Kai Wang

Kai Wang

Auto-generated profile, based on publicly available information

Kai Wang

Laboratory of FMRI Technology USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California Los Angeles California USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KWKai Wang
Kai Wang
SMSamantha J. Ma
Samantha J. Ma
XSXingfeng Shao
Xingfeng Shao
CZChenyang Zhao
Chenyang Zhao
QSQinyang Shou
Qinyang Shou
DWDanny J. J. Wang
Danny J. J. Wang
Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.

11 January 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KWKai Wang
Kai Wang
XSXingfeng Shao
Xingfeng Shao
LYLirong Yan
Lirong Yan
SMSamantha J. Ma
Samantha J. Ma
JJJin Jin
Jin Jin
DWDanny J. J. Wang
Danny J. J. Wang