140.00 MPa, with auto-polymerized bis-acryl composite 133.00 MPa; and for light-polymerized urethane dimethacrylate resin, it was 80.84 MPa. Thus, the highest flexural strength was recorded with heat-polymerized PMMA and the lowest flexural strength with light-polymerized urethane dimethacrylate resin, which was significantly low. The study did not detect a significant difference in the flexural strengths of cold PMMA, hot PMMA, and auto bis-acryl composite.