Kajetan Jeznach

Mr. Kajetan Jeznach


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2025 in Actuators
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
MPMaciej Pikuliński
Maciej Pikuliński
TOTomasz Osiak
Tomasz Osiak
KJKajetan Jeznach
Kajetan Jeznach
KZKrzysztof Zawalski
Krzysztof Zawalski
NONatalia Osiak
Natalia Osiak
Rehabilitation robotic systems have been developed to perform therapy with minimal supervision from a specialist. Hence, they require algorithms to assess and support patients’ motions. Artificial intelligence brings an opportunity to implement new exercises based on previously modelled ones. This study focuses on analysing the similarities in upper extremity movements during activities of daily living (ADLs). This research aimed to model ADLs by registering and segmenting real-life movements and dividing them into sub-tasks based on joint motions. The investigation used IMU sensors placed on the body to capture upper extremity motion. Angular measurements were converted into joint variables using Matlab computations. Then, these were divided into segments assigned to the sub-functionalities of the tasks. Further analysis involved calculating mathematical measures to evaluate the similarity between the different movements. This approach allows the system to distinguish between similar motions, which is critical for assessing rehabilitation scenarios and anatomical correctness. Twenty-two ADLs were recorded, and their segments were analysed to build a database of typical motion patterns. The results include a discussion on the ranges of motion for different ADLs and gender-related differences. Moreover, the similarities and general trends for different motions are presented. The system’s control algorithm will use these results to improve the effectiveness of robotic-assisted physiotherapy.

27 June 2024
Verified
Conference Paper
Open access
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
JOJan Oleksiuk
Jan Oleksiuk
KJKajetan Jeznach
Kajetan Jeznach
MAMehmet Emin Aktan
Mehmet Emin Aktan
Rehabilitation robots help physiotherapists in performing repetitive and tiring tasks. Moreover, they are also capable of automating therapy. However, for such an application, they require algorithms assessing patient’s performance and monitoring their safety. In therapy of lower extremities aided with exoskeletons, biosignal measurements can be used additionally to dynamics parameters to provide the mentioned analyses. The paper presents a concept of assessing the treatment based on electromyography of selected muscular groups and assessing the patient’s emotional states based on electroencephalography. The preliminary measurements enabled defining expected muscular activity dependent on the extremity configuration and emotional states based on the frequency analysis of the scalp regions. The presented methodology contains measurement flow, interpreting algorithms, and reactions of the systems to the defined states. Use of this can contribute to the development of minimally supervised systems for home-like environment use. The presented universal method is easily transferable to the exoskeleton-based systems, even different in terms of kinematics. Furthermore, it can also be analogically introduced to the systems dedicated to the upper extremities.

15 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
PKPiotr Kołodziejski
Piotr Kołodziejski
KZKrzysztof Zawalski
Krzysztof Zawalski
MPMaciej Pikuliński
Maciej Pikuliński
JOJan Oleksiuk
Jan Oleksiuk
DŚDaniel Ireneusz Śliż
Daniel Ireneusz Śliż
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.

12 May 2025 in IEEE International Conference on Rehabilitation Robotics (ICORR)
Verified
Conference Paper
Closed access
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
KZKrzysztof Zawalski
Krzysztof Zawalski
KJKajetan Jeznach
Kajetan Jeznach
JOJan Oleksiuk
Jan Oleksiuk
MAMehmet Emin Aktan
Mehmet Emin Aktan
PKPiotr Kołodziejski
Piotr Kołodziejski
The research paper examines the challenges of remote control delays in exoskeleton-aided physiotherapy. It focuses on the implications of telerehabilitation requirements for safe treatment. As the global share of disabled and elderly people increases, the demand for effective teleoperated physiotherapy solutions rises, necessitating precise control over robotic systems. The study utilizes a mixed-methods approach to assess delays in communication between a rehabilitation exoskeleton and the control system's based on the digital twin in VR (virtual reality) components at different stages. Moreover, additional delays coming from distant operations are assessed. Key findings reveal that the average latency for joint control on shorter distances remains below 300 ms-considered acceptable for comfortable manual teleoperation. The delays between setting the device's configuration and reaching it by a physical exoskeleton differ for particular joints and depend mainly on the torque-to-moment of inertia ratio. The total communication cycle should not exceed 400 ms, which can be further reduced by using a 6G network in the future or ADS (Automation Device Specification) communication protocol instead of the database. Ultimately, the study provides a foundation for developing algorithms that can mitigate delays and improve the efficacy of telehealth solutions with physically supportive devices.

30 October 2025
Verified
Book Chapter
Closed access
PDF file
KJKajetan Jeznach
Kajetan Jeznach
KHKrzysztof Hryniów
Krzysztof Hryniów

14 August 2026 in Acta Mechanica et Automatica
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
KJKajetan Jeznach
Kajetan Jeznach
TOTomasz Osiak
Tomasz Osiak
JOJan Oleksiuk
Jan Oleksiuk
KZKrzysztof Zawalski
Krzysztof Zawalski
TCTomasz Chomiuk
Tomasz Chomiuk
Population ageing, neurological and orthopaedical diseases, and shortages in medical staff result in the need to develop tools for minimally su-pervised therapy. To guarantee effective kinesiotherapy in high doses, rehabilitation robots are required. However, they require additional tech-nologies for automating treatment and monitoring patients' safety. This paper presents and assesses such technologies integrated with the SmartEx-Twin exoskeleton of a lower extremity and its digital twin in virtual reality (VR) for teleoperation during emergency cases. The intelligent algorithms were proven to increase the effectiveness of the therapy, as assessed based on the EMG measured. The VR system was validated as also increasing the effectiveness, but reducing the perception of tiring exercises, based on EEG tracking. Additionally, the accuracy of controlling exoskeleton movements was measured. It was found out that the poor operation skills of the physiotherapist in the VR environment can increase motion inaccuracies by as much as 30 degrees per joint. Additional emergency tools trig-gered by spastic cramps detected and risk of pain were assessed as fully reliable and working with the delay of up to 125 ms and 2 s, respec-tively. The whole system was implemented for the exoskeleton and will undergo further tests to minimize control inaccuracies and teleoperation delays.