Islambek Baidilla

Islambek Baidilla


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
NZNurlan Zhangabay Zhangabayuly
Nurlan Zhangabay Zhangabayuly
IBIslambek Baidilla
Islambek Baidilla
ATAskhat Tagybayev
Askhat Tagybayev
BDBolat Duissenbekov
Bolat Duissenbekov
New energy-saving enclosing structures with air gaps are proposed; when calculating the temperature fields in the enclosing structures, the method of finite element analysis in the ANSYS environment was used. As a result of the study, the temperature fields of various enclosing structure solutions in various design options were analyzed. An analysis was made of the thermal resistance values of traditional and developed enclosing structures. The thermal resistance of the cladding with the use of two ventilated layers relative to the traditional enclosure, as well as the use of a heat-reflecting screen, depending on the environmental indicator, significantly increased the thermal resistance from 4.7% to 24.5% of the structure as a whole, which indicated the effectiveness of the constructive solution of the enclosure with two air gaps compared to the traditional constructive scheme of the enclosure. It was also found that the use of a heat-reflecting screen on the inside or on both sides has little effect on thermal resistance. At the same time, claddings were analyzed using horizontal channels. Where there was no efficiency, however, when taking into account the heat-reflecting screen in the horizontal channels, the efficiency of use increased from 1% to 8.4%, depending on the environment.

Verified
Journal Article
Open access
PDF file
NZNurlan Zhangabay Zhangabayuly
Nurlan Zhangabay Zhangabayuly
ATAskhat Tagybayev
Askhat Tagybayev
IBIslambek Baidilla
Islambek Baidilla
BSBayan Sapargaliyeva
Bayan Sapargaliyeva
GKGalymzhan Karshyga
Galymzhan Karshyga
PKPavel Kozlov
Pavel Kozlov
Precise meanings of thermophysical processes taking place in air gaps have decisive importance in composite cladding structure systems’ calculation and modeling. The climatic load conditions in Kazakhstan can significantly affect the microclimate of premises in general. In this work, a review study is carried out to obtain the relevant scientific literature on enclosing structures with air gaps under various climatic conditions. The review mainly covers research institutes from Sweden, Norway, France, Saudi Arabia, Russia, and China. On the issue of the air gap parameter’s influence on thermophysical processes, 16 papers were analyzed, and on the issue of air infiltration, 12 papers were analyzed. However, the review shows a lack of research in this area under various climatic conditions. At the same time, experience has shown that the principle of multilayer protection from climatic influences creates a favorable microclimate in buildings, but due to a possible temperature drop, wall structures made of composite building materials can be quite favorable under some conditions, and under others they may be less favorable. Therefore, working out a new energy-saving design with air gaps for climatic conditions with large temperature fluctuations during summer and winter is an urgent task.

14 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
NZNurlan Zhangabay Zhangabayuly
Nurlan Zhangabay Zhangabayuly
Marco BonoperaMarco Bonopera
Marco Bonopera
IBIslambek Baidilla
Islambek Baidilla
AUAkmaral Utelbayeva
Akmaral Utelbayeva
TTTimur Tursunkululy
Timur Tursunkululy
In this work, two new face structures of the open-air protection fence were investigated, where a method was proposed for analyzing the condensation of water vapor in the protection fence to search for a condensation zone. Another method for calculating the amount of condensed vapor in a multiwall protection fence with closed gap spacings was proposed. The analytical results illustrated that the magnitude of the range of temperature variations of the worked-out structures with gap spacings and without heat-reflecting screens was 7.14% lower, while the existence of heat-reflective screens reduced this value to 27.14%. The investigation of the water vapor transmission magnitude demonstrated that the steam permeability strength of the interior side and retaining walls of the developed buildings amounts to the standard one, while the usage of a locked air space with a thermo-reflective panel allows the movement of the appropriate condensing region over the external face of the fencing. Mass analysis of the precipitated vapor during the heating time of 1 m2 of the retaining wall showed that in face structures in closed gap spacings with heat-reflective screens, the mass of the precipitated vapor was 24.8% greater relative to that of the face without heat-reflective screens. Moreover, the examination of the absence of distillation in the oxygenated gap spacing proved that, in the gap spacing in the considered face structures, the condensate does not fall out such that there is no aggregation of humidity according to the annual balance. Furthermore, the drying time of the face structure with heat-reflecting screens was 17.9% longer than that of the traditional one. The research results can complement the works performed earlier by the authors, as well as be applied in the engineering and construction of buildings to save thermal power, considering the climatic features of the development region.