Maciej Pikuliński

Mr. Maciej Pikuliński


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Mechanism and Machine Theory
Verified
Journal Article
Open access
MPMaciej Pikuliński
Maciej Pikuliński
PMPaweł Malczyk
Paweł Malczyk


15 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
PKPiotr Kołodziejski
Piotr Kołodziejski
KZKrzysztof Zawalski
Krzysztof Zawalski
MPMaciej Pikuliński
Maciej Pikuliński
JOJan Oleksiuk
Jan Oleksiuk
DŚDaniel Ireneusz Śliż
Daniel Ireneusz Śliż
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.

12 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
PKPiotr Kołodziejski
Piotr Kołodziejski
KZKrzysztof Zawalski
Krzysztof Zawalski
MPMaciej Pikuliński
Maciej Pikuliński
JOJan Oleksiuk
Jan Oleksiuk
DŚDaniel Ireneusz Śliż
Daniel Ireneusz Śliż
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.

1 September 2026 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
KJKajetan Jeznach
Kajetan Jeznach
JOJan Oleksiuk
Jan Oleksiuk
TOTomasz Osiak
Tomasz Osiak
MPMaciej Pikuliński
Maciej Pikuliński
DŚDaniel Ireneusz Śliż
Daniel Ireneusz Śliż
Background: Task-oriented rehabilitation supported by exoskeletons has the potential to increase therapy intensity, personalization, and accessibility. However, to achieve fully automatic treatment, robotized systems need to analyze therapy in a more complex way than only based on reference trajectories following. Objective: This study aimed to investigate the effects of an intelligent, context-aware control algorithm for an upper limb rehabilitation exoskeleton on patients’ musculoskeletal engagement, compared with constant-admittance robot-assisted therapy, and conventional physiotherapist-guided treatment. Methods: A single-session experimental study was conducted with 34 adult participants performing 6 activities of daily living under 3 therapy modes: robot-assisted therapy with constant admittance, robot-assisted therapy with an intelligent assist-as-needed algorithm, and physiotherapist-guided therapy. Muscle activity was assessed using surface electromyography of 8 upper limb muscle groups, while joint kinematics were recorded using inertial measurement units. Metrics included electromyography power, muscle activation time, joint range of motion, and Burst Duration Similarity Indices. Statistical comparisons were performed using the t test and the Mann-Whitney U test depending on data normality. Results: Results indicate that the intelligent control strategy engages the musculoskeletal system at least as effectively as constant-admittance control across all exercises. At the same time, more motion control is given to the patient, which is consistent with the principles of neuroplastic motor learning. Compared with physiotherapist-guided therapy, robot-assisted treatment with intelligent control elicited significantly higher and more consistent muscular engagement. Intelligent assistance also modified joint-level motion patterns by reducing compensatory movements, particularly in shoulder-elbow coupling, while maintaining functional task execution. Muscle activation timing patterns during intelligent robot-assisted therapy were more consistent with robotic control than with manual therapy, reflecting altered movement strategies. Conclusions: These findings demonstrate that context-aware, intelligent control in rehabilitation exoskeletons can promote active patient participation, reduce compensatory behaviors, and maintain physiologically meaningful muscle engagement. The proposed approach exceeds the results of recent similar studies, being a promising step toward effective, minimally supervised, and task-oriented rehabilitation.