Chenyang Zhao

Chenyang Zhao

Auto-generated profile, based on publicly available information

Chenyang Zhao

Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine University of Southern California Los Angeles California USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
XSXingfeng Shao
Xingfeng Shao
CZChenyang Zhao
Chenyang Zhao
QSQinyang Shou
Qinyang Shou
KLKeith S. St Lawrence
Keith S. St Lawrence
DWDanny J. J. Wang
Danny J. J. Wang
Purpose: To present a pulse sequence and mathematical models for quantification of blood–brain barrier water exchange and permeability.Methods: Motion‐compensated diffusion‐weighted (MCDW) gradient‐and‐spin echo (GRASE) pseudo‐continuous arterial spin labeling (pCASL) sequence was proposed to acquire intravascular/extravascular perfusion signals from five postlabeling delays (PLDs, 1590–2790 ms). Experiments were performed on 11 healthy subjects at 3 T. A comprehensive set of perfusion and permeability parameters including cerebral blood flow (CBF), capillary transit time (τc), and water exchange rate (kw) were quantified, and permeability surface area product (PSw), total extraction fraction (Ew), and capillary volume (Vc) were derived simultaneously by a three‐compartment single‐pass approximation (SPA) model on group‐averaged data. With information (i.e., Vc and τc) obtained from three‐compartment SPA modeling, a simplified linear regression of logarithm (LRL) approach was proposed for individual kw quantification, and Ew and PSw can be estimated from long PLD (2490/2790 ms) signals. MCDW‐pCASL was compared with a previously developed diffusion‐prepared (DP) pCASL sequence, which calculates kw by a two‐compartment SPA model from PLD = 1800 ms signals, to evaluate the improvements.Results: Using three‐compartment SPA modeling, group‐averaged CBF = 51.5/36.8 ml/100 g/min, kw = 126.3/106.7 min−1, PSw = 151.6/93.8 ml/100 g/min, Ew = 94.7/92.2%, τc = 1409.2/1431.8 ms, and Vc = 1.2/0.9 ml/100 g in gray/white matter, respectively. Temporal SNR of MCDW‐pCASL perfusion signals increased 3‐fold, and individual kw maps calculated by the LRL method achieved higher spatial resolution (3.5 mm3 isotropic) as compared with DP pCASL (3.5 × 3.5 × 8 mm3).Conclusion: MCDW‐pCASL allows visualization of intravascular/extravascular ASL signals across multiple PLDs. The three‐compartment SPA model provides a comprehensive measurement of blood–brain barrier water dynamics from group‐averaged data, and a simplified LRL method was proposed for individual kw quantification.

24 August 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KWKai Wang
Kai Wang
SMSamantha J. Ma
Samantha J. Ma
XSXingfeng Shao
Xingfeng Shao
CZChenyang Zhao
Chenyang Zhao
QSQinyang Shou
Qinyang Shou
DWDanny J. J. Wang
Danny J. J. Wang
Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.

17 October 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
QSQinyang Shou
Qinyang Shou
CZChenyang Zhao
Chenyang Zhao
XSXingfeng Shao
Xingfeng Shao
KJKay Jann
Kay Jann
HKHosung Kim
Hosung Kim
DWDanny J. J. Wang
Danny J. J. Wang
Purpose: To present a Swin Transformer‐based deep learning (DL) model (SwinIR) for denoising single‐delay and multi‐delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) and other Transformer‐based methods.Methods: SwinIR and CNN‐based spatial denoising models were developed for single‐delay ASL. The models were trained on 66 subjects (119 scans) and tested on 39 subjects (44 scans) from three different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi‐delay ASL. A range of input conditions was tested for denoising single and multi‐delay ASL, respectively. The performance was evaluated using similarity metrics, spatial SNR and quantification accuracy of cerebral blood flow (CBF), and arterial transit time (ATT).Results: SwinIR outperformed CNN and other Transformer‐based networks, whereas pseudo‐3D models performed better than 2D models for denoising single‐delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo‐3D models and further improved when using M0 as input, but introduced greater biases for CBF quantification. Pseudo‐3D models with three slices achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi‐delay ASL, spatiotemporal denoising models had better performance than spatial‐only models with reduced biases in fitted CBF and ATT maps.Conclusions: SwinIR provided better performance than CNN and other Transformer‐based methods for denoising both single and multi‐delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.

25 June 2023 in NeuroImage
Verified
Journal Article
Open access
CZChenyang Zhao
Chenyang Zhao
XSXingfeng Shao
Xingfeng Shao
QSQinyang Shou
Qinyang Shou
SMSamantha J. Ma
Samantha J. Ma
SGSayim Gokyar
Sayim Gokyar
DWDanny Jj Wang
Danny Jj Wang
Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave = 0.4 mT/m, Gratio = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8°) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.

19 July 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SGSayim Gokyar
Sayim Gokyar
CZChenyang Zhao
Chenyang Zhao
SMSamantha J. Ma
Samantha J. Ma
DWDanny J. J. Wang
Danny J. J. Wang
Purpose: To predict subject‐specific local specific absorption rate (SAR) distributions of the human head for parallel transmission (pTx) systems at 7 T.Theory and methods: Electromagnetic energy deposition in tissues is nonuniform at 7 T, and interference patterns due to individual channels of pTx systems may result in increased local SAR values, which can only be estimated with very high safety margins. We proposed, designed, and demonstrated a multichannel 3D convolutional neural network (CNN) architecture to predict local SAR maps as well as peak‐spatial SAR (ps‐SAR) levels. We hypothesized that utilizing a three‐channel 3D CNN, in which each channel is fed by a map, a phase‐reversed map, and an MR image, would improve prediction accuracies and decrease uncertainties in the predictions. We generated 10 new head–neck body models, along with 389 3D pTx MRI data having different RF shim settings, with their B1 and local SAR maps to support efforts in this field.Results: The proposed three‐channel 3D CNN predicted ps‐SAR10g levels with an average overestimation error of 20%, which was better than the virtual observation points–based estimation error (i.e., 152% average overestimation). The proposed method decreased prediction uncertainties over 20% (i.e., 22.5%–17.7%) compared to other methods. A safety factor of 1.20 would be enough to avoid underestimations for the dataset generated in this work.Conclusion: Multichannel 3D CNN networks can be promising in predicting local SAR values and perform predictions within a second, making them clinically useful as an alternative to virtual observation points–based methods.

2 July 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
CZChenyang Zhao
Chenyang Zhao
TMThomas Martin
Thomas Martin
XSXingfeng Shao
Xingfeng Shao
JAJeffry R. Alger
Jeffry R. Alger
VDVinay Duddalwar
Vinay Duddalwar
DWDanny J. J. Wang
Danny J. J. Wang
CTP (Computed Tomography Perfusion) is widely used in clinical practice for the evaluation of cerebrovascular disorders. However, CTP involves high radiation dose (≥~200mGy) as the X-ray source remains continuously on during the passage of contrast media. The purpose of this study is to present a low dose CTP technique termed K-space Weighted Image Average (KWIA) using a novel projection view-shared averaging algorithm with reduced tube current. KWIA takes advantage of k-space signal property that the image contrast is primarily determined by the k-space center with low spatial frequencies and oversampled projections. KWIA divides each 2D Fourier transform (FT) or k-space CTP data into multiple rings. The outer rings are averaged with neighboring time frames to achieve adequate signal-to-noise ratio (SNR), while the center region of k-space remains unchanged to preserve high temporal resolution. Reduced dose sinogram data were simulated by adding Poisson distributed noise with zero mean on digital phantom and clinical CTP scans. A physical CTP phantom study was also performed with different X-ray tube currents. The sinogram data with simulated and real low doses were then reconstructed with KWIA, and compared with those reconstructed by standard filtered back projection (FBP) and simultaneous algebraic reconstruction with regularization of total variation (SART-TV). Evaluation of image quality and perfusion metrics using parameters including SNR, CNR (contrast-to-noise ratio), AUC (area-under-the-curve), and CBF (cerebral blood flow) demonstrated that KWIA is able to preserve the image quality, spatial and temporal resolution, as well as the accuracy of perfusion quantification of CTP scans with considerable (50-75%) dose-savings.